Cargando…

Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring

Transcranial motor evoked potentials (TcMEPs), which are muscle action potentials elicited by transcranial brain stimulation, have been the most popular method for the last decade to monitor the functional integrity of the motor system during surgery. It was originally difficult to record reliable a...

Descripción completa

Detalles Bibliográficos
Autores principales: TSUTSUI, Shunji, YAMADA, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4987444/
https://www.ncbi.nlm.nih.gov/pubmed/26935781
http://dx.doi.org/10.2176/nmc.ra.2015-0307
_version_ 1782448304915742720
author TSUTSUI, Shunji
YAMADA, Hiroshi
author_facet TSUTSUI, Shunji
YAMADA, Hiroshi
author_sort TSUTSUI, Shunji
collection PubMed
description Transcranial motor evoked potentials (TcMEPs), which are muscle action potentials elicited by transcranial brain stimulation, have been the most popular method for the last decade to monitor the functional integrity of the motor system during surgery. It was originally difficult to record reliable and reproducible potentials under general anesthesia, especially when inhalation-based anesthetic agents that suppressed the firing of anterior horn neurons were used. Advances in anesthesia, including the introduction of intravenous anesthetic agents, and progress in stimulation techniques, including the use of pulse trains, improved the reliability and reproducibility of TcMEP responses. However, TcMEPs are much smaller in amplitude compared with compound muscle action potentials evoked by maximal peripheral nerve stimulation, and vary from one trial to another in clinical practice, suggesting that only a limited number of spinal motor neurons innervating the target muscle are excited in anesthetized patients. Therefore, reliable interpretation of the critical changes in TcMEPs remains difficult and controversial. Additionally, false negative cases have been occasionally encountered. Recently, several facilitative techniques using central or peripheral stimuli, preceding transcranial electrical stimulation, have been employed to achieve sufficient depolarization of motor neurons and augment TcMEP responses. These techniques might have potentials to improve the reliability of intraoperative motor pathway monitoring using TcMEPs.
format Online
Article
Text
id pubmed-4987444
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-49874442016-08-17 Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring TSUTSUI, Shunji YAMADA, Hiroshi Neurol Med Chir (Tokyo) Review Article Transcranial motor evoked potentials (TcMEPs), which are muscle action potentials elicited by transcranial brain stimulation, have been the most popular method for the last decade to monitor the functional integrity of the motor system during surgery. It was originally difficult to record reliable and reproducible potentials under general anesthesia, especially when inhalation-based anesthetic agents that suppressed the firing of anterior horn neurons were used. Advances in anesthesia, including the introduction of intravenous anesthetic agents, and progress in stimulation techniques, including the use of pulse trains, improved the reliability and reproducibility of TcMEP responses. However, TcMEPs are much smaller in amplitude compared with compound muscle action potentials evoked by maximal peripheral nerve stimulation, and vary from one trial to another in clinical practice, suggesting that only a limited number of spinal motor neurons innervating the target muscle are excited in anesthetized patients. Therefore, reliable interpretation of the critical changes in TcMEPs remains difficult and controversial. Additionally, false negative cases have been occasionally encountered. Recently, several facilitative techniques using central or peripheral stimuli, preceding transcranial electrical stimulation, have been employed to achieve sufficient depolarization of motor neurons and augment TcMEP responses. These techniques might have potentials to improve the reliability of intraoperative motor pathway monitoring using TcMEPs. The Japan Neurosurgical Society 2016-08 2016-03-02 /pmc/articles/PMC4987444/ /pubmed/26935781 http://dx.doi.org/10.2176/nmc.ra.2015-0307 Text en © 2016 The Japan Neurosurgical Society This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Review Article
TSUTSUI, Shunji
YAMADA, Hiroshi
Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title_full Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title_fullStr Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title_full_unstemmed Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title_short Basic Principles and Recent Trends of Transcranial Motor Evoked Potentials in Intraoperative Neurophysiologic Monitoring
title_sort basic principles and recent trends of transcranial motor evoked potentials in intraoperative neurophysiologic monitoring
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4987444/
https://www.ncbi.nlm.nih.gov/pubmed/26935781
http://dx.doi.org/10.2176/nmc.ra.2015-0307
work_keys_str_mv AT tsutsuishunji basicprinciplesandrecenttrendsoftranscranialmotorevokedpotentialsinintraoperativeneurophysiologicmonitoring
AT yamadahiroshi basicprinciplesandrecenttrendsoftranscranialmotorevokedpotentialsinintraoperativeneurophysiologicmonitoring