The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma
It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5006993/ https://www.ncbi.nlm.nih.gov/pubmed/27580243 http://dx.doi.org/10.1371/journal.pone.0161742 |
_version_ | 1782451152377348096 |
---|---|
author | Matsuura, Masato Hirasawa, Kazunori Murata, Hiroshi Yanagisawa, Mieko Nakao, Yoshitaka Nakakura, Shunsuke Kiuchi, Yoshiaki Asaoka, Ryo |
author_facet | Matsuura, Masato Hirasawa, Kazunori Murata, Hiroshi Yanagisawa, Mieko Nakao, Yoshitaka Nakakura, Shunsuke Kiuchi, Yoshiaki Asaoka, Ryo |
author_sort | Matsuura, Masato |
collection | PubMed |
description | It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R(2) = 0.67, p <0.001). Similarly, the optimal model for CRF was given by: CRF = -53.5 + 4.2*A1 time + 1.9*A1 length + 20.8*A1 deformation amplitude + 0.8*A2 time + 0.017*CCT (R(2) = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate. |
format | Online Article Text |
id | pubmed-5006993 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-50069932016-09-27 The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma Matsuura, Masato Hirasawa, Kazunori Murata, Hiroshi Yanagisawa, Mieko Nakao, Yoshitaka Nakakura, Shunsuke Kiuchi, Yoshiaki Asaoka, Ryo PLoS One Research Article It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R(2) = 0.67, p <0.001). Similarly, the optimal model for CRF was given by: CRF = -53.5 + 4.2*A1 time + 1.9*A1 length + 20.8*A1 deformation amplitude + 0.8*A2 time + 0.017*CCT (R(2) = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate. Public Library of Science 2016-08-31 /pmc/articles/PMC5006993/ /pubmed/27580243 http://dx.doi.org/10.1371/journal.pone.0161742 Text en © 2016 Matsuura et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Matsuura, Masato Hirasawa, Kazunori Murata, Hiroshi Yanagisawa, Mieko Nakao, Yoshitaka Nakakura, Shunsuke Kiuchi, Yoshiaki Asaoka, Ryo The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title | The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title_full | The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title_fullStr | The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title_full_unstemmed | The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title_short | The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma |
title_sort | relationship between corvis st tonometry and ocular response analyzer measurements in eyes with glaucoma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5006993/ https://www.ncbi.nlm.nih.gov/pubmed/27580243 http://dx.doi.org/10.1371/journal.pone.0161742 |
work_keys_str_mv | AT matsuuramasato therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT hirasawakazunori therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT muratahiroshi therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT yanagisawamieko therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT nakaoyoshitaka therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT nakakurashunsuke therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT kiuchiyoshiaki therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT asaokaryo therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT matsuuramasato relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT hirasawakazunori relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT muratahiroshi relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT yanagisawamieko relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT nakaoyoshitaka relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT nakakurashunsuke relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT kiuchiyoshiaki relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma AT asaokaryo relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma |