Cargando…
Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography
BACKGROUND: Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ven...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4994319/ https://www.ncbi.nlm.nih.gov/pubmed/27550185 http://dx.doi.org/10.1186/s12947-016-0078-z |
_version_ | 1782449305539313664 |
---|---|
author | Shen, Jiaqi Zhou, Qiao Liu, Yue Luo, Runlan Tan, Bijun Li, Guangsen |
author_facet | Shen, Jiaqi Zhou, Qiao Liu, Yue Luo, Runlan Tan, Bijun Li, Guangsen |
author_sort | Shen, Jiaqi |
collection | PubMed |
description | BACKGROUND: Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ventricular (LV) function. The aim of our study is to evaluate the LA function in patients with IDA by 2D-STE. METHODS: 65 patients with IDA were selected. This group of patients was then divided into two groups according to the degree of hemoglobin: group B (Hb > 90 g/L) and group C (Hb60 ~ 90 g/L). Another 30 healthy people were also selected as control group A. Conventional echocardiography parameters, such as left atrial diameter (LAD), peak E and A of mitralis (E, A), E/A, end-diastolic thickness of ventricular septum (IVST d), end-diastolic thickness of LV posterior wall (PWTd) and left ventricular end-diastolic dimension (LVDd) were obtained from these three groups. Left atrial minimum volume (LAVmin), left atrial pre-atrial contraction volume (LAVp) and left atrial maximum volume (LAVmax) were measured by Simpson’s rule, whereas left atrial active ejection fraction (LAAEF) and left atrial passive ejection fraction (LAPEF) were obtained from calculation. Two-dimensional images were acquired from apical four-chamber view and two-chamber view to store images for offline analysis. The global peak atrial longitudinal strain and strain rate of systolic LV (GLSs, GLSRs) as well as early and late diastolic LV strain rate (GLSRe, GLSRa) curves of LA were acquired in each LA segment from basal segment to top segment of LA by 2D-STE. RESULTS: Compared with group A, there were no differences between group B and group A (all P > 0.05). The LAAEF and GLSRa were significantly higher in group C compared with those of group A and group B (all P < 0.01). The LAPEF, GLSs, GLSRs and GLSRe were significantly lower in group C compared with those of group A and group B (all P < 0.01). CONCLUSIONS: 2D-STE could evaluate the LA function in patients with IDA. |
format | Online Article Text |
id | pubmed-4994319 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-49943192016-08-24 Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography Shen, Jiaqi Zhou, Qiao Liu, Yue Luo, Runlan Tan, Bijun Li, Guangsen Cardiovasc Ultrasound Research BACKGROUND: Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ventricular (LV) function. The aim of our study is to evaluate the LA function in patients with IDA by 2D-STE. METHODS: 65 patients with IDA were selected. This group of patients was then divided into two groups according to the degree of hemoglobin: group B (Hb > 90 g/L) and group C (Hb60 ~ 90 g/L). Another 30 healthy people were also selected as control group A. Conventional echocardiography parameters, such as left atrial diameter (LAD), peak E and A of mitralis (E, A), E/A, end-diastolic thickness of ventricular septum (IVST d), end-diastolic thickness of LV posterior wall (PWTd) and left ventricular end-diastolic dimension (LVDd) were obtained from these three groups. Left atrial minimum volume (LAVmin), left atrial pre-atrial contraction volume (LAVp) and left atrial maximum volume (LAVmax) were measured by Simpson’s rule, whereas left atrial active ejection fraction (LAAEF) and left atrial passive ejection fraction (LAPEF) were obtained from calculation. Two-dimensional images were acquired from apical four-chamber view and two-chamber view to store images for offline analysis. The global peak atrial longitudinal strain and strain rate of systolic LV (GLSs, GLSRs) as well as early and late diastolic LV strain rate (GLSRe, GLSRa) curves of LA were acquired in each LA segment from basal segment to top segment of LA by 2D-STE. RESULTS: Compared with group A, there were no differences between group B and group A (all P > 0.05). The LAAEF and GLSRa were significantly higher in group C compared with those of group A and group B (all P < 0.01). The LAPEF, GLSs, GLSRs and GLSRe were significantly lower in group C compared with those of group A and group B (all P < 0.01). CONCLUSIONS: 2D-STE could evaluate the LA function in patients with IDA. BioMed Central 2016-08-23 /pmc/articles/PMC4994319/ /pubmed/27550185 http://dx.doi.org/10.1186/s12947-016-0078-z Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Shen, Jiaqi Zhou, Qiao Liu, Yue Luo, Runlan Tan, Bijun Li, Guangsen Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title | Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title_full | Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title_fullStr | Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title_full_unstemmed | Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title_short | Evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
title_sort | evaluation of left atrial function in patients with iron-deficiency anemia by two-dimensional speckle tracking echocardiography |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4994319/ https://www.ncbi.nlm.nih.gov/pubmed/27550185 http://dx.doi.org/10.1186/s12947-016-0078-z |
work_keys_str_mv | AT shenjiaqi evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography AT zhouqiao evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography AT liuyue evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography AT luorunlan evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography AT tanbijun evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography AT liguangsen evaluationofleftatrialfunctioninpatientswithirondeficiencyanemiabytwodimensionalspeckletrackingechocardiography |