Cargando…

A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography

PURPOSE: We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. METHODS: Two hundred sixty-six pha...

Descripción completa

Detalles Bibliográficos
Autores principales: Zamir, Ehud, Kong, George Y.X., Kowalski, Tanya, Coote, Michael, Ang, Ghee Soon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981489/
https://www.ncbi.nlm.nih.gov/pubmed/27540496
http://dx.doi.org/10.1167/tvst.5.4.10
_version_ 1782447625437446144
author Zamir, Ehud
Kong, George Y.X.
Kowalski, Tanya
Coote, Michael
Ang, Ghee Soon
author_facet Zamir, Ehud
Kong, George Y.X.
Kowalski, Tanya
Coote, Michael
Ang, Ghee Soon
author_sort Zamir, Ehud
collection PubMed
description PURPOSE: We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. METHODS: Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance (“E”) and (2) lateral photographic temporal limbus to cornea distance (“Z”). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. RESULTS: A strong linear correlation was found between EZR and ACD, R = −0.91, R(2) = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was −0.013 mm (range −0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. CONCLUSIONS: Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. TRANSLATIONAL RELEVANCE: EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations.
format Online
Article
Text
id pubmed-4981489
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-49814892016-08-18 A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography Zamir, Ehud Kong, George Y.X. Kowalski, Tanya Coote, Michael Ang, Ghee Soon Transl Vis Sci Technol Articles PURPOSE: We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. METHODS: Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance (“E”) and (2) lateral photographic temporal limbus to cornea distance (“Z”). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. RESULTS: A strong linear correlation was found between EZR and ACD, R = −0.91, R(2) = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was −0.013 mm (range −0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. CONCLUSIONS: Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. TRANSLATIONAL RELEVANCE: EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations. The Association for Research in Vision and Ophthalmology 2016-07-29 /pmc/articles/PMC4981489/ /pubmed/27540496 http://dx.doi.org/10.1167/tvst.5.4.10 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Zamir, Ehud
Kong, George Y.X.
Kowalski, Tanya
Coote, Michael
Ang, Ghee Soon
A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title_full A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title_fullStr A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title_full_unstemmed A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title_short A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
title_sort novel method of quantitative anterior chamber depth estimation using temporal perpendicular digital photography
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4981489/
https://www.ncbi.nlm.nih.gov/pubmed/27540496
http://dx.doi.org/10.1167/tvst.5.4.10
work_keys_str_mv AT zamirehud anovelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT konggeorgeyx anovelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT kowalskitanya anovelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT cootemichael anovelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT anggheesoon anovelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT zamirehud novelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT konggeorgeyx novelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT kowalskitanya novelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT cootemichael novelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography
AT anggheesoon novelmethodofquantitativeanteriorchamberdepthestimationusingtemporalperpendiculardigitalphotography