Cargando…

Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study

BACKGROUND: The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer. METHODS: An Elekta Synergy linac with Agili...

Descripción completa

Detalles Bibliográficos
Autores principales: Maier, Johannes, Knott, Bernadette, Maerz, Manuel, Loeschel, Rainer, Koelbl, Oliver, Dobler, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5006633/
https://www.ncbi.nlm.nih.gov/pubmed/27577561
http://dx.doi.org/10.1186/s13014-016-0687-6
_version_ 1782451103372148736
author Maier, Johannes
Knott, Bernadette
Maerz, Manuel
Loeschel, Rainer
Koelbl, Oliver
Dobler, Barbara
author_facet Maier, Johannes
Knott, Bernadette
Maerz, Manuel
Loeschel, Rainer
Koelbl, Oliver
Dobler, Barbara
author_sort Maier, Johannes
collection PubMed
description BACKGROUND: The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer. METHODS: An Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and a tangential arc VMAT (tVMAT), each with and without flattening filter. Plan quality was assessed considering target coverage, sparing of the contralateral breast, the lungs, the heart and the normal tissue. All plans were verified by a 2D-ionisation-chamber-array and delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. RESULTS: Significantly best target coverage and homogeneity was achieved using VMAT FFF with V(95%) = (98.7 ± 0.8) % and HI = (8.2 ± 0.9) % for the SIB and V(95%) = (98.3 ± 0.7) % for the PTV, whereas tVMAT showed significantly lowest doses to the contralateral organs at risk with a D(mean) of (0.7 ± 0.1) Gy for the contralateral lung, (1.0 ± 0.2) Gy for the contralateral breast and (1.4 ± 0.2) Gy for the heart. All plans passed the gamma evaluation with a mean passing rate of (99.2 ± 0.8) %. Delivery times were significantly reduced for VMAT and tVMAT but increased for IMRT, when FFF was used. Lowest delivery times were observed for tVMAT FFF with (1:20 ± 0:07) min. CONCLUSION: Balancing target coverage, OAR sparing and delivery time, VMAT FFF and tVMAT FFF are considered the preferable of the investigated treatment options in simultaneous integrated boost irradiation of right sided breast cancer for the combination of an Elekta Synergy linac with Agility and the treatment planning system Monaco 5.0.
format Online
Article
Text
id pubmed-5006633
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50066332016-09-01 Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study Maier, Johannes Knott, Bernadette Maerz, Manuel Loeschel, Rainer Koelbl, Oliver Dobler, Barbara Radiat Oncol Research BACKGROUND: The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer. METHODS: An Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and a tangential arc VMAT (tVMAT), each with and without flattening filter. Plan quality was assessed considering target coverage, sparing of the contralateral breast, the lungs, the heart and the normal tissue. All plans were verified by a 2D-ionisation-chamber-array and delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. RESULTS: Significantly best target coverage and homogeneity was achieved using VMAT FFF with V(95%) = (98.7 ± 0.8) % and HI = (8.2 ± 0.9) % for the SIB and V(95%) = (98.3 ± 0.7) % for the PTV, whereas tVMAT showed significantly lowest doses to the contralateral organs at risk with a D(mean) of (0.7 ± 0.1) Gy for the contralateral lung, (1.0 ± 0.2) Gy for the contralateral breast and (1.4 ± 0.2) Gy for the heart. All plans passed the gamma evaluation with a mean passing rate of (99.2 ± 0.8) %. Delivery times were significantly reduced for VMAT and tVMAT but increased for IMRT, when FFF was used. Lowest delivery times were observed for tVMAT FFF with (1:20 ± 0:07) min. CONCLUSION: Balancing target coverage, OAR sparing and delivery time, VMAT FFF and tVMAT FFF are considered the preferable of the investigated treatment options in simultaneous integrated boost irradiation of right sided breast cancer for the combination of an Elekta Synergy linac with Agility and the treatment planning system Monaco 5.0. BioMed Central 2016-08-31 /pmc/articles/PMC5006633/ /pubmed/27577561 http://dx.doi.org/10.1186/s13014-016-0687-6 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Maier, Johannes
Knott, Bernadette
Maerz, Manuel
Loeschel, Rainer
Koelbl, Oliver
Dobler, Barbara
Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title_full Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title_fullStr Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title_full_unstemmed Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title_short Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study
title_sort simultaneous integrated boost (sib) radiation therapy of right sided breast cancer with and without flattening filter - a treatment planning study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5006633/
https://www.ncbi.nlm.nih.gov/pubmed/27577561
http://dx.doi.org/10.1186/s13014-016-0687-6
work_keys_str_mv AT maierjohannes simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy
AT knottbernadette simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy
AT maerzmanuel simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy
AT loeschelrainer simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy
AT koelbloliver simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy
AT doblerbarbara simultaneousintegratedboostsibradiationtherapyofrightsidedbreastcancerwithandwithoutflatteningfilteratreatmentplanningstudy