Cargando…

Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography

Purpose: The purpose of the study was to determine the extent of displacement of the pulmonary vein antrums resulting from the intrinsic motion of the heart using 4D cardiac dual-source computed tomography (DSCT). Methods: Ten consecutive female patients were enrolled in this prospective planning st...

Descripción completa

Detalles Bibliográficos
Autores principales: Bahig, Houda, de Guise, Jacques, Vu, Toni, Chartrand-Lefebvre, Carl, Blais, Danis, Lebeau, Martin, Nguyen, Nhu-Tram, Roberge, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5001956/
https://www.ncbi.nlm.nih.gov/pubmed/27610284
http://dx.doi.org/10.7759/cureus.712
_version_ 1782450494112792576
author Bahig, Houda
de Guise, Jacques
Vu, Toni
Chartrand-Lefebvre, Carl
Blais, Danis
Lebeau, Martin
Nguyen, Nhu-Tram
Roberge, David
author_facet Bahig, Houda
de Guise, Jacques
Vu, Toni
Chartrand-Lefebvre, Carl
Blais, Danis
Lebeau, Martin
Nguyen, Nhu-Tram
Roberge, David
author_sort Bahig, Houda
collection PubMed
description Purpose: The purpose of the study was to determine the extent of displacement of the pulmonary vein antrums resulting from the intrinsic motion of the heart using 4D cardiac dual-source computed tomography (DSCT). Methods: Ten consecutive female patients were enrolled in this prospective planning study. In breath-hold, a contrast-injected cardiac 4-dimensional (4D) computed tomography (CT) synchronized to the electrocardiogram was obtained using a prospective sequential acquisition method including the extreme phases of systole and diastole. Right and left atrial fibrillation target volumes (CTVR and CTVL) were defined, with each target volume containing the antral regions of the superior and inferior pulmonary veins. Four points of interest were used as surrogates for the right superior and inferior pulmonary vein antrum (RSPVA and RIPVA) and the left superior and inferior pulmonary vein antrum (LSPVA and LIPVA). On our 4D post-processing workstation (MIM Maestro™, MIM Software Inc.), maximum displacement of each point of interest from diastole to systole was measured in the mediolateral (ML), anteroposterior (AP), and superoinferior (SI) directions. Results: Median age of the enrolled patients was 60 years (range, 56-71 years). Within the CTVR, the mean displacements of the superior and inferior surrogates were 3 mm vs. 1 mm (p=0.002), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 0 mm (p=0.00001), in the ML, AP, and SI directions, respectively. On the left, mean absolute displacements of the LSPVA vs. LIPVA were similar at 4 mm vs. 1 mm (p=0.0008), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 1 mm (p=0.00001) in the ML, AP, and SI directions. Conclusion: When isolated from breathing, cardiac contraction is associated with minimal inferior pulmonary veins motion and modest (1-6 mm) motion of the superior veins. Target deformation was thus of a magnitude similar or greater than target motion, limiting the potential gains of cardiac tracking. Optimal strategies for cardiac radiosurgery should thus either incorporate the generation of an internal target or cardiac gating. In either case, cardiac 4D DSCT would allow for personalized margin definition.
format Online
Article
Text
id pubmed-5001956
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-50019562016-09-08 Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography Bahig, Houda de Guise, Jacques Vu, Toni Chartrand-Lefebvre, Carl Blais, Danis Lebeau, Martin Nguyen, Nhu-Tram Roberge, David Cureus Radiation Oncology Purpose: The purpose of the study was to determine the extent of displacement of the pulmonary vein antrums resulting from the intrinsic motion of the heart using 4D cardiac dual-source computed tomography (DSCT). Methods: Ten consecutive female patients were enrolled in this prospective planning study. In breath-hold, a contrast-injected cardiac 4-dimensional (4D) computed tomography (CT) synchronized to the electrocardiogram was obtained using a prospective sequential acquisition method including the extreme phases of systole and diastole. Right and left atrial fibrillation target volumes (CTVR and CTVL) were defined, with each target volume containing the antral regions of the superior and inferior pulmonary veins. Four points of interest were used as surrogates for the right superior and inferior pulmonary vein antrum (RSPVA and RIPVA) and the left superior and inferior pulmonary vein antrum (LSPVA and LIPVA). On our 4D post-processing workstation (MIM Maestro™, MIM Software Inc.), maximum displacement of each point of interest from diastole to systole was measured in the mediolateral (ML), anteroposterior (AP), and superoinferior (SI) directions. Results: Median age of the enrolled patients was 60 years (range, 56-71 years). Within the CTVR, the mean displacements of the superior and inferior surrogates were 3 mm vs. 1 mm (p=0.002), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 0 mm (p=0.00001), in the ML, AP, and SI directions, respectively. On the left, mean absolute displacements of the LSPVA vs. LIPVA were similar at 4 mm vs. 1 mm (p=0.0008), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 1 mm (p=0.00001) in the ML, AP, and SI directions. Conclusion: When isolated from breathing, cardiac contraction is associated with minimal inferior pulmonary veins motion and modest (1-6 mm) motion of the superior veins. Target deformation was thus of a magnitude similar or greater than target motion, limiting the potential gains of cardiac tracking. Optimal strategies for cardiac radiosurgery should thus either incorporate the generation of an internal target or cardiac gating. In either case, cardiac 4D DSCT would allow for personalized margin definition. Cureus 2016-07-26 /pmc/articles/PMC5001956/ /pubmed/27610284 http://dx.doi.org/10.7759/cureus.712 Text en Copyright © 2016, Bahig et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Radiation Oncology
Bahig, Houda
de Guise, Jacques
Vu, Toni
Chartrand-Lefebvre, Carl
Blais, Danis
Lebeau, Martin
Nguyen, Nhu-Tram
Roberge, David
Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title_full Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title_fullStr Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title_full_unstemmed Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title_short Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
title_sort analysis of pulmonary vein antrums motion with cardiac contraction using dual-source computed tomography
topic Radiation Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5001956/
https://www.ncbi.nlm.nih.gov/pubmed/27610284
http://dx.doi.org/10.7759/cureus.712
work_keys_str_mv AT bahighouda analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT deguisejacques analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT vutoni analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT chartrandlefebvrecarl analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT blaisdanis analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT lebeaumartin analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT nguyennhutram analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography
AT robergedavid analysisofpulmonaryveinantrumsmotionwithcardiaccontractionusingdualsourcecomputedtomography