Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4986111/ https://www.ncbi.nlm.nih.gov/pubmed/27610156 |
_version_ | 1782448151480762368 |
---|---|
author | Sadeghi, Ramezan Kobarfard, Farzad Yazdanpanah, Hassan Eslamizad, Samira Bayat, Mitra |
author_facet | Sadeghi, Ramezan Kobarfard, Farzad Yazdanpanah, Hassan Eslamizad, Samira Bayat, Mitra |
author_sort | Sadeghi, Ramezan |
collection | PubMed |
description | Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (10.00 mL) by Hamilton syringe. After centrifugation, 500 µL of the lower organic phase was dried under a gentle stream of nitrogen, re-dissolved in chloroform and injected into GC-MS. Chloroform and acetone were found to be the best extraction and disperser solvent, respectively. Validation of the method was performed using spiked calibration curves. The enrichment factor ranged from 93 to 129 and the recovery ranged from 71 to 90%. The linear ranges for all the PAHs were 0.10-2.80 ngmL(-1). The relative standard deviations (RSDs) of PAHs in water by using anthracene-d(10 )as internal standard, were in the range of 4-11% for most of the analytes (n = 3). Limit of detection (LOD) for different PAHs were between 0.03 and 0.1 ngmL(-1). The method was successfully applied for the analysis of PAHs in mineral water samples collected from Tehran. |
format | Online Article Text |
id | pubmed-4986111 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-49861112016-09-08 Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS Sadeghi, Ramezan Kobarfard, Farzad Yazdanpanah, Hassan Eslamizad, Samira Bayat, Mitra Iran J Pharm Res Original Article Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (10.00 mL) by Hamilton syringe. After centrifugation, 500 µL of the lower organic phase was dried under a gentle stream of nitrogen, re-dissolved in chloroform and injected into GC-MS. Chloroform and acetone were found to be the best extraction and disperser solvent, respectively. Validation of the method was performed using spiked calibration curves. The enrichment factor ranged from 93 to 129 and the recovery ranged from 71 to 90%. The linear ranges for all the PAHs were 0.10-2.80 ngmL(-1). The relative standard deviations (RSDs) of PAHs in water by using anthracene-d(10 )as internal standard, were in the range of 4-11% for most of the analytes (n = 3). Limit of detection (LOD) for different PAHs were between 0.03 and 0.1 ngmL(-1). The method was successfully applied for the analysis of PAHs in mineral water samples collected from Tehran. Shaheed Beheshti University of Medical Sciences 2016 /pmc/articles/PMC4986111/ /pubmed/27610156 Text en © 2016 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sadeghi, Ramezan Kobarfard, Farzad Yazdanpanah, Hassan Eslamizad, Samira Bayat, Mitra Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title | Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title_full | Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title_fullStr | Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title_full_unstemmed | Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title_short | Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS |
title_sort | validation of an analytical method for determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and gc-ms |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4986111/ https://www.ncbi.nlm.nih.gov/pubmed/27610156 |
work_keys_str_mv | AT sadeghiramezan validationofananalyticalmethodfordeterminationof13prioritypolycyclicaromatichydrocarbonsinmineralwaterusingdispersiveliquidliquidmicroextractionandgcms AT kobarfardfarzad validationofananalyticalmethodfordeterminationof13prioritypolycyclicaromatichydrocarbonsinmineralwaterusingdispersiveliquidliquidmicroextractionandgcms AT yazdanpanahhassan validationofananalyticalmethodfordeterminationof13prioritypolycyclicaromatichydrocarbonsinmineralwaterusingdispersiveliquidliquidmicroextractionandgcms AT eslamizadsamira validationofananalyticalmethodfordeterminationof13prioritypolycyclicaromatichydrocarbonsinmineralwaterusingdispersiveliquidliquidmicroextractionandgcms AT bayatmitra validationofananalyticalmethodfordeterminationof13prioritypolycyclicaromatichydrocarbonsinmineralwaterusingdispersiveliquidliquidmicroextractionandgcms |