Cargando…
Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD
This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the or...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008494/ https://www.ncbi.nlm.nih.gov/pubmed/26656349 http://dx.doi.org/10.1097/MD.0000000000002191 |
_version_ | 1782451381032976384 |
---|---|
author | Klijn, Peter Legemaat, Monique Beelen, Anita van Keimpema, Anton Garrod, Rachel Bergsma, Mirella Paterson, Bill Stuijfzand, Andrew van Stel, Henk |
author_facet | Klijn, Peter Legemaat, Monique Beelen, Anita van Keimpema, Anton Garrod, Rachel Bergsma, Mirella Paterson, Bill Stuijfzand, Andrew van Stel, Henk |
author_sort | Klijn, Peter |
collection | PubMed |
description | This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the original LCADL. Measurement properties were evaluated in191 patients with chronic obstructive pulmonary disease (COPD) (70 males; age 62 ± 9 years; FEV(1) 33 ± 10% pred). Construct validity was assessed using disease-specific health status, generic functional status, and functional and peak exercise capacity (Wmax). LCADL was completed twice to assess test–retest reliability. Responsiveness was assessed after 8 to 12 weeks inpatient pulmonary rehabilitation. LCADL correlated significantly with the St. George Respiratory Questionnaire (r = 0.24 to 0.64), functional status (r = 0.45 to 0.82), walking distance (r = −0.3 to −0.58), and Wmax (−0.27 to −0.38) and Wmax % pred (−0.26 to −0.43). Test–retest reliability was high (ICC 0.87 to 0.98). The smallest detectable change for the LCADL total and domain score self-care, domestic, physical, and leisure was 4.5, 2.9, 3.3, 4.9, and 2.2, respectively. Improvement in LCADL after PR correlated significantly with improvement in Chronic Respiratory Questionnaire (−0.43; P < 0.001). The Dutch LCADL is a reliable, valid, and responsive instrument to assess limitations in performing activities of daily living in patients with severe COPD. |
format | Online Article Text |
id | pubmed-5008494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-50084942016-09-09 Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD Klijn, Peter Legemaat, Monique Beelen, Anita van Keimpema, Anton Garrod, Rachel Bergsma, Mirella Paterson, Bill Stuijfzand, Andrew van Stel, Henk Medicine (Baltimore) 6700 This study assesses the validity, reliability, and responsiveness of the Dutch version of the London Chest Activity of Daily Living scale (LCADL). The English LCADL version was translated into Dutch and then back-translated to English to check if the translation was conceptually equivalent to the original LCADL. Measurement properties were evaluated in191 patients with chronic obstructive pulmonary disease (COPD) (70 males; age 62 ± 9 years; FEV(1) 33 ± 10% pred). Construct validity was assessed using disease-specific health status, generic functional status, and functional and peak exercise capacity (Wmax). LCADL was completed twice to assess test–retest reliability. Responsiveness was assessed after 8 to 12 weeks inpatient pulmonary rehabilitation. LCADL correlated significantly with the St. George Respiratory Questionnaire (r = 0.24 to 0.64), functional status (r = 0.45 to 0.82), walking distance (r = −0.3 to −0.58), and Wmax (−0.27 to −0.38) and Wmax % pred (−0.26 to −0.43). Test–retest reliability was high (ICC 0.87 to 0.98). The smallest detectable change for the LCADL total and domain score self-care, domestic, physical, and leisure was 4.5, 2.9, 3.3, 4.9, and 2.2, respectively. Improvement in LCADL after PR correlated significantly with improvement in Chronic Respiratory Questionnaire (−0.43; P < 0.001). The Dutch LCADL is a reliable, valid, and responsive instrument to assess limitations in performing activities of daily living in patients with severe COPD. Wolters Kluwer Health 2015-12-11 /pmc/articles/PMC5008494/ /pubmed/26656349 http://dx.doi.org/10.1097/MD.0000000000002191 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0 |
spellingShingle | 6700 Klijn, Peter Legemaat, Monique Beelen, Anita van Keimpema, Anton Garrod, Rachel Bergsma, Mirella Paterson, Bill Stuijfzand, Andrew van Stel, Henk Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title | Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title_full | Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title_fullStr | Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title_full_unstemmed | Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title_short | Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD |
title_sort | validity, reliability, and responsiveness of the dutch version of the london chest activity of daily living scale in patients with severe copd |
topic | 6700 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008494/ https://www.ncbi.nlm.nih.gov/pubmed/26656349 http://dx.doi.org/10.1097/MD.0000000000002191 |
work_keys_str_mv | AT klijnpeter validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT legemaatmonique validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT beelenanita validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT vankeimpemaanton validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT garrodrachel validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT bergsmamirella validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT patersonbill validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT stuijfzandandrew validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd AT vanstelhenk validityreliabilityandresponsivenessofthedutchversionofthelondonchestactivityofdailylivingscaleinpatientswithseverecopd |