Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study

BACKGROUND AND AIMS: Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O(2):N(2)O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult p...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Mona, Sinha, Renu, Trikha, Anjan, Ramachandran, Rashmi, Chandralekha, C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4989807/
https://www.ncbi.nlm.nih.gov/pubmed/27601739
http://dx.doi.org/10.4103/0019-5049.187787
_version_ 1782448607292555264
author Sharma, Mona
Sinha, Renu
Trikha, Anjan
Ramachandran, Rashmi
Chandralekha, C
author_facet Sharma, Mona
Sinha, Renu
Trikha, Anjan
Ramachandran, Rashmi
Chandralekha, C
author_sort Sharma, Mona
collection PubMed
description BACKGROUND AND AIMS: Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O(2):N(2)O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult patients for various parameters. METHODS: A total of 120 patients were randomly allocated to four groups, according to composition of gases used to inflate the PLMA cuff to achieve 40 cmH(2) O cuff pressure, air (Group A), 50% O(2) :air (Group OA), 50% O(2):N(2)O (Group ON) and 100% O(2) (Group O). Cuff pressure, cuff volume and ventilator parameters were monitored intraoperatively. Pharyngolaryngeal parameters were assessed at 1, 2 and 24 h postoperatively. Statistical analysis was performed using ANOVA, Fisher's exact test and step-wise logistic regression. RESULTS: Cuff pressure significantly increased at 10, 15 and 30 min in Group A, OA and O from initial pressure. Cuff pressure decreased at 5 min in Group ON (36.6 ± 3.5 cmH(2) O) (P = 0.42). PLMA cuff volume increased in Group A, OA, O, but decreased in Group ON (6.16 ± 2.8 ml [P < 0.001], 4.7 ± 3.8 ml [P < 0.001], 1.4 ± 3.19 ml [P = 0.023] and − 1.7 ± 4.9 ml [P = 0.064], respectively), from basal levels. Ventilatory parameters were comparable in all four groups. There was no significant association between sore throat and cuff pressure, with odds ratio 1.002. CONCLUSION: Cuff inflation with 50% O(2):N(2)O mixture provided more stable cuff pressure in comparison to air, O(2) :air, 100% O(2) during O(2):N(2)O anaesthesia. Ventilatory parameters did not change with variation in PLMA cuff pressure. Post-operative sore throat had no correlation with cuff pressure.
format Online
Article
Text
id pubmed-4989807
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-49898072016-09-06 Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study Sharma, Mona Sinha, Renu Trikha, Anjan Ramachandran, Rashmi Chandralekha, C Indian J Anaesth Original Article BACKGROUND AND AIMS: Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O(2):N(2)O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult patients for various parameters. METHODS: A total of 120 patients were randomly allocated to four groups, according to composition of gases used to inflate the PLMA cuff to achieve 40 cmH(2) O cuff pressure, air (Group A), 50% O(2) :air (Group OA), 50% O(2):N(2)O (Group ON) and 100% O(2) (Group O). Cuff pressure, cuff volume and ventilator parameters were monitored intraoperatively. Pharyngolaryngeal parameters were assessed at 1, 2 and 24 h postoperatively. Statistical analysis was performed using ANOVA, Fisher's exact test and step-wise logistic regression. RESULTS: Cuff pressure significantly increased at 10, 15 and 30 min in Group A, OA and O from initial pressure. Cuff pressure decreased at 5 min in Group ON (36.6 ± 3.5 cmH(2) O) (P = 0.42). PLMA cuff volume increased in Group A, OA, O, but decreased in Group ON (6.16 ± 2.8 ml [P < 0.001], 4.7 ± 3.8 ml [P < 0.001], 1.4 ± 3.19 ml [P = 0.023] and − 1.7 ± 4.9 ml [P = 0.064], respectively), from basal levels. Ventilatory parameters were comparable in all four groups. There was no significant association between sore throat and cuff pressure, with odds ratio 1.002. CONCLUSION: Cuff inflation with 50% O(2):N(2)O mixture provided more stable cuff pressure in comparison to air, O(2) :air, 100% O(2) during O(2):N(2)O anaesthesia. Ventilatory parameters did not change with variation in PLMA cuff pressure. Post-operative sore throat had no correlation with cuff pressure. Medknow Publications & Media Pvt Ltd 2016-08 /pmc/articles/PMC4989807/ /pubmed/27601739 http://dx.doi.org/10.4103/0019-5049.187787 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sharma, Mona
Sinha, Renu
Trikha, Anjan
Ramachandran, Rashmi
Chandralekha, C
Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title_full Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title_fullStr Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title_full_unstemmed Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title_short Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study
title_sort comparison of effects of proseal lma™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: a randomised, double-blind study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4989807/
https://www.ncbi.nlm.nih.gov/pubmed/27601739
http://dx.doi.org/10.4103/0019-5049.187787
work_keys_str_mv AT sharmamona comparisonofeffectsofproseallmalaryngealmaskairwaycuffinflationwithairoxygenairoxygenmixtureandoxygennitrousoxidemixtureinadultsarandomiseddoubleblindstudy
AT sinharenu comparisonofeffectsofproseallmalaryngealmaskairwaycuffinflationwithairoxygenairoxygenmixtureandoxygennitrousoxidemixtureinadultsarandomiseddoubleblindstudy
AT trikhaanjan comparisonofeffectsofproseallmalaryngealmaskairwaycuffinflationwithairoxygenairoxygenmixtureandoxygennitrousoxidemixtureinadultsarandomiseddoubleblindstudy
AT ramachandranrashmi comparisonofeffectsofproseallmalaryngealmaskairwaycuffinflationwithairoxygenairoxygenmixtureandoxygennitrousoxidemixtureinadultsarandomiseddoubleblindstudy
AT chandralekhac comparisonofeffectsofproseallmalaryngealmaskairwaycuffinflationwithairoxygenairoxygenmixtureandoxygennitrousoxidemixtureinadultsarandomiseddoubleblindstudy