Cargando…

Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study

OBJECTIVE: To optimize enhancement of pulmonary arteries and facilitate diagnosis of pulmonary embolism (PE), modern computed tomography angiography (CTA) contains a contrast bolus tracking system. We explored the diagnostic accuracy of the time-intensity curves given by this automated system to ide...

Descripción completa

Detalles Bibliográficos
Autores principales: John, Gregor, Platon, Alexandra, Poletti, Pierre-Alexandre, Perrier, Arnaud, Bendjelid, Karim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4994948/
https://www.ncbi.nlm.nih.gov/pubmed/27551831
http://dx.doi.org/10.1371/journal.pone.0159674
_version_ 1782449391659909120
author John, Gregor
Platon, Alexandra
Poletti, Pierre-Alexandre
Perrier, Arnaud
Bendjelid, Karim
author_facet John, Gregor
Platon, Alexandra
Poletti, Pierre-Alexandre
Perrier, Arnaud
Bendjelid, Karim
author_sort John, Gregor
collection PubMed
description OBJECTIVE: To optimize enhancement of pulmonary arteries and facilitate diagnosis of pulmonary embolism (PE), modern computed tomography angiography (CTA) contains a contrast bolus tracking system. We explored the diagnostic accuracy of the time-intensity curves given by this automated system to identify right ventricular dysfunction (RVD) in acute PE. METHODS: 114 CTAs with a diagnosis of PE were reviewed. RVD was defined as right-to-left ventricular diameter ratio of 1 or greater. Four parameters on time-intensity curves were identified. Parameters between CTAs with and those without RVD were compared with the Wilcoxon rank-sum test. The ability of the four parameters to discriminate patients with RVD was explored by compiling the area under the operating curves (AUC). RESULTS: The time needed by the contrast media to reach the pulmonary artery [8 seconds (IQR: 7–9) versus 7 seconds (IQR: 6–8), p<0.01], the time needed to reach 40 Hounsfield units (HU) [11 seconds (IQR: 8.5–14) versus 9.5 seconds (IQR: 8–10.5), p<0.01], and the contrast intensity reached after 10 seconds [19 HU (IQR: 4–67) versus 53 HU (IQR: 32–80), p<0.05] were all statistically different between CTA with and CTA without RVD. Those three parameters changed gradually across severity categories of RVD (p<0.05 for trend). Their AUC to identify RVD ranged from 0.63 to 0.66. The slope of contrast intensity over time was not informative: [31 HU/s (IQR: 20–57) in CTA with, compared to 36 HU/s (IQR: 22.5–53) in CTA without RVD, p = 0.60]. CONCLUSION: Several parameters of the time-intensity curve obtained by the bolus tracking system are associated with RVD assessed on CTA images. Of those, the time needed to reach a predefined threshold seems to be the easiest to obtain in any CTA without additional processing time or contrast injection. However, the performance of those parameters is globally low.
format Online
Article
Text
id pubmed-4994948
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-49949482016-09-12 Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study John, Gregor Platon, Alexandra Poletti, Pierre-Alexandre Perrier, Arnaud Bendjelid, Karim PLoS One Research Article OBJECTIVE: To optimize enhancement of pulmonary arteries and facilitate diagnosis of pulmonary embolism (PE), modern computed tomography angiography (CTA) contains a contrast bolus tracking system. We explored the diagnostic accuracy of the time-intensity curves given by this automated system to identify right ventricular dysfunction (RVD) in acute PE. METHODS: 114 CTAs with a diagnosis of PE were reviewed. RVD was defined as right-to-left ventricular diameter ratio of 1 or greater. Four parameters on time-intensity curves were identified. Parameters between CTAs with and those without RVD were compared with the Wilcoxon rank-sum test. The ability of the four parameters to discriminate patients with RVD was explored by compiling the area under the operating curves (AUC). RESULTS: The time needed by the contrast media to reach the pulmonary artery [8 seconds (IQR: 7–9) versus 7 seconds (IQR: 6–8), p<0.01], the time needed to reach 40 Hounsfield units (HU) [11 seconds (IQR: 8.5–14) versus 9.5 seconds (IQR: 8–10.5), p<0.01], and the contrast intensity reached after 10 seconds [19 HU (IQR: 4–67) versus 53 HU (IQR: 32–80), p<0.05] were all statistically different between CTA with and CTA without RVD. Those three parameters changed gradually across severity categories of RVD (p<0.05 for trend). Their AUC to identify RVD ranged from 0.63 to 0.66. The slope of contrast intensity over time was not informative: [31 HU/s (IQR: 20–57) in CTA with, compared to 36 HU/s (IQR: 22.5–53) in CTA without RVD, p = 0.60]. CONCLUSION: Several parameters of the time-intensity curve obtained by the bolus tracking system are associated with RVD assessed on CTA images. Of those, the time needed to reach a predefined threshold seems to be the easiest to obtain in any CTA without additional processing time or contrast injection. However, the performance of those parameters is globally low. Public Library of Science 2016-08-23 /pmc/articles/PMC4994948/ /pubmed/27551831 http://dx.doi.org/10.1371/journal.pone.0159674 Text en © 2016 John et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
John, Gregor
Platon, Alexandra
Poletti, Pierre-Alexandre
Perrier, Arnaud
Bendjelid, Karim
Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title_full Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title_fullStr Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title_full_unstemmed Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title_short Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
title_sort contrast circulation time to assess right ventricular dysfunction in pulmonary embolism: a retrospective pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4994948/
https://www.ncbi.nlm.nih.gov/pubmed/27551831
http://dx.doi.org/10.1371/journal.pone.0159674
work_keys_str_mv AT johngregor contrastcirculationtimetoassessrightventriculardysfunctioninpulmonaryembolismaretrospectivepilotstudy
AT platonalexandra contrastcirculationtimetoassessrightventriculardysfunctioninpulmonaryembolismaretrospectivepilotstudy
AT polettipierrealexandre contrastcirculationtimetoassessrightventriculardysfunctioninpulmonaryembolismaretrospectivepilotstudy
AT perrierarnaud contrastcirculationtimetoassessrightventriculardysfunctioninpulmonaryembolismaretrospectivepilotstudy
AT bendjelidkarim contrastcirculationtimetoassessrightventriculardysfunctioninpulmonaryembolismaretrospectivepilotstudy