Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005562/ https://www.ncbi.nlm.nih.gov/pubmed/27610382 http://dx.doi.org/10.1155/2016/8459018 |
_version_ | 1782450939350745088 |
---|---|
author | Platz, Thomas Gillner, Annett Borgwaldt, Nicole Kroll, Sylvia Roschka, Sybille |
author_facet | Platz, Thomas Gillner, Annett Borgwaldt, Nicole Kroll, Sylvia Roschka, Sybille |
author_sort | Platz, Thomas |
collection | PubMed |
description | Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard. |
format | Online Article Text |
id | pubmed-5005562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-50055622016-09-08 Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction Platz, Thomas Gillner, Annett Borgwaldt, Nicole Kroll, Sylvia Roschka, Sybille Biomed Res Int Clinical Study Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard. Hindawi Publishing Corporation 2016 2016-08-17 /pmc/articles/PMC5005562/ /pubmed/27610382 http://dx.doi.org/10.1155/2016/8459018 Text en Copyright © 2016 Thomas Platz et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Platz, Thomas Gillner, Annett Borgwaldt, Nicole Kroll, Sylvia Roschka, Sybille Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title | Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title_full | Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title_fullStr | Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title_full_unstemmed | Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title_short | Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction |
title_sort | device-training for individuals with thoracic and lumbar spinal cord injury using a powered exoskeleton for technically assisted mobility: achievements and user satisfaction |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005562/ https://www.ncbi.nlm.nih.gov/pubmed/27610382 http://dx.doi.org/10.1155/2016/8459018 |
work_keys_str_mv | AT platzthomas devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction AT gillnerannett devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction AT borgwaldtnicole devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction AT krollsylvia devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction AT roschkasybille devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction |