Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects

OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based convent...

Descripción completa

Detalles Bibliográficos
Autores principales: Bardal, Roghieh, Jahanihashemi, Hassan, Mostafavi, Maryam, Kalhor, Esmaeil, Tofangchiha, Maryam, Dehghani, Mahdieh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977403/
https://www.ncbi.nlm.nih.gov/pubmed/27507990
_version_ 1782447022096252928
author Bardal, Roghieh
Jahanihashemi, Hassan
Mostafavi, Maryam
Kalhor, Esmaeil
Tofangchiha, Maryam
Dehghani, Mahdieh
author_facet Bardal, Roghieh
Jahanihashemi, Hassan
Mostafavi, Maryam
Kalhor, Esmaeil
Tofangchiha, Maryam
Dehghani, Mahdieh
author_sort Bardal, Roghieh
collection PubMed
description OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. MATERIALS AND METHODS: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. RESULTS: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. CONCLUSION: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.
format Online
Article
Text
id pubmed-4977403
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-49774032016-08-09 Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects Bardal, Roghieh Jahanihashemi, Hassan Mostafavi, Maryam Kalhor, Esmaeil Tofangchiha, Maryam Dehghani, Mahdieh J Dent (Tehran) Original Article OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. MATERIALS AND METHODS: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. RESULTS: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. CONCLUSION: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills. Tehran University of Medical Sciences 2015-11 /pmc/articles/PMC4977403/ /pubmed/27507990 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Bardal, Roghieh
Jahanihashemi, Hassan
Mostafavi, Maryam
Kalhor, Esmaeil
Tofangchiha, Maryam
Dehghani, Mahdieh
Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title_full Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title_fullStr Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title_full_unstemmed Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title_short Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
title_sort accuracy of cone beam computed tomography, photostimulable phosphor plate digital radiography and conventional radiography for detection of artificial cancellous bone defects
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977403/
https://www.ncbi.nlm.nih.gov/pubmed/27507990
work_keys_str_mv AT bardalroghieh accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects
AT jahanihashemihassan accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects
AT mostafavimaryam accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects
AT kalhoresmaeil accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects
AT tofangchihamaryam accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects
AT dehghanimahdieh accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects