Cargando…

Interleaved multivoxel (31)P MR spectroscopy

PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel‐localized dynamic (31)P‐MRS. With multivoxel spectroscopy, (31)P‐MRS time‐series spectra are acquired from multiple independent regions during one exercise‐recovery experiment with the same ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Niess, Fabian, Fiedler, Georg B., Schmid, Albrecht I., Goluch, Sigrun, Kriegl, Roberta, Wolzt, Michael, Moser, Ewald, Meyerspeer, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4996323/
https://www.ncbi.nlm.nih.gov/pubmed/26914656
http://dx.doi.org/10.1002/mrm.26172
_version_ 1782449585464016896
author Niess, Fabian
Fiedler, Georg B.
Schmid, Albrecht I.
Goluch, Sigrun
Kriegl, Roberta
Wolzt, Michael
Moser, Ewald
Meyerspeer, Martin
author_facet Niess, Fabian
Fiedler, Georg B.
Schmid, Albrecht I.
Goluch, Sigrun
Kriegl, Roberta
Wolzt, Michael
Moser, Ewald
Meyerspeer, Martin
author_sort Niess, Fabian
collection PubMed
description PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel‐localized dynamic (31)P‐MRS. With multivoxel spectroscopy, (31)P‐MRS time‐series spectra are acquired from multiple independent regions during one exercise‐recovery experiment with the same time resolution as for singlevoxel measurements. METHODS: Multiple independently selected volumes were localized using temporally interleaved semi‐LASER excitations at 7T. Signal loss caused by mutual saturation from shared excitation or refocusing slices was quantified at partial and full overlap, and potential contamination was investigated in phantom measurements. During an exercise‐recovery experiment both gastrocnemius medialis and soleus of two healthy volunteers were measured using multivoxel acquisitions with a total T (R) of 6 s, while avoiding overlap of excitation slices. RESULTS: Signal reduction by shared adiabatic refocusing slices selected 1 s after the preceding voxel was between 10% (full overlap) and 20% (half overlap), in a phantom measurement. In vivo data were acquired from both muscles within the same exercise experiment, with 13–18% signal reduction. Spectra show phosphocreatine, inorganic phosphate, adenosine‐triposphate, phosphomonoesters, and phosphodiesters. CONCLUSION: Signal decrease was relatively low compared to the 2‐fold increase in information. The approach could help to improve the understanding in metabolic research and is applicable to other organs and nuclei. Magn Reson Med 77:921–927, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
format Online
Article
Text
id pubmed-4996323
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-49963232017-03-01 Interleaved multivoxel (31)P MR spectroscopy Niess, Fabian Fiedler, Georg B. Schmid, Albrecht I. Goluch, Sigrun Kriegl, Roberta Wolzt, Michael Moser, Ewald Meyerspeer, Martin Magn Reson Med Spectroscopic Methodology—Notes PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel‐localized dynamic (31)P‐MRS. With multivoxel spectroscopy, (31)P‐MRS time‐series spectra are acquired from multiple independent regions during one exercise‐recovery experiment with the same time resolution as for singlevoxel measurements. METHODS: Multiple independently selected volumes were localized using temporally interleaved semi‐LASER excitations at 7T. Signal loss caused by mutual saturation from shared excitation or refocusing slices was quantified at partial and full overlap, and potential contamination was investigated in phantom measurements. During an exercise‐recovery experiment both gastrocnemius medialis and soleus of two healthy volunteers were measured using multivoxel acquisitions with a total T (R) of 6 s, while avoiding overlap of excitation slices. RESULTS: Signal reduction by shared adiabatic refocusing slices selected 1 s after the preceding voxel was between 10% (full overlap) and 20% (half overlap), in a phantom measurement. In vivo data were acquired from both muscles within the same exercise experiment, with 13–18% signal reduction. Spectra show phosphocreatine, inorganic phosphate, adenosine‐triposphate, phosphomonoesters, and phosphodiesters. CONCLUSION: Signal decrease was relatively low compared to the 2‐fold increase in information. The approach could help to improve the understanding in metabolic research and is applicable to other organs and nuclei. Magn Reson Med 77:921–927, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2016-02-23 2017-03 /pmc/articles/PMC4996323/ /pubmed/26914656 http://dx.doi.org/10.1002/mrm.26172 Text en © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Spectroscopic Methodology—Notes
Niess, Fabian
Fiedler, Georg B.
Schmid, Albrecht I.
Goluch, Sigrun
Kriegl, Roberta
Wolzt, Michael
Moser, Ewald
Meyerspeer, Martin
Interleaved multivoxel (31)P MR spectroscopy
title Interleaved multivoxel (31)P MR spectroscopy
title_full Interleaved multivoxel (31)P MR spectroscopy
title_fullStr Interleaved multivoxel (31)P MR spectroscopy
title_full_unstemmed Interleaved multivoxel (31)P MR spectroscopy
title_short Interleaved multivoxel (31)P MR spectroscopy
title_sort interleaved multivoxel (31)p mr spectroscopy
topic Spectroscopic Methodology—Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4996323/
https://www.ncbi.nlm.nih.gov/pubmed/26914656
http://dx.doi.org/10.1002/mrm.26172
work_keys_str_mv AT niessfabian interleavedmultivoxel31pmrspectroscopy
AT fiedlergeorgb interleavedmultivoxel31pmrspectroscopy
AT schmidalbrechti interleavedmultivoxel31pmrspectroscopy
AT goluchsigrun interleavedmultivoxel31pmrspectroscopy
AT krieglroberta interleavedmultivoxel31pmrspectroscopy
AT wolztmichael interleavedmultivoxel31pmrspectroscopy
AT moserewald interleavedmultivoxel31pmrspectroscopy
AT meyerspeermartin interleavedmultivoxel31pmrspectroscopy