Cargando…

Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality

To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwes...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Y., Shepherd, T. A., Li, H., Xin, H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Poultry Science Association, Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990888/
https://www.ncbi.nlm.nih.gov/pubmed/25737567
http://dx.doi.org/10.3382/ps/peu076
_version_ 1782448759946346496
author Zhao, Y.
Shepherd, T. A.
Li, H.
Xin, H.
author_facet Zhao, Y.
Shepherd, T. A.
Li, H.
Xin, H.
author_sort Zhao, Y.
collection PubMed
description To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens’ activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall mean of 11.5) ppm. The 95% confidence interval values (overall mean) of daily mean PM(10) and PM(2.5) concentrations, in mg/m(3), were, respectively, 0.57 to 0.61 (0.59) and 0.033 to 0.037 (0.035) for the conventional cage house, 3.61 to 4.29 (3.95) and 0.374 to 0.446 (0.410) for the aviary house, and 0.42 to 0.46 (0.44) and 0.054 to 0.059 (0.056) for the enriched colony house. Investigation of mitigation practices to improve indoor air quality of the litter-floor aviary housing system is warranted.
format Online
Article
Text
id pubmed-4990888
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Poultry Science Association, Inc.
record_format MEDLINE/PubMed
spelling pubmed-49908882016-09-01 Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality Zhao, Y. Shepherd, T. A. Li, H. Xin, H. Poult Sci Coalition for Sustainable Egg Supply To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens’ activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall mean of 11.5) ppm. The 95% confidence interval values (overall mean) of daily mean PM(10) and PM(2.5) concentrations, in mg/m(3), were, respectively, 0.57 to 0.61 (0.59) and 0.033 to 0.037 (0.035) for the conventional cage house, 3.61 to 4.29 (3.95) and 0.374 to 0.446 (0.410) for the aviary house, and 0.42 to 0.46 (0.44) and 0.054 to 0.059 (0.056) for the enriched colony house. Investigation of mitigation practices to improve indoor air quality of the litter-floor aviary housing system is warranted. Poultry Science Association, Inc. 2015-03-02 2015-03 /pmc/articles/PMC4990888/ /pubmed/25737567 http://dx.doi.org/10.3382/ps/peu076 Text en © The Author 2015. Published by Oxford University Press on behalf of Poultry Science Association. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com.
spellingShingle Coalition for Sustainable Egg Supply
Zhao, Y.
Shepherd, T. A.
Li, H.
Xin, H.
Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title_full Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title_fullStr Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title_full_unstemmed Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title_short Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
title_sort environmental assessment of three egg production systems–part i: monitoring system and indoor air quality
topic Coalition for Sustainable Egg Supply
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990888/
https://www.ncbi.nlm.nih.gov/pubmed/25737567
http://dx.doi.org/10.3382/ps/peu076
work_keys_str_mv AT zhaoy environmentalassessmentofthreeeggproductionsystemspartimonitoringsystemandindoorairquality
AT shepherdta environmentalassessmentofthreeeggproductionsystemspartimonitoringsystemandindoorairquality
AT lih environmentalassessmentofthreeeggproductionsystemspartimonitoringsystemandindoorairquality
AT xinh environmentalassessmentofthreeeggproductionsystemspartimonitoringsystemandindoorairquality