Cargando…
Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging
OBJECTIVE: To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. MATERIALS AND METHODS...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007390/ https://www.ncbi.nlm.nih.gov/pubmed/27587952 http://dx.doi.org/10.3348/kjr.2016.17.5.641 |
_version_ | 1782451201885863936 |
---|---|
author | Xu, Xiao Quan Choi, Young Jun Sung, Yu Sub Yoon, Ra Gyoung Jang, Seung Won Park, Ji Eun Heo, Young Jin Baek, Jung Hwan Lee, Jeong Hyun |
author_facet | Xu, Xiao Quan Choi, Young Jun Sung, Yu Sub Yoon, Ra Gyoung Jang, Seung Won Park, Ji Eun Heo, Young Jin Baek, Jung Hwan Lee, Jeong Hyun |
author_sort | Xu, Xiao Quan |
collection | PubMed |
description | OBJECTIVE: To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. MATERIALS AND METHODS: We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, T(max), E(max), initial AUC(60), whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. RESULTS: No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). CONCLUSION: Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck. |
format | Online Article Text |
id | pubmed-5007390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-50073902016-09-01 Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging Xu, Xiao Quan Choi, Young Jun Sung, Yu Sub Yoon, Ra Gyoung Jang, Seung Won Park, Ji Eun Heo, Young Jin Baek, Jung Hwan Lee, Jeong Hyun Korean J Radiol Neuroimaging and Head & Neck OBJECTIVE: To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. MATERIALS AND METHODS: We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, T(max), E(max), initial AUC(60), whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. RESULTS: No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). CONCLUSION: Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck. The Korean Society of Radiology 2016 2016-08-23 /pmc/articles/PMC5007390/ /pubmed/27587952 http://dx.doi.org/10.3348/kjr.2016.17.5.641 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Neuroimaging and Head & Neck Xu, Xiao Quan Choi, Young Jun Sung, Yu Sub Yoon, Ra Gyoung Jang, Seung Won Park, Ji Eun Heo, Young Jin Baek, Jung Hwan Lee, Jeong Hyun Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title | Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title_full | Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title_fullStr | Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title_full_unstemmed | Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title_short | Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging |
title_sort | intravoxel incoherent motion mr imaging in the head and neck: correlation with dynamic contrast-enhanced mr imaging and diffusion-weighted imaging |
topic | Neuroimaging and Head & Neck |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007390/ https://www.ncbi.nlm.nih.gov/pubmed/27587952 http://dx.doi.org/10.3348/kjr.2016.17.5.641 |
work_keys_str_mv | AT xuxiaoquan intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT choiyoungjun intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT sungyusub intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT yoonragyoung intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT jangseungwon intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT parkjieun intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT heoyoungjin intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT baekjunghwan intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging AT leejeonghyun intravoxelincoherentmotionmrimagingintheheadandneckcorrelationwithdynamiccontrastenhancedmrimaginganddiffusionweightedimaging |