Cargando…

Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?

BACKGROUND: Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac...

Descripción completa

Detalles Bibliográficos
Autores principales: Dahl, Michael, Hayes, Chris, Steen Rasmussen, Bodil, Larsson, Anders, Secher, Niels H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4982018/
https://www.ncbi.nlm.nih.gov/pubmed/27515038
http://dx.doi.org/10.1186/s12871-016-0224-z
Descripción
Sumario:BACKGROUND: Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac output (CO). This study tested that hypothesis in healthy volunteers exposed to central hypovolemia by head-up tilt. METHODS: Thirteen healthy volunteers were exposed to central hypovolemia by 45° head-up tilt while breathing through a facemask with 7.5 cmH(2)O inspiratory and/or expiratory resistors. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation (SPV), pulse pressure variation and stroke volume variation . Pulse contour analysis determined stroke volume (SV) and CO and we evaluated whether APV could detect a 10 % decrease in CO. RESULTS: During head-up tilt SV decreased form 91 (±46) to 55 (±24) mL (mean ± SD) and CO from 5.8 (±2.9) to 4.0 (±1.8) L/min (p < 0.05), while heart rate increased (65 (±11) to 75 (±13) bpm; P < 0.05). Systolic pressure decreased from 127 (±14) to 121 (±13) mmHg during head-up tilt, while SPV tended to increase (from 21 (±15)% to 30 (±13)%). Yet during head-up tilt, a SPV ≥ 37 % predicted a decrease in CO ≥ 10 % with a sensitivity and specificity of 78 % and 100 %, respectively. CONCLUSION: In spontaneously breathing healthy volunteers combined inspiratory and expiratory resistors enhance SPV during head-up tilted induced central hypovolemia and allow identifying a 10 % reduction in CO. Applying inspiratory and expiratory resistors might detect a fluid deficit in spontaneously breathing patients. TRIAL REGISTRATION: ClinicalTrials.gov number NCT02549482 Registered September 10(th) 2015.