Extracorporeal Cardiopulmonary Resuscitation: Predictors of Survival

BACKGROUND: The use of extracorporeal life support (ECLS) in the setting of cardiopulmonary resuscitation (CPR) has shown improved outcomes compared with conventional CPR. The aim of this study was to determine factors predictive of survival in extracorporeal CPR (E-CPR). METHODS: Consecutive 85 adu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dong Hee, Kim, Joon Bum, Jung, Sung-Ho, Choo, Suk Jung, Chung, Cheol Hyun, Lee, Jae Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Thoracic and Cardiovascular Surgery 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981229/
https://www.ncbi.nlm.nih.gov/pubmed/27525236
http://dx.doi.org/10.5090/kjtcs.2016.49.4.273
Descripción
Sumario:BACKGROUND: The use of extracorporeal life support (ECLS) in the setting of cardiopulmonary resuscitation (CPR) has shown improved outcomes compared with conventional CPR. The aim of this study was to determine factors predictive of survival in extracorporeal CPR (E-CPR). METHODS: Consecutive 85 adult patients (median age, 59 years; range, 18 to 85 years; 56 males) who underwent E-CPR from May 2005 to December 2012 were evaluated. RESULTS: Causes of arrest were cardiogenic in 62 patients (72.9%), septic in 18 patients (21.2%), and hypovolemic in 3 patients (3.5%), while the etiology was not specified in 2 patients (2.4%). The survival rate in patients with septic etiology was significantly poorer compared with those with another etiology (0% vs. 24.6%, p=0.008). Septic etiology (hazard ratio [HR], 2.84; 95% confidence interval [CI], 1.49 to 5.44; p=0.002) and the interval between arrest and ECLS initiation (HR, 1.05 by 10 minutes increment; 95% CI, 1.02 to 1.09; p=0.005) were independent risk factors for mortality. When the predictive value of the E-CPR timing for in-hospital mortality was assessed using the receiver operating characteristic curve method, the greatest accuracy was obtained at a cutoff of 60.5 minutes (area under the curve, 0.67; 95% CI, 0.54 to 0.80; p=0.032) with 47.8% sensitivity and 88.9% specificity. The survival rate was significantly different according to the cutoff of 60.5 minutes (p=0.001). CONCLUSION: These results indicate that efforts should be made to minimize the time between arrest and ECLS application, optimally within 60 minutes. In addition, E-CPR in patients with septic etiology showed grave outcomes, suggesting it to be of questionable benefit in these patients.