Cargando…
Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study
Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4991590/ https://www.ncbi.nlm.nih.gov/pubmed/27253751 http://dx.doi.org/10.1089/dia.2016.0112 |
_version_ | 1782448881179557888 |
---|---|
author | Cobelli, Claudio Schiavon, Michele Dalla Man, Chiara Basu, Ananda Basu, Rita |
author_facet | Cobelli, Claudio Schiavon, Michele Dalla Man, Chiara Basu, Ananda Basu, Rita |
author_sort | Cobelli, Claudio |
collection | PubMed |
description | Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods: To gain insight into this problem, one can use linear systems theory. However, this may lose a more clinical readership, thus we use simulation and two case studies to convey our thinking in an easier way. In particular, we consider BG concentration measured after meal and exercise in 12 healthy volunteers, whereas ISF glucose is simulated using a well-accepted model of blood–ISF glucose kinetics, which permits calculation of the equilibration time, a parameter characterizing the system. Two metrics are defined: blood and ISF glucose difference at each time point and time to reach the same glucose value in blood and ISF. Results: The simulation performed and the two metrics show that the relationship between blood–ISF glucose profiles is more complex than a pure shift in time and that the pattern depends on both equilibration time and BG. Conclusions: In this in silico study, we have illustrated, with simple case studies, the meaning of the of ISF glucose with respect to BG. Understanding that ISF glucose is not just a shifted-in-time version but a distorted mirror of BG is important for a correct use of continuous glucose monitoring for diabetes management. |
format | Online Article Text |
id | pubmed-4991590 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Mary Ann Liebert, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-49915902016-09-06 Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study Cobelli, Claudio Schiavon, Michele Dalla Man, Chiara Basu, Ananda Basu, Rita Diabetes Technol Ther Original Articles Background: Glucose sensors measure glucose concentration in the interstitial fluid (ISF), remote from blood. ISF glucose is well known to be “delayed” with respect to blood glucose (BG). However, ISF glucose is not simply a shifted-in-time version of BG but exhibits a more complex pattern. Methods: To gain insight into this problem, one can use linear systems theory. However, this may lose a more clinical readership, thus we use simulation and two case studies to convey our thinking in an easier way. In particular, we consider BG concentration measured after meal and exercise in 12 healthy volunteers, whereas ISF glucose is simulated using a well-accepted model of blood–ISF glucose kinetics, which permits calculation of the equilibration time, a parameter characterizing the system. Two metrics are defined: blood and ISF glucose difference at each time point and time to reach the same glucose value in blood and ISF. Results: The simulation performed and the two metrics show that the relationship between blood–ISF glucose profiles is more complex than a pure shift in time and that the pattern depends on both equilibration time and BG. Conclusions: In this in silico study, we have illustrated, with simple case studies, the meaning of the of ISF glucose with respect to BG. Understanding that ISF glucose is not just a shifted-in-time version but a distorted mirror of BG is important for a correct use of continuous glucose monitoring for diabetes management. Mary Ann Liebert, Inc. 2016-08-01 2016-08-01 /pmc/articles/PMC4991590/ /pubmed/27253751 http://dx.doi.org/10.1089/dia.2016.0112 Text en © Claudio Cobelli, et al., 2016; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Articles Cobelli, Claudio Schiavon, Michele Dalla Man, Chiara Basu, Ananda Basu, Rita Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title | Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title_full | Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title_fullStr | Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title_full_unstemmed | Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title_short | Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study |
title_sort | interstitial fluid glucose is not just a shifted-in-time but a distorted mirror of blood glucose: insight from an in silico study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4991590/ https://www.ncbi.nlm.nih.gov/pubmed/27253751 http://dx.doi.org/10.1089/dia.2016.0112 |
work_keys_str_mv | AT cobelliclaudio interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy AT schiavonmichele interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy AT dallamanchiara interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy AT basuananda interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy AT basurita interstitialfluidglucoseisnotjustashiftedintimebutadistortedmirrorofbloodglucoseinsightfromaninsilicostudy |