A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes

PURPOSE: To assess the accuracy of corneal astigmatism evaluation measured by four techniques, Orbscan IIz(®), Lenstar LS900(®), Cassini(®), and Total Cassini (anterior + posterior surface), in pseudophakic eyes. PATIENTS AND METHODS: A total of 30 patients (46 eyes) who had undergone cataract surge...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferreira, Tiago B, Ribeiro, Filomena J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990375/
https://www.ncbi.nlm.nih.gov/pubmed/27574391
http://dx.doi.org/10.2147/OPTH.S113027
_version_ 1782448691267764224
author Ferreira, Tiago B
Ribeiro, Filomena J
author_facet Ferreira, Tiago B
Ribeiro, Filomena J
author_sort Ferreira, Tiago B
collection PubMed
description PURPOSE: To assess the accuracy of corneal astigmatism evaluation measured by four techniques, Orbscan IIz(®), Lenstar LS900(®), Cassini(®), and Total Cassini (anterior + posterior surface), in pseudophakic eyes. PATIENTS AND METHODS: A total of 30 patients (46 eyes) who had undergone cataract surgery with the implantation of a monofocal intraocular lens (AcrySof IQ) were assessed after surgery. For each eye, subjective assessment of astigmatism and its axis was performed. Minimum, maximum, and mean keratometry and astigmatism and its axis were evaluated using the four measurement techniques. All measurements were compared with the subjective measurements. Agreement between each measurement technique and subjective assessment was evaluated using Bland–Altman plots. Linear regressions were performed and compared. RESULTS: Linear regression analysis of astigmatism axis showed very high R(2) for all models, with Total Cassini showing the least difference to the unit slope (0.052) and the least difference to a null constant (3.790), although not statistically different from the other models. Regarding astigmatism value, the Cassini and Total Cassini models were similar and statistically better than the Lenstar model. Cassini and Total Cassini showed better J0 compared with Orbscan. CONCLUSION: On linear regression models, Cassini and Total Cassini showed the best performance regarding astigmatism value. Cassini and Total Cassini also showed the least J0 deviation from the Cartesian origin compared with Orbscan, which had the lowest performance. Total corneal measurement with the color LED topographer seems to be a better technique for astigmatism assessment.
format Online
Article
Text
id pubmed-4990375
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-49903752016-08-29 A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes Ferreira, Tiago B Ribeiro, Filomena J Clin Ophthalmol Original Research PURPOSE: To assess the accuracy of corneal astigmatism evaluation measured by four techniques, Orbscan IIz(®), Lenstar LS900(®), Cassini(®), and Total Cassini (anterior + posterior surface), in pseudophakic eyes. PATIENTS AND METHODS: A total of 30 patients (46 eyes) who had undergone cataract surgery with the implantation of a monofocal intraocular lens (AcrySof IQ) were assessed after surgery. For each eye, subjective assessment of astigmatism and its axis was performed. Minimum, maximum, and mean keratometry and astigmatism and its axis were evaluated using the four measurement techniques. All measurements were compared with the subjective measurements. Agreement between each measurement technique and subjective assessment was evaluated using Bland–Altman plots. Linear regressions were performed and compared. RESULTS: Linear regression analysis of astigmatism axis showed very high R(2) for all models, with Total Cassini showing the least difference to the unit slope (0.052) and the least difference to a null constant (3.790), although not statistically different from the other models. Regarding astigmatism value, the Cassini and Total Cassini models were similar and statistically better than the Lenstar model. Cassini and Total Cassini showed better J0 compared with Orbscan. CONCLUSION: On linear regression models, Cassini and Total Cassini showed the best performance regarding astigmatism value. Cassini and Total Cassini also showed the least J0 deviation from the Cartesian origin compared with Orbscan, which had the lowest performance. Total corneal measurement with the color LED topographer seems to be a better technique for astigmatism assessment. Dove Medical Press 2016-08-13 /pmc/articles/PMC4990375/ /pubmed/27574391 http://dx.doi.org/10.2147/OPTH.S113027 Text en © 2016 Ferreira and Ribeiro. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Ferreira, Tiago B
Ribeiro, Filomena J
A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title_full A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title_fullStr A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title_full_unstemmed A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title_short A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
title_sort novel color-led corneal topographer to assess astigmatism in pseudophakic eyes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990375/
https://www.ncbi.nlm.nih.gov/pubmed/27574391
http://dx.doi.org/10.2147/OPTH.S113027
work_keys_str_mv AT ferreiratiagob anovelcolorledcornealtopographertoassessastigmatisminpseudophakiceyes
AT ribeirofilomenaj anovelcolorledcornealtopographertoassessastigmatisminpseudophakiceyes
AT ferreiratiagob novelcolorledcornealtopographertoassessastigmatisminpseudophakiceyes
AT ribeirofilomenaj novelcolorledcornealtopographertoassessastigmatisminpseudophakiceyes