Cargando…

Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction

Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality o...

Descripción completa

Detalles Bibliográficos
Autores principales: Platz, Thomas, Gillner, Annett, Borgwaldt, Nicole, Kroll, Sylvia, Roschka, Sybille
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005562/
https://www.ncbi.nlm.nih.gov/pubmed/27610382
http://dx.doi.org/10.1155/2016/8459018
_version_ 1782450939350745088
author Platz, Thomas
Gillner, Annett
Borgwaldt, Nicole
Kroll, Sylvia
Roschka, Sybille
author_facet Platz, Thomas
Gillner, Annett
Borgwaldt, Nicole
Kroll, Sylvia
Roschka, Sybille
author_sort Platz, Thomas
collection PubMed
description Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard.
format Online
Article
Text
id pubmed-5005562
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-50055622016-09-08 Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction Platz, Thomas Gillner, Annett Borgwaldt, Nicole Kroll, Sylvia Roschka, Sybille Biomed Res Int Clinical Study Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard. Hindawi Publishing Corporation 2016 2016-08-17 /pmc/articles/PMC5005562/ /pubmed/27610382 http://dx.doi.org/10.1155/2016/8459018 Text en Copyright © 2016 Thomas Platz et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Platz, Thomas
Gillner, Annett
Borgwaldt, Nicole
Kroll, Sylvia
Roschka, Sybille
Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title_full Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title_fullStr Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title_full_unstemmed Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title_short Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction
title_sort device-training for individuals with thoracic and lumbar spinal cord injury using a powered exoskeleton for technically assisted mobility: achievements and user satisfaction
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5005562/
https://www.ncbi.nlm.nih.gov/pubmed/27610382
http://dx.doi.org/10.1155/2016/8459018
work_keys_str_mv AT platzthomas devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction
AT gillnerannett devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction
AT borgwaldtnicole devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction
AT krollsylvia devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction
AT roschkasybille devicetrainingforindividualswiththoracicandlumbarspinalcordinjuryusingapoweredexoskeletonfortechnicallyassistedmobilityachievementsandusersatisfaction