Cargando…

Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD

This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the or...

Descripción completa

Detalles Bibliográficos
Autores principales: Klijn, Peter, Legemaat, Monique, Beelen, Anita, van Keimpema, Anton, Garrod, Rachel, Bergsma, Mirella, Paterson, Bill, Stuijfzand, Andrew, van Stel, Henk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008494/
https://www.ncbi.nlm.nih.gov/pubmed/26656349
http://dx.doi.org/10.1097/MD.0000000000002191
_version_ 1782451381032976384
author Klijn, Peter
Legemaat, Monique
Beelen, Anita
van Keimpema, Anton
Garrod, Rachel
Bergsma, Mirella
Paterson, Bill
Stuijfzand, Andrew
van Stel, Henk
author_facet Klijn, Peter
Legemaat, Monique
Beelen, Anita
van Keimpema, Anton
Garrod, Rachel
Bergsma, Mirella
Paterson, Bill
Stuijfzand, Andrew
van Stel, Henk
author_sort Klijn, Peter
collection PubMed
description This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the original LCADL. Measurement properties were evaluated in191 patients with chronic obstructive pulmonary disease (COPD) (70 males; age 62 ± 9 years; FEV(1) 33 ± 10% pred). Construct validity was assessed using disease-specific health status, generic functional status, and functional and peak exercise capacity (Wmax). LCADL was completed twice to assess test–retest reliability. Responsiveness was assessed after 8 to 12 weeks inpatient pulmonary rehabilitation. LCADL correlated significantly with the St. George Respiratory Questionnaire (r = 0.24 to 0.64), functional status (r = 0.45 to 0.82), walking distance (r = −0.3 to −0.58), and Wmax (−0.27 to −0.38) and Wmax % pred (−0.26 to −0.43). Test–retest reliability was high (ICC 0.87 to 0.98). The smallest detectable change for the LCADL total and domain score self-care, domestic, physical, and leisure was 4.5, 2.9, 3.3, 4.9, and 2.2, respectively. Improvement in LCADL after PR correlated significantly with improvement in Chronic Respiratory Questionnaire (−0.43; P < 0.001). The Dutch LCADL is a reliable, valid, and responsive instrument to assess limitations in performing activities of daily living in patients with severe COPD.
format Online
Article
Text
id pubmed-5008494
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-50084942016-09-09 Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD Klijn, Peter Legemaat, Monique Beelen, Anita van Keimpema, Anton Garrod, Rachel Bergsma, Mirella Paterson, Bill Stuijfzand, Andrew van Stel, Henk Medicine (Baltimore) 6700 This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the original LCADL. Measurement properties were evaluated in191 patients with chronic obstructive pulmonary disease (COPD) (70 males; age 62 ± 9 years; FEV(1) 33 ± 10% pred). Construct validity was assessed using disease-specific health status, generic functional status, and functional and peak exercise capacity (Wmax). LCADL was completed twice to assess test–retest reliability. Responsiveness was assessed after 8 to 12 weeks inpatient pulmonary rehabilitation. LCADL correlated significantly with the St. George Respiratory Questionnaire (r = 0.24 to 0.64), functional status (r = 0.45 to 0.82), walking distance (r = −0.3 to −0.58), and Wmax (−0.27 to −0.38) and Wmax % pred (−0.26 to −0.43). Test–retest reliability was high (ICC 0.87 to 0.98). The smallest detectable change for the LCADL total and domain score self-care, domestic, physical, and leisure was 4.5, 2.9, 3.3, 4.9, and 2.2, respectively. Improvement in LCADL after PR correlated significantly with improvement in Chronic Respiratory Questionnaire (−0.43; P < 0.001). The Dutch LCADL is a reliable, valid, and responsive instrument to assess limitations in performing activities of daily living in patients with severe COPD. Wolters Kluwer Health 2015-12-11 /pmc/articles/PMC5008494/ /pubmed/26656349 http://dx.doi.org/10.1097/MD.0000000000002191 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 6700
Klijn, Peter
Legemaat, Monique
Beelen, Anita
van Keimpema, Anton
Garrod, Rachel
Bergsma, Mirella
Paterson, Bill
Stuijfzand, Andrew
van Stel, Henk
Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title_full Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title_fullStr Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title_full_unstemmed Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title_short Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
title_sort validity, reliability, and responsiveness of the dutch version of the london chest activity of daily living scale in patients with severe copd
topic 6700
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008494/
https://www.ncbi.nlm.nih.gov/pubmed/26656349
http://dx.doi.org/10.1097/MD.0000000000002191
work_keys_str_mv AT klijnpeter validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT legemaatmonique validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT beelenanita validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT vankeimpemaanton validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT garrodrachel validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT bergsmamirella validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT patersonbill validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT stuijfzandandrew validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd
AT vanstelhenk validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd