Cargando…
Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis
BACKGROUND: Not only arterial hypoxemia but acute lung injury also has become the major concerns of one-lung ventilation (OLV). The use of pressure-controlled ventilation (PCV) for OLV offers the potential advantages of lower airway pressure and intrapulmonary shunt, which result in a reduced risk o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007729/ https://www.ncbi.nlm.nih.gov/pubmed/27581657 http://dx.doi.org/10.1186/s12871-016-0238-6 |
_version_ | 1782451262830149632 |
---|---|
author | Kim, Kyu Nam Kim, Dong Won Jeong, Mi Ae Sin, Yeong Hun Lee, Soo Kyung |
author_facet | Kim, Kyu Nam Kim, Dong Won Jeong, Mi Ae Sin, Yeong Hun Lee, Soo Kyung |
author_sort | Kim, Kyu Nam |
collection | PubMed |
description | BACKGROUND: Not only arterial hypoxemia but acute lung injury also has become the major concerns of one-lung ventilation (OLV). The use of pressure-controlled ventilation (PCV) for OLV offers the potential advantages of lower airway pressure and intrapulmonary shunt, which result in a reduced risk of barotrauma and improved oxygenation, respectively. METHODS: We searched Medline, Embase, the Cochrane central register of controlled trials and KoreaMedto find publications comparing the effects of PCV with those of volume-controlled ventilation (VCV) during intraoperative OLV in adults. A meta-analysis of randomized controlled trials was performed using the Cochrane Review Methods. RESULTS: Six studies (259 participants) were included. The PaO(2)/FiO(2) ratio in PCV was higher than in VCV [weighted mean difference (WMD) = 11.04 mmHg, 95 % confidence interval (CI) = 0.30 to 21.77, P = 0.04, I(2) = 3 %] and peak inspiratory pressure was significantly lower in PCV (WMD = −4.91 cm H(2)O, 95 % CI = −7.30 to –2.53, P < 0.0001, I (2) = 91 %). No differences in PaCO(2), tidal volume, heart rate and blood pressure were observed. There were also no differences incompliance, plateau and mean airway pressure. CONCLUSIONS: Our meta-analysis provided the evidence of improved oxygenation in PCV. However, it is difficult to draw any definitive conclusions due to the fact that the duration of ventilation in the studies reviewed was insufficient to reveal clinically relevant benefits or disadvantages of PCV. Significantly lower peak inspiratory pressure is the advantage of PCV. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-016-0238-6) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5007729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-50077292016-09-02 Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis Kim, Kyu Nam Kim, Dong Won Jeong, Mi Ae Sin, Yeong Hun Lee, Soo Kyung BMC Anesthesiol Research Article BACKGROUND: Not only arterial hypoxemia but acute lung injury also has become the major concerns of one-lung ventilation (OLV). The use of pressure-controlled ventilation (PCV) for OLV offers the potential advantages of lower airway pressure and intrapulmonary shunt, which result in a reduced risk of barotrauma and improved oxygenation, respectively. METHODS: We searched Medline, Embase, the Cochrane central register of controlled trials and KoreaMedto find publications comparing the effects of PCV with those of volume-controlled ventilation (VCV) during intraoperative OLV in adults. A meta-analysis of randomized controlled trials was performed using the Cochrane Review Methods. RESULTS: Six studies (259 participants) were included. The PaO(2)/FiO(2) ratio in PCV was higher than in VCV [weighted mean difference (WMD) = 11.04 mmHg, 95 % confidence interval (CI) = 0.30 to 21.77, P = 0.04, I(2) = 3 %] and peak inspiratory pressure was significantly lower in PCV (WMD = −4.91 cm H(2)O, 95 % CI = −7.30 to –2.53, P < 0.0001, I (2) = 91 %). No differences in PaCO(2), tidal volume, heart rate and blood pressure were observed. There were also no differences incompliance, plateau and mean airway pressure. CONCLUSIONS: Our meta-analysis provided the evidence of improved oxygenation in PCV. However, it is difficult to draw any definitive conclusions due to the fact that the duration of ventilation in the studies reviewed was insufficient to reveal clinically relevant benefits or disadvantages of PCV. Significantly lower peak inspiratory pressure is the advantage of PCV. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-016-0238-6) contains supplementary material, which is available to authorized users. BioMed Central 2016-08-31 /pmc/articles/PMC5007729/ /pubmed/27581657 http://dx.doi.org/10.1186/s12871-016-0238-6 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kim, Kyu Nam Kim, Dong Won Jeong, Mi Ae Sin, Yeong Hun Lee, Soo Kyung Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title | Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title_full | Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title_fullStr | Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title_full_unstemmed | Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title_short | Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
title_sort | comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5007729/ https://www.ncbi.nlm.nih.gov/pubmed/27581657 http://dx.doi.org/10.1186/s12871-016-0238-6 |
work_keys_str_mv | AT kimkyunam comparisonofpressurecontrolledventilationwithvolumecontrolledventilationduringonelungventilationasystematicreviewandmetaanalysis AT kimdongwon comparisonofpressurecontrolledventilationwithvolumecontrolledventilationduringonelungventilationasystematicreviewandmetaanalysis AT jeongmiae comparisonofpressurecontrolledventilationwithvolumecontrolledventilationduringonelungventilationasystematicreviewandmetaanalysis AT sinyeonghun comparisonofpressurecontrolledventilationwithvolumecontrolledventilationduringonelungventilationasystematicreviewandmetaanalysis AT leesookyung comparisonofpressurecontrolledventilationwithvolumecontrolledventilationduringonelungventilationasystematicreviewandmetaanalysis |