Cargando…

Effects of thermal fatigue on shear punch strength of tooth-colored restoratives

AIMS: This study investigated the effect of thermal fatigue on the shear strength of a range of tooth-colored restorative materials including giomers, zirconia-reinforced glass ionomer cement (GIC), nano-particle resin-modified GIC, highly viscous GICs, and composite resin. MATERIALS AND METHODS: Tw...

Descripción completa

Detalles Bibliográficos
Autores principales: Melody, Fam Mei Shi, U-Jin, Yap Adrian, Natalie, Tan Wei Min, Elizabeth, Tay Wan Ling, Chien, Jessica Yeo Siu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979280/
https://www.ncbi.nlm.nih.gov/pubmed/27563182
http://dx.doi.org/10.4103/0972-0707.186444
Descripción
Sumario:AIMS: This study investigated the effect of thermal fatigue on the shear strength of a range of tooth-colored restorative materials including giomers, zirconia-reinforced glass ionomer cement (GIC), nano-particle resin-modified GIC, highly viscous GICs, and composite resin. MATERIALS AND METHODS: Twenty specimens of each material were fabricated in standardized washers (17 mm outer diameter, 9 mm internal diameter, 1 mm thick). The specimens were cured, stored in 100% humidity at 37.5°C for 24 h, and randomly divided into two groups of 10. Group A specimens were nonthermocycled (NT) and stored in distilled water at 37°C for 168 h. Group B specimens were thermocycled (TC) for 10,000 cycles (168 h) with baths X, Y, and Z adjusted to 35°C, 15°C, and 45°C, respectively. Each cycle had dwell times of 28 s in X, and 2s in Y/Z in the order XYXZ. Specimens then underwent shear punch testing at a crosshead speed of 0.5 mm/min with a 2 kN load cell. Statistical analysis of shear strength was done using t-test and two-way ANOVA/Scheffe's post hoc test at significance level P < 0.05. RESULTS: The effect of thermal fatigue on shear strength was material dependent. Except for the “sculptable” giomer (Beautifil II) and a highly viscous GIC (Fuji IX GP Fast), no significant differences in shear strength were generally observed between the NT and TC groups. For both groups, the composite resin (Filtek Z250XT) had the highest shear strength while the zirconia-reinforced (zirconomer) and a highly viscous GIC (Ketac Molar Quick) had the lowest. CONCLUSIONS: The effect of thermocycling on shear strength was material dependent. Thermal fatigue, however, did not significantly influence the shear strength of most materials assessed. The “sculptable” composite and giomer were significantly stronger than the other materials evaluated. Shear strength of the “flowable” injectable hybrid giomer was intermediate between the composite and GICs.