Correcting motion in multiplanar cardiac magnetic resonance images

BACKGROUND: Misalignment in cardiac magnetic resonance (CMR) images can adversely affect three-dimensional left ventricle modelling and downstream quantitative analysis. Currently, there are two types of approaches for dealing with realignment and motion distortion problems, one image based and the...

Descripción completa

Detalles Bibliográficos
Autores principales: Wan, Min, Huang, Wei, Zhang, Jun-Mei, Zhao, Xiaodan, Allen, John Carson, Tan, Ru San, Wan, Xiaofeng, Zhong, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977636/
https://www.ncbi.nlm.nih.gov/pubmed/27503101
http://dx.doi.org/10.1186/s12938-016-0216-8
_version_ 1782447065756860416
author Wan, Min
Huang, Wei
Zhang, Jun-Mei
Zhao, Xiaodan
Allen, John Carson
Tan, Ru San
Wan, Xiaofeng
Zhong, Liang
author_facet Wan, Min
Huang, Wei
Zhang, Jun-Mei
Zhao, Xiaodan
Allen, John Carson
Tan, Ru San
Wan, Xiaofeng
Zhong, Liang
author_sort Wan, Min
collection PubMed
description BACKGROUND: Misalignment in cardiac magnetic resonance (CMR) images can adversely affect three-dimensional left ventricle modelling and downstream quantitative analysis. Currently, there are two types of approaches for dealing with realignment and motion distortion problems, one image based and the other geometry based. Image-based approaches are limited by the inherent non-homogeneity and anisotropy of CMR images. Geometry-based approaches rely on idealized models and over-simplified assumptions. This study was motivated by the need for a robust and effective approach for correcting motion related distortions due to misalignment in CMR images. METHODS: A cine cardiac magnetic resonance image sequence was acquired using our routine clinical imaging protocol. The left ventricular endocardium was delineated manually with software assistance on all long and short-axis images. Long and short-axis contours were projected onto a patient-based coordinate system and then realigned using iterative registration. The realigned contour points were used to reconstruct the shape of the left ventricle for quantitative validation. RESULTS: The method was tested on five myocardial infarction patients whose images showed substantial misalignment. Realignment time was about 16 seconds per case, using a 2.5 GHz CPU desktop with obvious elimination of the distortion in the reconstructed model. Using the long-axis contour as a reference in evaluating the reconstructed models, it was apparent that the models with realigned contours had better accuracy than the non-realigned ones. CONCLUSION: This study presents a novel, geometry-based method for correcting motion distortions in CMR images. The method incorporates (1) manual delineation, (2) registration based on a generalized, iterative closest point algorithm, and (3) reconstruction of the shape of the left ventricle for quantitative validation. The effectiveness of our approach is corroborated both visually and by quantitative assessment. We envision the use of our method in current clinical practice as a means of improving accuracy in the evaluation of cardiac function.
format Online
Article
Text
id pubmed-4977636
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-49776362016-08-10 Correcting motion in multiplanar cardiac magnetic resonance images Wan, Min Huang, Wei Zhang, Jun-Mei Zhao, Xiaodan Allen, John Carson Tan, Ru San Wan, Xiaofeng Zhong, Liang Biomed Eng Online Research BACKGROUND: Misalignment in cardiac magnetic resonance (CMR) images can adversely affect three-dimensional left ventricle modelling and downstream quantitative analysis. Currently, there are two types of approaches for dealing with realignment and motion distortion problems, one image based and the other geometry based. Image-based approaches are limited by the inherent non-homogeneity and anisotropy of CMR images. Geometry-based approaches rely on idealized models and over-simplified assumptions. This study was motivated by the need for a robust and effective approach for correcting motion related distortions due to misalignment in CMR images. METHODS: A cine cardiac magnetic resonance image sequence was acquired using our routine clinical imaging protocol. The left ventricular endocardium was delineated manually with software assistance on all long and short-axis images. Long and short-axis contours were projected onto a patient-based coordinate system and then realigned using iterative registration. The realigned contour points were used to reconstruct the shape of the left ventricle for quantitative validation. RESULTS: The method was tested on five myocardial infarction patients whose images showed substantial misalignment. Realignment time was about 16 seconds per case, using a 2.5 GHz CPU desktop with obvious elimination of the distortion in the reconstructed model. Using the long-axis contour as a reference in evaluating the reconstructed models, it was apparent that the models with realigned contours had better accuracy than the non-realigned ones. CONCLUSION: This study presents a novel, geometry-based method for correcting motion distortions in CMR images. The method incorporates (1) manual delineation, (2) registration based on a generalized, iterative closest point algorithm, and (3) reconstruction of the shape of the left ventricle for quantitative validation. The effectiveness of our approach is corroborated both visually and by quantitative assessment. We envision the use of our method in current clinical practice as a means of improving accuracy in the evaluation of cardiac function. BioMed Central 2016-08-08 /pmc/articles/PMC4977636/ /pubmed/27503101 http://dx.doi.org/10.1186/s12938-016-0216-8 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wan, Min
Huang, Wei
Zhang, Jun-Mei
Zhao, Xiaodan
Allen, John Carson
Tan, Ru San
Wan, Xiaofeng
Zhong, Liang
Correcting motion in multiplanar cardiac magnetic resonance images
title Correcting motion in multiplanar cardiac magnetic resonance images
title_full Correcting motion in multiplanar cardiac magnetic resonance images
title_fullStr Correcting motion in multiplanar cardiac magnetic resonance images
title_full_unstemmed Correcting motion in multiplanar cardiac magnetic resonance images
title_short Correcting motion in multiplanar cardiac magnetic resonance images
title_sort correcting motion in multiplanar cardiac magnetic resonance images
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4977636/
https://www.ncbi.nlm.nih.gov/pubmed/27503101
http://dx.doi.org/10.1186/s12938-016-0216-8
work_keys_str_mv AT wanmin correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT huangwei correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT zhangjunmei correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT zhaoxiaodan correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT allenjohncarson correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT tanrusan correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT wanxiaofeng correctingmotioninmultiplanarcardiacmagneticresonanceimages
AT zhongliang correctingmotioninmultiplanarcardiacmagneticresonanceimages