Cargando…

The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery

BACKGROUND: The use of intraoperative pulse oximetry (Spo(2)) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, Spo(2) may be reported as 98% when arterial partial pressure of oxygen (Pao(2)) is as low as 70 mm Hg. Therefore, Spo(2) may not provide advanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Applegate, Richard L., Dorotta, Ihab L., Wells, Briana, Juma, David, Applegate, Patricia M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2016
Materias:
8
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979626/
https://www.ncbi.nlm.nih.gov/pubmed/27007078
http://dx.doi.org/10.1213/ANE.0000000000001262
Descripción
Sumario:BACKGROUND: The use of intraoperative pulse oximetry (Spo(2)) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, Spo(2) may be reported as 98% when arterial partial pressure of oxygen (Pao(2)) is as low as 70 mm Hg. Therefore, Spo(2) may not provide advance warning of falling arterial oxygenation until Pao(2) approaches this level. Multiwave pulse co-oximetry can provide a calculated oxygen reserve index (ORI) that may add to information from pulse oximetry when Spo(2) is >98%. This study evaluates the ORI to Pao(2) relationship during surgery. METHODS: We studied patients undergoing scheduled surgery in which arterial catheterization and intraoperative arterial blood gas analysis were planned. Data from multiple pulse co-oximetry sensors on each patient were continuously collected and stored on a research computer. Regression analysis was used to compare ORI with Pao(2) obtained from each arterial blood gas measurement and changes in ORI with changes in Pao(2) from sequential measurements. Linear mixed-effects regression models for repeated measures were then used to account for within-subject correlation across the repeatedly measured Pao(2) and ORI and for the unequal time intervals of Pao(2) determination over elapsed surgical time. Regression plots were inspected for ORI values corresponding to Pao(2) of 100 and 150 mm Hg. ORI and Pao(2) were compared using mixed-effects models with a subject-specific random intercept. RESULTS: ORI values and Pao(2) measurements were obtained from intraoperative data collected from 106 patients. Regression analysis showed that the ORI to Pao(2) relationship was stronger for Pao(2) to 240 mm Hg (r(2) = 0.536) than for Pao(2) over 240 mm Hg (r(2) = 0.0016). Measured Pao(2) was ≥100 mm Hg for all ORI over 0.24. Measured Pao(2) was ≥150 mm Hg in 96.6% of samples when ORI was over 0.55. A random intercept variance component linear mixed-effects model for repeated measures indicated that Pao(2) was significantly related to ORI (β[95% confidence interval] = 0.002 [0.0019–0.0022]; P < 0.0001). A similar analysis indicated a significant relationship between change in Pao(2) and change in ORI (β [95% confidence interval] = 0.0044 [0.0040–0.0048]; P < 0.0001). CONCLUSIONS: These findings suggest that ORI >0.24 can distinguish Pao(2) ≥100 mm Hg when Spo(2) is over 98%. Similarly, ORI > 0.55 appears to be a threshold to distinguish Pao(2) ≥150 mm Hg. The usefulness of these values should be evaluated prospectively. Decreases in ORI to near 0.24 may provide advance indication of falling Pao(2) approaching 100 mm Hg when Spo(2) is >98%. The clinical utility of interventions based on continuous ORI monitoring should be studied prospectively.