Cargando…

Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study

Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods:...

Descripción completa

Detalles Bibliográficos
Autores principales: Cobelli, Claudio, Schiavon, Michele, Dalla Man, Chiara, Basu, Ananda, Basu, Rita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4991590/
https://www.ncbi.nlm.nih.gov/pubmed/27253751
http://dx.doi.org/10.1089/dia.2016.0112
_version_ 1782448881179557888
author Cobelli, Claudio
Schiavon, Michele
Dalla Man, Chiara
Basu, Ananda
Basu, Rita
author_facet Cobelli, Claudio
Schiavon, Michele
Dalla Man, Chiara
Basu, Ananda
Basu, Rita
author_sort Cobelli, Claudio
collection PubMed
description Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods: To gain insight into this problem, one can use linear systems theory. However, this may lose a more clinical readership, thus we use simulation and two case studies to convey our thinking in an easier way. In particular, we consider BG concentration measured after meal and exercise in 12 healthy volunteers, whereas ISF glucose is simulated using a well-accepted model of blood–ISF glucose kinetics, which permits calculation of the equilibration time, a parameter characterizing the system. Two metrics are defined: blood and ISF glucose difference at each time point and time to reach the same glucose value in blood and ISF. Results: The simulation performed and the two metrics show that the relationship between blood–ISF glucose profiles is more complex than a pure shift in time and that the pattern depends on both equilibration time and BG. Conclusions: In this in silico study, we have illustrated, with simple case studies, the meaning of the of ISF glucose with respect to BG. Understanding that ISF glucose is not just a shifted-in-time version but a distorted mirror of BG is important for a correct use of continuous glucose monitoring for diabetes management.
format Online
Article
Text
id pubmed-4991590
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Mary Ann Liebert, Inc.
record_format MEDLINE/PubMed
spelling pubmed-49915902016-09-06 Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study Cobelli, Claudio Schiavon, Michele Dalla Man, Chiara Basu, Ananda Basu, Rita Diabetes Technol Ther Original Articles Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods: To gain insight into this problem, one can use linear systems theory. However, this may lose a more clinical readership, thus we use simulation and two case studies to convey our thinking in an easier way. In particular, we consider BG concentration measured after meal and exercise in 12 healthy volunteers, whereas ISF glucose is simulated using a well-accepted model of blood–ISF glucose kinetics, which permits calculation of the equilibration time, a parameter characterizing the system. Two metrics are defined: blood and ISF glucose difference at each time point and time to reach the same glucose value in blood and ISF. Results: The simulation performed and the two metrics show that the relationship between blood–ISF glucose profiles is more complex than a pure shift in time and that the pattern depends on both equilibration time and BG. Conclusions: In this in silico study, we have illustrated, with simple case studies, the meaning of the of ISF glucose with respect to BG. Understanding that ISF glucose is not just a shifted-in-time version but a distorted mirror of BG is important for a correct use of continuous glucose monitoring for diabetes management. Mary Ann Liebert, Inc. 2016-08-01 2016-08-01 /pmc/articles/PMC4991590/ /pubmed/27253751 http://dx.doi.org/10.1089/dia.2016.0112 Text en © Claudio Cobelli, et al., 2016; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Articles
Cobelli, Claudio
Schiavon, Michele
Dalla Man, Chiara
Basu, Ananda
Basu, Rita
Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title_full Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title_fullStr Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title_full_unstemmed Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title_short Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
title_sort interstitial fluid glucose is not just a shifted-in-time but a distorted mirror of blood glucose: insight from an in silico study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4991590/
https://www.ncbi.nlm.nih.gov/pubmed/27253751
http://dx.doi.org/10.1089/dia.2016.0112
work_keys_str_mv AT cobelliclaudio interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy
AT schiavonmichele interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy
AT dallamanchiara interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy
AT basuananda interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy
AT basurita interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy