Cargando…

Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life

Introduction/background: The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius frac...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsitsilonis, Serafim, Machó, David, Manegold, Sebastian, Krapohl, Björn Dirk, Wichlas, Florian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977376/
https://www.ncbi.nlm.nih.gov/pubmed/27547692
http://dx.doi.org/10.3205/iprs000099
_version_ 1782447015946354688
author Tsitsilonis, Serafim
Machó, David
Manegold, Sebastian
Krapohl, Björn Dirk
Wichlas, Florian
author_facet Tsitsilonis, Serafim
Machó, David
Manegold, Sebastian
Krapohl, Björn Dirk
Wichlas, Florian
author_sort Tsitsilonis, Serafim
collection PubMed
description Introduction/background: The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius fractures treated with the locking compression plate (LCP). Materials and methods: In the present study 128 patients (130 fractures) that were operatively treated with the LCP (2.4 mm/3.5 mm, Synthes(®)) were retrospectively evaluated. Mean follow-up was 22.7 months (SD 10.6). The fractures were radiographically evaluated (radial inclination, palmar tilt, ulnar variance) pre-, postoperatively and at the last follow-up visit. Range of motion (ROM) was documented. Grip strength was assessed with the use of a JAMAR dynamometer. The score for disabilities of the arm, shoulder and hand (DASH) and the Gartland-Werley score (GWS) were evaluated. Health-associated quality of life was assessed with use of SF-36 Health Survey. Results: Postoperative reduction was excellent; at the last follow-up visit only minimal reduction loss was observed. Except for pronation, a statistically significant decrease of ROM was present; in most cases that was not disturbing for the patients. The injured side achieved 83.9% of grip strength of the intact side. Mean DASH was 18.9 and mean GWS was 3.5. Health-associated quality of life was generally not compromised. However, limitations in ulnar abduction correlated with inferior quality of life. Fracture severity correlated with inferior quality of life, despite the absence of correlation with the functional and radiological outcome. Complication rate was low. Conclusions: Fracture severity seems to affect ulnar abduction and therefore patient quality of life, despite almost anatomical reduction; the objective and subjective scores were in most cases excellent. Modern everyday activities, such as keyboard typing, could be associated with the present results.
format Online
Article
Text
id pubmed-4977376
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-49773762016-08-19 Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life Tsitsilonis, Serafim Machó, David Manegold, Sebastian Krapohl, Björn Dirk Wichlas, Florian GMS Interdiscip Plast Reconstr Surg DGPW Article Introduction/background: The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius fractures treated with the locking compression plate (LCP). Materials and methods: In the present study 128 patients (130 fractures) that were operatively treated with the LCP (2.4 mm/3.5 mm, Synthes(®)) were retrospectively evaluated. Mean follow-up was 22.7 months (SD 10.6). The fractures were radiographically evaluated (radial inclination, palmar tilt, ulnar variance) pre-, postoperatively and at the last follow-up visit. Range of motion (ROM) was documented. Grip strength was assessed with the use of a JAMAR dynamometer. The score for disabilities of the arm, shoulder and hand (DASH) and the Gartland-Werley score (GWS) were evaluated. Health-associated quality of life was assessed with use of SF-36 Health Survey. Results: Postoperative reduction was excellent; at the last follow-up visit only minimal reduction loss was observed. Except for pronation, a statistically significant decrease of ROM was present; in most cases that was not disturbing for the patients. The injured side achieved 83.9% of grip strength of the intact side. Mean DASH was 18.9 and mean GWS was 3.5. Health-associated quality of life was generally not compromised. However, limitations in ulnar abduction correlated with inferior quality of life. Fracture severity correlated with inferior quality of life, despite the absence of correlation with the functional and radiological outcome. Complication rate was low. Conclusions: Fracture severity seems to affect ulnar abduction and therefore patient quality of life, despite almost anatomical reduction; the objective and subjective scores were in most cases excellent. Modern everyday activities, such as keyboard typing, could be associated with the present results. German Medical Science GMS Publishing House 2016-07-28 /pmc/articles/PMC4977376/ /pubmed/27547692 http://dx.doi.org/10.3205/iprs000099 Text en Copyright © 2016 Tsitsilonis et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.
spellingShingle Article
Tsitsilonis, Serafim
Machó, David
Manegold, Sebastian
Krapohl, Björn Dirk
Wichlas, Florian
Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title_full Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title_fullStr Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title_full_unstemmed Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title_short Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
title_sort fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977376/
https://www.ncbi.nlm.nih.gov/pubmed/27547692
http://dx.doi.org/10.3205/iprs000099
work_keys_str_mv AT tsitsilonisserafim fractureseverityofdistalradiusfracturestreatedwithlockingplatingcorrelateswithlimitationsinulnarabductionandinferiorhealthrelatedqualityoflife
AT machodavid fractureseverityofdistalradiusfracturestreatedwithlockingplatingcorrelateswithlimitationsinulnarabductionandinferiorhealthrelatedqualityoflife
AT manegoldsebastian fractureseverityofdistalradiusfracturestreatedwithlockingplatingcorrelateswithlimitationsinulnarabductionandinferiorhealthrelatedqualityoflife
AT krapohlbjorndirk fractureseverityofdistalradiusfracturestreatedwithlockingplatingcorrelateswithlimitationsinulnarabductionandinferiorhealthrelatedqualityoflife
AT wichlasflorian fractureseverityofdistalradiusfracturestreatedwithlockingplatingcorrelateswithlimitationsinulnarabductionandinferiorhealthrelatedqualityoflife