Cargando…
Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws
STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the le...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Spine Surgery
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995254/ https://www.ncbi.nlm.nih.gov/pubmed/27559451 http://dx.doi.org/10.4184/asj.2016.10.4.705 |
_version_ | 1782449441481949184 |
---|---|
author | Tse, Michael Siu Hei Chan, Chi Hin Wong, Kam Kwong Wong, Wing Cheung |
author_facet | Tse, Michael Siu Hei Chan, Chi Hin Wong, Kam Kwong Wong, Wing Cheung |
author_sort | Tse, Michael Siu Hei |
collection | PubMed |
description | STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan. |
format | Online Article Text |
id | pubmed-4995254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Society of Spine Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-49952542016-08-24 Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws Tse, Michael Siu Hei Chan, Chi Hin Wong, Kam Kwong Wong, Wing Cheung Asian Spine J Clinical Study STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan. Korean Society of Spine Surgery 2016-08 2016-08-16 /pmc/articles/PMC4995254/ /pubmed/27559451 http://dx.doi.org/10.4184/asj.2016.10.4.705 Text en Copyright © 2016 by Korean Society of Spine Surgery http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Tse, Michael Siu Hei Chan, Chi Hin Wong, Kam Kwong Wong, Wing Cheung Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title | Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title_full | Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title_fullStr | Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title_full_unstemmed | Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title_short | Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws |
title_sort | quantitative anatomy of c7 vertebra in southern chinese for insertion of lateral mass screws and pedicle screws |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995254/ https://www.ncbi.nlm.nih.gov/pubmed/27559451 http://dx.doi.org/10.4184/asj.2016.10.4.705 |
work_keys_str_mv | AT tsemichaelsiuhei quantitativeanatomyofc7vertebrainsouthernchineseforinsertionoflateralmassscrewsandpediclescrews AT chanchihin quantitativeanatomyofc7vertebrainsouthernchineseforinsertionoflateralmassscrewsandpediclescrews AT wongkamkwong quantitativeanatomyofc7vertebrainsouthernchineseforinsertionoflateralmassscrewsandpediclescrews AT wongwingcheung quantitativeanatomyofc7vertebrainsouthernchineseforinsertionoflateralmassscrewsandpediclescrews |