Cargando…

A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver

Patent foramen ovale (PFO) is a remnant of the fetal circulation exist in 20% of the general population. The purpose of our study was to compare of transthoracic echocardiography (TTE) and contrast-transcranial Doppler sonography (c-TCD) in the diagnosis and quantification of PFO with or without the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Enfa, Wei, Yajuan, Zhang, Yafei, Zhai, Nina, Zhao, Ping, Liu, Baomin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4985435/
https://www.ncbi.nlm.nih.gov/pubmed/26512622
http://dx.doi.org/10.1097/MD.0000000000001937
_version_ 1782448068171399168
author Zhao, Enfa
Wei, Yajuan
Zhang, Yafei
Zhai, Nina
Zhao, Ping
Liu, Baomin
author_facet Zhao, Enfa
Wei, Yajuan
Zhang, Yafei
Zhai, Nina
Zhao, Ping
Liu, Baomin
author_sort Zhao, Enfa
collection PubMed
description Patent foramen ovale (PFO) is a remnant of the fetal circulation exist in 20% of the general population. The purpose of our study was to compare of transthoracic echocardiography (TTE) and contrast-transcranial Doppler sonography (c-TCD) in the diagnosis and quantification of PFO with or without the Valsalva maneuver (VM). We studied 106 patients with a high clinical suspicion for PFO prospectively. Simultaneous c-TCD and TTE were conducted using agitated saline solution to detect right to left shunt (RLS). To classify RLS, mainly PFO, we applied a 4-level visual classification for c-TCD test: no occurrence of micro-embolic signals; grade I, 1 to 10 signals; grade II, 10 to 30 signals but not curtain; and grade III, curtain pattern. We used the number of micro-bubbles appeared in left atrium per frame image to define classification for TTE test: no occurrence of micro-bubbles; grade I, 1 to 10 micro-bubbles; grade II, 10 to 30 micro-bubbles; and grade III, more than 30 micro-bubbles or left atrium nearly filled with micro-bubbles or left atrial opacity. Statistical analyses were performed using SPSS Version 18.0. RLS was detected in 36.0% in c-TCD test and in 46% in TTE test at rest (P = 0.158). And during the VM, RLS was detected in 99.0% in c-TCD test and in 83.0% in TTE test (P < 0.001). Compared with the positive results of c-TCD and TTE at rest, the positive results of them with VM is more higher, respectively (all P < 0.001). The VM obviously increased the number of micro-bubbles shunting. Both c-TCD and TTE should used as initial screening tool for PFO. VM increases the size of shunt. VM resulted in detection of more RLS both in c-TCD and TTE tests.
format Online
Article
Text
id pubmed-4985435
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-49854352016-08-26 A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver Zhao, Enfa Wei, Yajuan Zhang, Yafei Zhai, Nina Zhao, Ping Liu, Baomin Medicine (Baltimore) 4100 Patent foramen ovale (PFO) is a remnant of the fetal circulation exist in 20% of the general population. The purpose of our study was to compare of transthoracic echocardiography (TTE) and contrast-transcranial Doppler sonography (c-TCD) in the diagnosis and quantification of PFO with or without the Valsalva maneuver (VM). We studied 106 patients with a high clinical suspicion for PFO prospectively. Simultaneous c-TCD and TTE were conducted using agitated saline solution to detect right to left shunt (RLS). To classify RLS, mainly PFO, we applied a 4-level visual classification for c-TCD test: no occurrence of micro-embolic signals; grade I, 1 to 10 signals; grade II, 10 to 30 signals but not curtain; and grade III, curtain pattern. We used the number of micro-bubbles appeared in left atrium per frame image to define classification for TTE test: no occurrence of micro-bubbles; grade I, 1 to 10 micro-bubbles; grade II, 10 to 30 micro-bubbles; and grade III, more than 30 micro-bubbles or left atrium nearly filled with micro-bubbles or left atrial opacity. Statistical analyses were performed using SPSS Version 18.0. RLS was detected in 36.0% in c-TCD test and in 46% in TTE test at rest (P = 0.158). And during the VM, RLS was detected in 99.0% in c-TCD test and in 83.0% in TTE test (P < 0.001). Compared with the positive results of c-TCD and TTE at rest, the positive results of them with VM is more higher, respectively (all P < 0.001). The VM obviously increased the number of micro-bubbles shunting. Both c-TCD and TTE should used as initial screening tool for PFO. VM increases the size of shunt. VM resulted in detection of more RLS both in c-TCD and TTE tests. Wolters Kluwer Health 2015-10-30 /pmc/articles/PMC4985435/ /pubmed/26512622 http://dx.doi.org/10.1097/MD.0000000000001937 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 4100
Zhao, Enfa
Wei, Yajuan
Zhang, Yafei
Zhai, Nina
Zhao, Ping
Liu, Baomin
A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title_full A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title_fullStr A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title_full_unstemmed A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title_short A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver
title_sort comparison of transthroracic echocardiograpy and transcranial doppler with contrast agent for detection of patent foramen ovale with or without the valsalva maneuver
topic 4100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4985435/
https://www.ncbi.nlm.nih.gov/pubmed/26512622
http://dx.doi.org/10.1097/MD.0000000000001937
work_keys_str_mv AT zhaoenfa acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT weiyajuan acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhangyafei acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhainina acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhaoping acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT liubaomin acomparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhaoenfa comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT weiyajuan comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhangyafei comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhainina comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT zhaoping comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver
AT liubaomin comparisonoftransthroracicechocardiograpyandtranscranialdopplerwithcontrastagentfordetectionofpatentforamenovalewithorwithoutthevalsalvamaneuver