Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor

OBJECTIVE: to elaborate and apply a method to assess the efficacy of automated flexible endoscope reprocessors at a time when there is not an official method or trained laboratories to comply with the requirements described in specific standards for this type of health product in Brazil. METHOD: the...

Descripción completa

Detalles Bibliográficos
Autores principales: Graziano, Kazuko Uchikawa, Pereira, Marta Elisa Auler, Koda, Elaine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990042/
https://www.ncbi.nlm.nih.gov/pubmed/27508915
http://dx.doi.org/10.1590/1518-8345.0595.2745
_version_ 1782448632917655552
author Graziano, Kazuko Uchikawa
Pereira, Marta Elisa Auler
Koda, Elaine
author_facet Graziano, Kazuko Uchikawa
Pereira, Marta Elisa Auler
Koda, Elaine
author_sort Graziano, Kazuko Uchikawa
collection PubMed
description OBJECTIVE: to elaborate and apply a method to assess the efficacy of automated flexible endoscope reprocessors at a time when there is not an official method or trained laboratories to comply with the requirements described in specific standards for this type of health product in Brazil. METHOD: the present methodological study was developed based on the following theoretical references: International Organization for Standardization (ISO) standard ISO 15883-4/2008 and Brazilian Health Surveillance Agency (Agência Nacional de Vigilância Sanitária - ANVISA) Collegiate Board Resolution (Resolução de Diretoria Colegiada - RDC) no. 35/2010 and 15/2012. The proposed method was applied to a commercially available device using a high-level 0.2% peracetic acid-based disinfectant. RESULTS: the proposed method of assessment was found to be robust when the recommendations made in the relevant legislation were incorporated with some adjustments to ensure their feasibility. Application of the proposed method provided evidence of the efficacy of the tested equipment for the high-level disinfection of endoscopes. CONCLUSION: the proposed method may serve as a reference for the assessment of flexible endoscope reprocessors, thereby providing solid ground for the purchase of this category of health products.
format Online
Article
Text
id pubmed-4990042
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-49900422016-08-31 Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor Graziano, Kazuko Uchikawa Pereira, Marta Elisa Auler Koda, Elaine Rev Lat Am Enfermagem Original Articles OBJECTIVE: to elaborate and apply a method to assess the efficacy of automated flexible endoscope reprocessors at a time when there is not an official method or trained laboratories to comply with the requirements described in specific standards for this type of health product in Brazil. METHOD: the present methodological study was developed based on the following theoretical references: International Organization for Standardization (ISO) standard ISO 15883-4/2008 and Brazilian Health Surveillance Agency (Agência Nacional de Vigilância Sanitária - ANVISA) Collegiate Board Resolution (Resolução de Diretoria Colegiada - RDC) no. 35/2010 and 15/2012. The proposed method was applied to a commercially available device using a high-level 0.2% peracetic acid-based disinfectant. RESULTS: the proposed method of assessment was found to be robust when the recommendations made in the relevant legislation were incorporated with some adjustments to ensure their feasibility. Application of the proposed method provided evidence of the efficacy of the tested equipment for the high-level disinfection of endoscopes. CONCLUSION: the proposed method may serve as a reference for the assessment of flexible endoscope reprocessors, thereby providing solid ground for the purchase of this category of health products. Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo 2016-08-08 /pmc/articles/PMC4990042/ /pubmed/27508915 http://dx.doi.org/10.1590/1518-8345.0595.2745 Text en http://creativecommons.org/licenses/by/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Articles
Graziano, Kazuko Uchikawa
Pereira, Marta Elisa Auler
Koda, Elaine
Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title_full Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title_fullStr Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title_full_unstemmed Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title_short Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
title_sort methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990042/
https://www.ncbi.nlm.nih.gov/pubmed/27508915
http://dx.doi.org/10.1590/1518-8345.0595.2745
work_keys_str_mv AT grazianokazukouchikawa methodologicalproposalforvalidationofthedisinfectingefficacyofanautomatedflexibleendoscopereprocessor
AT pereiramartaelisaauler methodologicalproposalforvalidationofthedisinfectingefficacyofanautomatedflexibleendoscopereprocessor
AT kodaelaine methodologicalproposalforvalidationofthedisinfectingefficacyofanautomatedflexibleendoscopereprocessor