Cargando…
Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects
OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based convent...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977403/ https://www.ncbi.nlm.nih.gov/pubmed/27507990 |
_version_ | 1782447022096252928 |
---|---|
author | Bardal, Roghieh Jahanihashemi, Hassan Mostafavi, Maryam Kalhor, Esmaeil Tofangchiha, Maryam Dehghani, Mahdieh |
author_facet | Bardal, Roghieh Jahanihashemi, Hassan Mostafavi, Maryam Kalhor, Esmaeil Tofangchiha, Maryam Dehghani, Mahdieh |
author_sort | Bardal, Roghieh |
collection | PubMed |
description | OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. MATERIALS AND METHODS: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. RESULTS: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. CONCLUSION: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills. |
format | Online Article Text |
id | pubmed-4977403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-49774032016-08-09 Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects Bardal, Roghieh Jahanihashemi, Hassan Mostafavi, Maryam Kalhor, Esmaeil Tofangchiha, Maryam Dehghani, Mahdieh J Dent (Tehran) Original Article OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. MATERIALS AND METHODS: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. RESULTS: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. CONCLUSION: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills. Tehran University of Medical Sciences 2015-11 /pmc/articles/PMC4977403/ /pubmed/27507990 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Bardal, Roghieh Jahanihashemi, Hassan Mostafavi, Maryam Kalhor, Esmaeil Tofangchiha, Maryam Dehghani, Mahdieh Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title | Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title_full | Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title_fullStr | Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title_full_unstemmed | Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title_short | Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects |
title_sort | accuracy of cone beam computed tomography, photostimulable phosphor plate digital radiography and conventional radiography for detection of artificial cancellous bone defects |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977403/ https://www.ncbi.nlm.nih.gov/pubmed/27507990 |
work_keys_str_mv | AT bardalroghieh accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects AT jahanihashemihassan accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects AT mostafavimaryam accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects AT kalhoresmaeil accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects AT tofangchihamaryam accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects AT dehghanimahdieh accuracyofconebeamcomputedtomographyphotostimulablephosphorplatedigitalradiographyandconventionalradiographyfordetectionofartificialcancellousbonedefects |