Cargando…
High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angiopl...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979854/ https://www.ncbi.nlm.nih.gov/pubmed/27495100 http://dx.doi.org/10.1097/MD.0000000000004501 |
_version_ | 1782447390436884480 |
---|---|
author | Huang, Ching-Hui Kuo, Chen-Ling Huang, Ching-Shan Tseng, Wan-Min Lian, Ie Bin Chang, Chia-Chu Liu, Chin-San |
author_facet | Huang, Ching-Hui Kuo, Chen-Ling Huang, Ching-Shan Tseng, Wan-Min Lian, Ie Bin Chang, Chia-Chu Liu, Chin-San |
author_sort | Huang, Ching-Hui |
collection | PubMed |
description | Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction. |
format | Online Article Text |
id | pubmed-4979854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-49798542016-08-18 High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction Huang, Ching-Hui Kuo, Chen-Ling Huang, Ching-Shan Tseng, Wan-Min Lian, Ie Bin Chang, Chia-Chu Liu, Chin-San Medicine (Baltimore) 3400 Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction. Wolters Kluwer Health 2016-08-07 /pmc/articles/PMC4979854/ /pubmed/27495100 http://dx.doi.org/10.1097/MD.0000000000004501 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 3400 Huang, Ching-Hui Kuo, Chen-Ling Huang, Ching-Shan Tseng, Wan-Min Lian, Ie Bin Chang, Chia-Chu Liu, Chin-San High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title | High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title_full | High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title_fullStr | High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title_full_unstemmed | High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title_short | High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
title_sort | high plasma coenzyme q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979854/ https://www.ncbi.nlm.nih.gov/pubmed/27495100 http://dx.doi.org/10.1097/MD.0000000000004501 |
work_keys_str_mv | AT huangchinghui highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT kuochenling highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT huangchingshan highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT tsengwanmin highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT lianiebin highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT changchiachu highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction AT liuchinsan highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction |