Cargando…

Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography

PURPOSE: To investigate the appearance of choriocapillaris (CC) flow under drusen by comparing long-wavelength (1050 nm) swept-source optical coherence tomography (SS-OCT) angiography with shorter-wavelength (840 nm) spectral-domain (SD) OCT angiography. METHODS: Patients with drusen imaged on both...

Descripción completa

Detalles Bibliográficos
Autores principales: Lane, Mark, Moult, Eric M., Novais, Eduardo A., Louzada, Ricardo N., Cole, Emily D., Lee, ByungKun, Husvogt, Lennart, Keane, Pearse A., Denniston, Alastair K., Witkin, André J., Baumal, Caroline R., Fujimoto, James G., Duker, Jay S., Waheed, Nadia K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995042/
https://www.ncbi.nlm.nih.gov/pubmed/27547891
http://dx.doi.org/10.1167/iovs.15-18915
_version_ 1782449409756233728
author Lane, Mark
Moult, Eric M.
Novais, Eduardo A.
Louzada, Ricardo N.
Cole, Emily D.
Lee, ByungKun
Husvogt, Lennart
Keane, Pearse A.
Denniston, Alastair K.
Witkin, André J.
Baumal, Caroline R.
Fujimoto, James G.
Duker, Jay S.
Waheed, Nadia K.
author_facet Lane, Mark
Moult, Eric M.
Novais, Eduardo A.
Louzada, Ricardo N.
Cole, Emily D.
Lee, ByungKun
Husvogt, Lennart
Keane, Pearse A.
Denniston, Alastair K.
Witkin, André J.
Baumal, Caroline R.
Fujimoto, James G.
Duker, Jay S.
Waheed, Nadia K.
author_sort Lane, Mark
collection PubMed
description PURPOSE: To investigate the appearance of choriocapillaris (CC) flow under drusen by comparing long-wavelength (1050 nm) swept-source optical coherence tomography (SS-OCT) angiography with shorter-wavelength (840 nm) spectral-domain (SD) OCT angiography. METHODS: Patients with drusen imaged on both devices on the same day were selected and graded. Ambiguous OCT angiography (OCTA) signal loss was defined as low OCTA signal on the en face OCTA CC image that also had low OCT signal in the corresponding area on the en face OCT CC image and OCT B-scans. Unambiguous OCTA signal loss was defined as low OCTA signal on the en face OCTA CC image that did not have low OCT signal in the corresponding area on the en face OCT CC image and OCT B-scans. False-positive flow impairment on SS-OCTA was defined as ambiguous OCTA signal loss on SS-OCTA but no OCTA signal loss on SD-OCTA. False-positive flow impairment on SD-OCTA was defined as ambiguous OCTA signal loss on SD-OCTA but no OCTA signal loss on SS-OCTA. RESULTS: Nine eyes from seven patients were enrolled, 23 drusen were analyzed. On 840-nm SD-OCTA, 17 drusen (73.9%) exhibited OCTA signal loss. Fourteen (82.4%) were classified as ambiguous, and three (17.6%) were classified as unambiguous; 10 (58.8%) were classified as having false-positive flow impairment. On 1050-nm SS-OCTA, seven drusen (30.4%) exhibited OCTA signal loss and were classified as unambiguous; none were classified as having false-positive flow impairment. CONCLUSIONS: Results showed that 1050-nm SS-OCTA appears less prone to producing areas of false-positive flow impairment under drusen.
format Online
Article
Text
id pubmed-4995042
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-49950422017-02-01 Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography Lane, Mark Moult, Eric M. Novais, Eduardo A. Louzada, Ricardo N. Cole, Emily D. Lee, ByungKun Husvogt, Lennart Keane, Pearse A. Denniston, Alastair K. Witkin, André J. Baumal, Caroline R. Fujimoto, James G. Duker, Jay S. Waheed, Nadia K. Invest Ophthalmol Vis Sci Article PURPOSE: To investigate the appearance of choriocapillaris (CC) flow under drusen by comparing long-wavelength (1050 nm) swept-source optical coherence tomography (SS-OCT) angiography with shorter-wavelength (840 nm) spectral-domain (SD) OCT angiography. METHODS: Patients with drusen imaged on both devices on the same day were selected and graded. Ambiguous OCT angiography (OCTA) signal loss was defined as low OCTA signal on the en face OCTA CC image that also had low OCT signal in the corresponding area on the en face OCT CC image and OCT B-scans. Unambiguous OCTA signal loss was defined as low OCTA signal on the en face OCTA CC image that did not have low OCT signal in the corresponding area on the en face OCT CC image and OCT B-scans. False-positive flow impairment on SS-OCTA was defined as ambiguous OCTA signal loss on SS-OCTA but no OCTA signal loss on SD-OCTA. False-positive flow impairment on SD-OCTA was defined as ambiguous OCTA signal loss on SD-OCTA but no OCTA signal loss on SS-OCTA. RESULTS: Nine eyes from seven patients were enrolled, 23 drusen were analyzed. On 840-nm SD-OCTA, 17 drusen (73.9%) exhibited OCTA signal loss. Fourteen (82.4%) were classified as ambiguous, and three (17.6%) were classified as unambiguous; 10 (58.8%) were classified as having false-positive flow impairment. On 1050-nm SS-OCTA, seven drusen (30.4%) exhibited OCTA signal loss and were classified as unambiguous; none were classified as having false-positive flow impairment. CONCLUSIONS: Results showed that 1050-nm SS-OCTA appears less prone to producing areas of false-positive flow impairment under drusen. The Association for Research in Vision and Ophthalmology 2016-08-17 2016-08 /pmc/articles/PMC4995042/ /pubmed/27547891 http://dx.doi.org/10.1167/iovs.15-18915 Text en http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Article
Lane, Mark
Moult, Eric M.
Novais, Eduardo A.
Louzada, Ricardo N.
Cole, Emily D.
Lee, ByungKun
Husvogt, Lennart
Keane, Pearse A.
Denniston, Alastair K.
Witkin, André J.
Baumal, Caroline R.
Fujimoto, James G.
Duker, Jay S.
Waheed, Nadia K.
Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title_full Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title_fullStr Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title_full_unstemmed Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title_short Visualizing the Choriocapillaris Under Drusen: Comparing 1050-nm Swept-Source Versus 840-nm Spectral-Domain Optical Coherence Tomography Angiography
title_sort visualizing the choriocapillaris under drusen: comparing 1050-nm swept-source versus 840-nm spectral-domain optical coherence tomography angiography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995042/
https://www.ncbi.nlm.nih.gov/pubmed/27547891
http://dx.doi.org/10.1167/iovs.15-18915
work_keys_str_mv AT lanemark visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT moultericm visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT novaiseduardoa visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT louzadaricardon visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT coleemilyd visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT leebyungkun visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT husvogtlennart visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT keanepearsea visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT dennistonalastairk visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT witkinandrej visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT baumalcaroliner visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT fujimotojamesg visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT dukerjays visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography
AT waheednadiak visualizingthechoriocapillarisunderdrusencomparing1050nmsweptsourceversus840nmspectraldomainopticalcoherencetomographyangiography