Cargando…

Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications

A degradable ultraphosphate (55 mol % P(2)O(5)) quinternary phosphate glass composition has been characterised in terms of its chemical, mechanical and degradation properties both as a bulk material and after drawing into fibres. This glass formulation displayed a large processing window simplifying...

Descripción completa

Detalles Bibliográficos
Autores principales: Colquhoun, Ross, Gadegaard, Nikolaj, Healy, David M., Tanner, K. Elizabeth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007269/
https://www.ncbi.nlm.nih.gov/pubmed/27582069
http://dx.doi.org/10.1007/s10856-016-5752-z
_version_ 1782451176904589312
author Colquhoun, Ross
Gadegaard, Nikolaj
Healy, David M.
Tanner, K. Elizabeth
author_facet Colquhoun, Ross
Gadegaard, Nikolaj
Healy, David M.
Tanner, K. Elizabeth
author_sort Colquhoun, Ross
collection PubMed
description A degradable ultraphosphate (55 mol % P(2)O(5)) quinternary phosphate glass composition has been characterised in terms of its chemical, mechanical and degradation properties both as a bulk material and after drawing into fibres. This glass formulation displayed a large processing window simplifying fibre drawing. The fibres displayed stiffness and strength of 65.5 ± 20.8 GPa and 426±143 MPa. While amorphous discs of the glass displayed a linear dissolution rate of 0.004 mg cm(−2) h(−1) at 37 °C, in a static solution with a reduction in media pH. Once drawn into fibres, the dissolution process dropped the pH to <2 in distilled water, phosphate buffer saline and corrected-simulated body fluid, displaying an autocatalytic effect with >90 % mass loss in 4 days, about seven times faster than anticipated for this solution rate. Only cell culture media was able to buffer the pH taking over a week for full fibre dissolution, however, still four times faster dissolution rate than as a bulk material. However, at early times the development of a HCA layer was seen indicating potential bioactivity. Thus, although initial analysis indicated potential orthopaedic implant applications, autocatalysis leads to accelerating degradation in vitro.
format Online
Article
Text
id pubmed-5007269
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-50072692016-09-16 Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications Colquhoun, Ross Gadegaard, Nikolaj Healy, David M. Tanner, K. Elizabeth J Mater Sci Mater Med Clinical Applications of Biomaterials A degradable ultraphosphate (55 mol % P(2)O(5)) quinternary phosphate glass composition has been characterised in terms of its chemical, mechanical and degradation properties both as a bulk material and after drawing into fibres. This glass formulation displayed a large processing window simplifying fibre drawing. The fibres displayed stiffness and strength of 65.5 ± 20.8 GPa and 426±143 MPa. While amorphous discs of the glass displayed a linear dissolution rate of 0.004 mg cm(−2) h(−1) at 37 °C, in a static solution with a reduction in media pH. Once drawn into fibres, the dissolution process dropped the pH to <2 in distilled water, phosphate buffer saline and corrected-simulated body fluid, displaying an autocatalytic effect with >90 % mass loss in 4 days, about seven times faster than anticipated for this solution rate. Only cell culture media was able to buffer the pH taking over a week for full fibre dissolution, however, still four times faster dissolution rate than as a bulk material. However, at early times the development of a HCA layer was seen indicating potential bioactivity. Thus, although initial analysis indicated potential orthopaedic implant applications, autocatalysis leads to accelerating degradation in vitro. Springer US 2016-08-31 2016 /pmc/articles/PMC5007269/ /pubmed/27582069 http://dx.doi.org/10.1007/s10856-016-5752-z Text en © The Author(s) 2016 This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Clinical Applications of Biomaterials
Colquhoun, Ross
Gadegaard, Nikolaj
Healy, David M.
Tanner, K. Elizabeth
Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title_full Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title_fullStr Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title_full_unstemmed Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title_short Characterisation of CorGlaes(®) Pure 107 fibres for biomedical applications
title_sort characterisation of corglaes(®) pure 107 fibres for biomedical applications
topic Clinical Applications of Biomaterials
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007269/
https://www.ncbi.nlm.nih.gov/pubmed/27582069
http://dx.doi.org/10.1007/s10856-016-5752-z
work_keys_str_mv AT colquhounross characterisationofcorglaespure107fibresforbiomedicalapplications
AT gadegaardnikolaj characterisationofcorglaespure107fibresforbiomedicalapplications
AT healydavidm characterisationofcorglaespure107fibresforbiomedicalapplications
AT tannerkelizabeth characterisationofcorglaespure107fibresforbiomedicalapplications