Cargando…

Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial

OBJECTIVES: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file inst...

Descripción completa

Detalles Bibliográficos
Autores principales: Kashefinejad, Mohamad, Harandi, Azade, Eram, Saeed, Bijani, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4983560/
https://www.ncbi.nlm.nih.gov/pubmed/27536323
_version_ 1782447913706717184
author Kashefinejad, Mohamad
Harandi, Azade
Eram, Saeed
Bijani, Ali
author_facet Kashefinejad, Mohamad
Harandi, Azade
Eram, Saeed
Bijani, Ali
author_sort Kashefinejad, Mohamad
collection PubMed
description OBJECTIVES: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. MATERIALS AND METHODS: In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student’s t-test (P<0.05). RESULTS: Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). CONCLUSIONS: The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.
format Online
Article
Text
id pubmed-4983560
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-49835602016-08-17 Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial Kashefinejad, Mohamad Harandi, Azade Eram, Saeed Bijani, Ali J Dent (Tehran) Original Article OBJECTIVES: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. MATERIALS AND METHODS: In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student’s t-test (P<0.05). RESULTS: Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). CONCLUSIONS: The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files. Tehran University of Medical Sciences 2016-01 /pmc/articles/PMC4983560/ /pubmed/27536323 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Kashefinejad, Mohamad
Harandi, Azade
Eram, Saeed
Bijani, Ali
Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title_full Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title_fullStr Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title_full_unstemmed Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title_short Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial
title_sort comparison of single visit post endodontic pain using mtwo rotary and hand k-file instruments: a randomized clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4983560/
https://www.ncbi.nlm.nih.gov/pubmed/27536323
work_keys_str_mv AT kashefinejadmohamad comparisonofsinglevisitpostendodonticpainusingmtworotaryandhandkfileinstrumentsarandomizedclinicaltrial
AT harandiazade comparisonofsinglevisitpostendodonticpainusingmtworotaryandhandkfileinstrumentsarandomizedclinicaltrial
AT eramsaeed comparisonofsinglevisitpostendodonticpainusingmtworotaryandhandkfileinstrumentsarandomizedclinicaltrial
AT bijaniali comparisonofsinglevisitpostendodonticpainusingmtworotaryandhandkfileinstrumentsarandomizedclinicaltrial