Cargando…

Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma

PURPOSE: To evaluate intrasession and between-visit reproducibility of sector peripapillary angioflow vessel-density (PAFD, %) values in the optic nerve head (ONH) and radial peripapillary capillaries (RPC) layers, respectively, and to analyze the influence of the corresponding sector retinal nerve...

Descripción completa

Detalles Bibliográficos
Autor principal: Holló, Gábor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990338/
https://www.ncbi.nlm.nih.gov/pubmed/27537500
http://dx.doi.org/10.1371/journal.pone.0161631
_version_ 1782448684078727168
author Holló, Gábor
author_facet Holló, Gábor
author_sort Holló, Gábor
collection PubMed
description PURPOSE: To evaluate intrasession and between-visit reproducibility of sector peripapillary angioflow vessel-density (PAFD, %) values in the optic nerve head (ONH) and radial peripapillary capillaries (RPC) layers, respectively, and to analyze the influence of the corresponding sector retinal nerve fiber layer thickness (RNFLT) on the results. METHODS: High quality images acquired with the Angiovue/RTVue-XR Avanti optical coherence tomograph (Optovue Inc., Fremont, USA) on 1 eye of 18 stable glaucoma and ocular hypertension patients were analyzed using the Optovue 2015.100.0.33 software version. Three images were acquired in one visit and 1 image 3 months later. RESULTS: PAFD image quality for all images necessary to calculate reproducibility was sufficient to analysis only in 18 of the 83 participants (21.7%) who were successfully imaged for RNFLT. Intrasession coefficient of variation (CV) ranged between 2.30 and 3.89%, and 3.51 and 5.12% for the peripapillary sectors in the ONH and RPC layers, respectively. The corresponding between-visit CV values ranged between 3.05 and 4.26%, and 4.99 and 6.90%, respectively. Intrasession SD did not correlate with the corresponding RNFLT in any sector in either layer (P≥0.170). In the ONH layer sector PAFD values did not correlate with the corresponding RNFLT values (P≥0.100). In contrast, in the RPC layer a significant positive correlation between the corresponding sector PAFD and RNFLT values was found for all but one peripapillary sectors (Pearson-r range: 0.652 to 0.771, P≤0.0046). CONCLUSION: Though in several patients routine use of PAFD measurement may be limited by suboptimal image quality, in the successfully imaged cases (21.7% of the study eyes in the current investigation) reproducibility of sector PAFD values seems to be sufficient for clinical research. In stable patients intrasession variability explains most of the between-visit variability. Sector PAFD variability is independent from sector RNFLT, a marker of glaucoma severity. In the RPC layer sector PAFD and RNFLT show strong to very strong positive correlation.
format Online
Article
Text
id pubmed-4990338
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-49903382016-10-10 Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma Holló, Gábor PLoS One Research Article PURPOSE: To evaluate intrasession and between-visit reproducibility of sector peripapillary angioflow vessel-density (PAFD, %) values in the optic nerve head (ONH) and radial peripapillary capillaries (RPC) layers, respectively, and to analyze the influence of the corresponding sector retinal nerve fiber layer thickness (RNFLT) on the results. METHODS: High quality images acquired with the Angiovue/RTVue-XR Avanti optical coherence tomograph (Optovue Inc., Fremont, USA) on 1 eye of 18 stable glaucoma and ocular hypertension patients were analyzed using the Optovue 2015.100.0.33 software version. Three images were acquired in one visit and 1 image 3 months later. RESULTS: PAFD image quality for all images necessary to calculate reproducibility was sufficient to analysis only in 18 of the 83 participants (21.7%) who were successfully imaged for RNFLT. Intrasession coefficient of variation (CV) ranged between 2.30 and 3.89%, and 3.51 and 5.12% for the peripapillary sectors in the ONH and RPC layers, respectively. The corresponding between-visit CV values ranged between 3.05 and 4.26%, and 4.99 and 6.90%, respectively. Intrasession SD did not correlate with the corresponding RNFLT in any sector in either layer (P≥0.170). In the ONH layer sector PAFD values did not correlate with the corresponding RNFLT values (P≥0.100). In contrast, in the RPC layer a significant positive correlation between the corresponding sector PAFD and RNFLT values was found for all but one peripapillary sectors (Pearson-r range: 0.652 to 0.771, P≤0.0046). CONCLUSION: Though in several patients routine use of PAFD measurement may be limited by suboptimal image quality, in the successfully imaged cases (21.7% of the study eyes in the current investigation) reproducibility of sector PAFD values seems to be sufficient for clinical research. In stable patients intrasession variability explains most of the between-visit variability. Sector PAFD variability is independent from sector RNFLT, a marker of glaucoma severity. In the RPC layer sector PAFD and RNFLT show strong to very strong positive correlation. Public Library of Science 2016-08-18 /pmc/articles/PMC4990338/ /pubmed/27537500 http://dx.doi.org/10.1371/journal.pone.0161631 Text en © 2016 Gábor Holló http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Holló, Gábor
Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title_full Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title_fullStr Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title_full_unstemmed Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title_short Intrasession and Between-Visit Variability of Sector Peripapillary Angioflow Vessel Density Values Measured with the Angiovue Optical Coherence Tomograph in Different Retinal Layers in Ocular Hypertension and Glaucoma
title_sort intrasession and between-visit variability of sector peripapillary angioflow vessel density values measured with the angiovue optical coherence tomograph in different retinal layers in ocular hypertension and glaucoma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990338/
https://www.ncbi.nlm.nih.gov/pubmed/27537500
http://dx.doi.org/10.1371/journal.pone.0161631
work_keys_str_mv AT hollogabor intrasessionandbetweenvisitvariabilityofsectorperipapillaryangioflowvesseldensityvaluesmeasuredwiththeangiovueopticalcoherencetomographindifferentretinallayersinocularhypertensionandglaucoma