Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy
BACKGROUND: Preeclampsia (PE) is the second most common cause of maternal death after obstetric hemorrhage in Africa, a resource-limited region. This study was designed to examine the potential usefulness of a single screening plasma plasminogen activator inhibitor-1 (PAI-1) and fibronectin (FN) lev...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995812/ https://www.ncbi.nlm.nih.gov/pubmed/27630384 http://dx.doi.org/10.4103/0300-1652.188337 |
_version_ | 1782449547834818560 |
---|---|
author | Ajibola, S. O. Adeyemo, T. A. Afolabi, B. B. Akanmu, A. S. |
author_facet | Ajibola, S. O. Adeyemo, T. A. Afolabi, B. B. Akanmu, A. S. |
author_sort | Ajibola, S. O. |
collection | PubMed |
description | BACKGROUND: Preeclampsia (PE) is the second most common cause of maternal death after obstetric hemorrhage in Africa, a resource-limited region. This study was designed to examine the potential usefulness of a single screening plasma plasminogen activator inhibitor-1 (PAI-1) and fibronectin (FN) level for the prediction of PE in pregnant women. MATERIALS AND METHODS: In a cohort of 180 pregnant women who were normotensive at baseline, venous blood samples were obtained before 20 weeks of gestation for the assay of plasma levels of PAI-1 and FN levels measured by enzyme-linked immunoassay technique. Twenty nonpregnant normotensive women were also evaluated as a control group. Outcomes of gestation were evaluated and correlated with the plasma levels of PAI and FN measured at mid-trimester. Mean plasma values of PAI-1 and FN were also compared between the different outcome groups. RESULTS: Plasma PAI-1 level was significantly higher in the pregnant women (8.68 ± 0.56 ng/ml) than in nonpregnant controls (5.55 ± 0.32 ng/ml) (P = 0.01). However, plasma FN did not show any significant difference in pregnant women (2.60 ± 0.37 μg/ml) and nonpregnant controls (2.60 ± 0.23 μg/ml) (P = 0.9). Mid-trimester mean plasma PAI-1 level measured in women who developed PE (7.08 ± 5.49 ng/ml, n = 12) and gestational hypertension (GH) (9.78 ± 6.2 ng/ml, n = 13) was not significantly different in comparison to normotensive pregnant women (8.78 ± 5.63 ng/ml, n = 153) (P = 0.75). Likewise, the mean FN level in women who developed PE was also not significantly different from nonpreeclamptics; however, the FN level in the pregnant women who developed GH was significantly different from women who remained normotensive throughout pregnancy (P = 0.02). CONCLUSION: Single mid-trimester assessment of PAI-1 and FN levels in maternal plasma was not found to be useful in predicting PE as an outcome of pregnancy in the study population. |
format | Online Article Text |
id | pubmed-4995812 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-49958122016-09-14 Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy Ajibola, S. O. Adeyemo, T. A. Afolabi, B. B. Akanmu, A. S. Niger Med J Original Article BACKGROUND: Preeclampsia (PE) is the second most common cause of maternal death after obstetric hemorrhage in Africa, a resource-limited region. This study was designed to examine the potential usefulness of a single screening plasma plasminogen activator inhibitor-1 (PAI-1) and fibronectin (FN) level for the prediction of PE in pregnant women. MATERIALS AND METHODS: In a cohort of 180 pregnant women who were normotensive at baseline, venous blood samples were obtained before 20 weeks of gestation for the assay of plasma levels of PAI-1 and FN levels measured by enzyme-linked immunoassay technique. Twenty nonpregnant normotensive women were also evaluated as a control group. Outcomes of gestation were evaluated and correlated with the plasma levels of PAI and FN measured at mid-trimester. Mean plasma values of PAI-1 and FN were also compared between the different outcome groups. RESULTS: Plasma PAI-1 level was significantly higher in the pregnant women (8.68 ± 0.56 ng/ml) than in nonpregnant controls (5.55 ± 0.32 ng/ml) (P = 0.01). However, plasma FN did not show any significant difference in pregnant women (2.60 ± 0.37 μg/ml) and nonpregnant controls (2.60 ± 0.23 μg/ml) (P = 0.9). Mid-trimester mean plasma PAI-1 level measured in women who developed PE (7.08 ± 5.49 ng/ml, n = 12) and gestational hypertension (GH) (9.78 ± 6.2 ng/ml, n = 13) was not significantly different in comparison to normotensive pregnant women (8.78 ± 5.63 ng/ml, n = 153) (P = 0.75). Likewise, the mean FN level in women who developed PE was also not significantly different from nonpreeclamptics; however, the FN level in the pregnant women who developed GH was significantly different from women who remained normotensive throughout pregnancy (P = 0.02). CONCLUSION: Single mid-trimester assessment of PAI-1 and FN levels in maternal plasma was not found to be useful in predicting PE as an outcome of pregnancy in the study population. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4995812/ /pubmed/27630384 http://dx.doi.org/10.4103/0300-1652.188337 Text en Copyright: © Nigerian Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Ajibola, S. O. Adeyemo, T. A. Afolabi, B. B. Akanmu, A. S. Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title | Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title_full | Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title_fullStr | Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title_full_unstemmed | Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title_short | Utility of a single mid-trimester measurement of plasminogen activator Type 1 and fibronectin to predict preeclampsia in pregnancy |
title_sort | utility of a single mid-trimester measurement of plasminogen activator type 1 and fibronectin to predict preeclampsia in pregnancy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995812/ https://www.ncbi.nlm.nih.gov/pubmed/27630384 http://dx.doi.org/10.4103/0300-1652.188337 |
work_keys_str_mv | AT ajibolaso utilityofasinglemidtrimestermeasurementofplasminogenactivatortype1andfibronectintopredictpreeclampsiainpregnancy AT adeyemota utilityofasinglemidtrimestermeasurementofplasminogenactivatortype1andfibronectintopredictpreeclampsiainpregnancy AT afolabibb utilityofasinglemidtrimestermeasurementofplasminogenactivatortype1andfibronectintopredictpreeclampsiainpregnancy AT akanmuas utilityofasinglemidtrimestermeasurementofplasminogenactivatortype1andfibronectintopredictpreeclampsiainpregnancy |