Cargando…

High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction

Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angiopl...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Ching-Hui, Kuo, Chen-Ling, Huang, Ching-Shan, Tseng, Wan-Min, Lian, Ie Bin, Chang, Chia-Chu, Liu, Chin-San
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979854/
https://www.ncbi.nlm.nih.gov/pubmed/27495100
http://dx.doi.org/10.1097/MD.0000000000004501
_version_ 1782447390436884480
author Huang, Ching-Hui
Kuo, Chen-Ling
Huang, Ching-Shan
Tseng, Wan-Min
Lian, Ie Bin
Chang, Chia-Chu
Liu, Chin-San
author_facet Huang, Ching-Hui
Kuo, Chen-Ling
Huang, Ching-Shan
Tseng, Wan-Min
Lian, Ie Bin
Chang, Chia-Chu
Liu, Chin-San
author_sort Huang, Ching-Hui
collection PubMed
description Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction.
format Online
Article
Text
id pubmed-4979854
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-49798542016-08-18 High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction Huang, Ching-Hui Kuo, Chen-Ling Huang, Ching-Shan Tseng, Wan-Min Lian, Ie Bin Chang, Chia-Chu Liu, Chin-San Medicine (Baltimore) 3400 Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction. Wolters Kluwer Health 2016-08-07 /pmc/articles/PMC4979854/ /pubmed/27495100 http://dx.doi.org/10.1097/MD.0000000000004501 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 3400
Huang, Ching-Hui
Kuo, Chen-Ling
Huang, Ching-Shan
Tseng, Wan-Min
Lian, Ie Bin
Chang, Chia-Chu
Liu, Chin-San
High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title_full High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title_fullStr High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title_full_unstemmed High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title_short High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
title_sort high plasma coenzyme q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction
topic 3400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4979854/
https://www.ncbi.nlm.nih.gov/pubmed/27495100
http://dx.doi.org/10.1097/MD.0000000000004501
work_keys_str_mv AT huangchinghui highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT kuochenling highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT huangchingshan highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT tsengwanmin highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT lianiebin highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT changchiachu highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction
AT liuchinsan highplasmacoenzymeq10concentrationiscorrelatedwithgoodleftventricularperformanceafterprimaryangioplastyinpatientswithacutemyocardialinfarction