The relationship between the bone characters obtained by CBCT and primary stability of the implants
BACKGROUND: The aim of this study is to investigate the correlation between the thickness of the cortical bone or the voxel values that are obtained by cone beam CT (CBCT) and the insertion torque values (ITVs) or the implant stability quotient (ISQ) values. METHODS: A pig's ilium was used as t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981004/ https://www.ncbi.nlm.nih.gov/pubmed/27747625 http://dx.doi.org/10.1186/s40729-014-0003-x |
_version_ | 1782447555388375040 |
---|---|
author | Wada, Masahiro Tsuiki, Yasutane Suganami, Tohru Ikebe, Kazunori Sogo, Motofumi Okuno, Ikuhisa Maeda, Yoshinobu |
author_facet | Wada, Masahiro Tsuiki, Yasutane Suganami, Tohru Ikebe, Kazunori Sogo, Motofumi Okuno, Ikuhisa Maeda, Yoshinobu |
author_sort | Wada, Masahiro |
collection | PubMed |
description | BACKGROUND: The aim of this study is to investigate the correlation between the thickness of the cortical bone or the voxel values that are obtained by cone beam CT (CBCT) and the insertion torque values (ITVs) or the implant stability quotient (ISQ) values. METHODS: A pig's ilium was used as the implant placement site. The implants used in this study were two kinds of diameters (3.8 mm, 5.0 mm) and two kinds of lengths (7.0 mm, 12.0 mm) having a general threadlike shape with a mechanically polished surface. To measure the bone density and the cortical thickness around the implants accurately, the CBCT scanning was performed immediately just after the formation of the implant cavity. The initial stabilities were evaluated by the ITVs and the ISQ values. The bone density and cortical thickness around the implants were measured by an implant simulation software (Landmarker ver. 5.0 with special specifications for this study). The relationships of the thickness of the cortical bone and the voxel values with the ITVs and the ISQ values were analyzed using Pearson's correlation coefficient. To evaluate the influence on the ITVs and the ISQ values among multiple factors, multiple regression analysis was performed. P < 0.05 was considered statistically significant. RESULTS: A significant positive correlation was found between the thickness of the cortical bone and the ITVs or the ISQ values in all kinds of implants. In addition, a significant positive correlation was also found between the voxel values and the ITVs. From the multiple regression analysis, the thickness of the cortical bone and the voxel values had a positive influence on the ITVs and the ISQ values. In addition, the length of the implant had a positive influence on the ISQ values at the 3.8-mm-diameter implant. CONCLUSIONS: In this limited study, there were correlations between the thickness of the cortical bone or the voxel values obtained from the CBCT scanning and the implant stabilities. Besides, it was confirmed that the thickness of the cortical bone, the voxel value, and the implant length had positive correlations with the ITVs and the ISQ values. |
format | Online Article Text |
id | pubmed-4981004 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-49810042016-08-30 The relationship between the bone characters obtained by CBCT and primary stability of the implants Wada, Masahiro Tsuiki, Yasutane Suganami, Tohru Ikebe, Kazunori Sogo, Motofumi Okuno, Ikuhisa Maeda, Yoshinobu Int J Implant Dent Original Research BACKGROUND: The aim of this study is to investigate the correlation between the thickness of the cortical bone or the voxel values that are obtained by cone beam CT (CBCT) and the insertion torque values (ITVs) or the implant stability quotient (ISQ) values. METHODS: A pig's ilium was used as the implant placement site. The implants used in this study were two kinds of diameters (3.8 mm, 5.0 mm) and two kinds of lengths (7.0 mm, 12.0 mm) having a general threadlike shape with a mechanically polished surface. To measure the bone density and the cortical thickness around the implants accurately, the CBCT scanning was performed immediately just after the formation of the implant cavity. The initial stabilities were evaluated by the ITVs and the ISQ values. The bone density and cortical thickness around the implants were measured by an implant simulation software (Landmarker ver. 5.0 with special specifications for this study). The relationships of the thickness of the cortical bone and the voxel values with the ITVs and the ISQ values were analyzed using Pearson's correlation coefficient. To evaluate the influence on the ITVs and the ISQ values among multiple factors, multiple regression analysis was performed. P < 0.05 was considered statistically significant. RESULTS: A significant positive correlation was found between the thickness of the cortical bone and the ITVs or the ISQ values in all kinds of implants. In addition, a significant positive correlation was also found between the voxel values and the ITVs. From the multiple regression analysis, the thickness of the cortical bone and the voxel values had a positive influence on the ITVs and the ISQ values. In addition, the length of the implant had a positive influence on the ISQ values at the 3.8-mm-diameter implant. CONCLUSIONS: In this limited study, there were correlations between the thickness of the cortical bone or the voxel values obtained from the CBCT scanning and the implant stabilities. Besides, it was confirmed that the thickness of the cortical bone, the voxel value, and the implant length had positive correlations with the ITVs and the ISQ values. Springer Berlin Heidelberg 2015-02-12 /pmc/articles/PMC4981004/ /pubmed/27747625 http://dx.doi.org/10.1186/s40729-014-0003-x Text en © Wada et al.; licensee Springer. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Original Research Wada, Masahiro Tsuiki, Yasutane Suganami, Tohru Ikebe, Kazunori Sogo, Motofumi Okuno, Ikuhisa Maeda, Yoshinobu The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title | The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title_full | The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title_fullStr | The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title_full_unstemmed | The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title_short | The relationship between the bone characters obtained by CBCT and primary stability of the implants |
title_sort | relationship between the bone characters obtained by cbct and primary stability of the implants |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981004/ https://www.ncbi.nlm.nih.gov/pubmed/27747625 http://dx.doi.org/10.1186/s40729-014-0003-x |
work_keys_str_mv | AT wadamasahiro therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT tsuikiyasutane therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT suganamitohru therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT ikebekazunori therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT sogomotofumi therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT okunoikuhisa therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT maedayoshinobu therelationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT wadamasahiro relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT tsuikiyasutane relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT suganamitohru relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT ikebekazunori relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT sogomotofumi relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT okunoikuhisa relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants AT maedayoshinobu relationshipbetweenthebonecharactersobtainedbycbctandprimarystabilityoftheimplants |