Cargando…

Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis

BACKGROUND: As low birthweight (i.e., birthweight < 2500 g) is a major determinant of neonatal mortality and morbidity, the pre-delivery detection of low birthweight is clinically advantageous. This study was performed to determine whether ultrasound is suitable for use in primary screening to de...

Descripción completa

Detalles Bibliográficos
Autor principal: Goto, Eita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008608/
https://www.ncbi.nlm.nih.gov/pubmed/27583924
http://dx.doi.org/10.1097/MD.0000000000004750
_version_ 1782451407505326080
author Goto, Eita
author_facet Goto, Eita
author_sort Goto, Eita
collection PubMed
description BACKGROUND: As low birthweight (i.e., birthweight < 2500 g) is a major determinant of neonatal mortality and morbidity, the pre-delivery detection of low birthweight is clinically advantageous. This study was performed to determine whether ultrasound is suitable for use in primary screening to detect low birthweight newborns. METHODS: The primary outcomes included sensitivity, specificity, and positive and negative likelihood ratios of ultrasound detection of low birthweight newborns. Ten databases, including PubMed, were searched. All English language studies that provided true- and false-positive and true- and false-negative results regarding the pre-delivery ultrasound detection of low birthweight newborns were eligible for inclusion in the analysis. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies. Bivariate diagnostic meta-analysis was performed and hierarchical summary receiver operating characteristic curves were constructed. RESULTS: Studies of relatively good quality were included in the analysis to evaluate crown–rump length (n = 12); femur length (n = 5); formulas of Campbell, Hadlock, and Shepard (n = 9); and uterine artery blood flow (n = 7). All showed low sensitivity (=0.24–0.58) regardless of specificity (=0.60–0.96). The formulas of Campbell, Hadlock, and Shepard were usable for a confirmation strategy only (positive and negative likelihood ratios = 14.8 and 0.44, respectively), but crown–rump or femur length, and uterine artery blood flow were not usable for an exclusion or confirmation strategy (positive and negative likelihood ratios = 1.4–2.8 and 0.71–0.85, respectively). CONCLUSIONS: Primary screening does not have to confirm low birthweight, but should almost always categorize low birthweight as a positive result and exclude normal birthweight. Therefore, ultrasound is not suitable as a primary screening tool to detect low birthweight newborns.
format Online
Article
Text
id pubmed-5008608
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-50086082016-09-10 Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis Goto, Eita Medicine (Baltimore) 5600 BACKGROUND: As low birthweight (i.e., birthweight < 2500 g) is a major determinant of neonatal mortality and morbidity, the pre-delivery detection of low birthweight is clinically advantageous. This study was performed to determine whether ultrasound is suitable for use in primary screening to detect low birthweight newborns. METHODS: The primary outcomes included sensitivity, specificity, and positive and negative likelihood ratios of ultrasound detection of low birthweight newborns. Ten databases, including PubMed, were searched. All English language studies that provided true- and false-positive and true- and false-negative results regarding the pre-delivery ultrasound detection of low birthweight newborns were eligible for inclusion in the analysis. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies. Bivariate diagnostic meta-analysis was performed and hierarchical summary receiver operating characteristic curves were constructed. RESULTS: Studies of relatively good quality were included in the analysis to evaluate crown–rump length (n = 12); femur length (n = 5); formulas of Campbell, Hadlock, and Shepard (n = 9); and uterine artery blood flow (n = 7). All showed low sensitivity (=0.24–0.58) regardless of specificity (=0.60–0.96). The formulas of Campbell, Hadlock, and Shepard were usable for a confirmation strategy only (positive and negative likelihood ratios = 14.8 and 0.44, respectively), but crown–rump or femur length, and uterine artery blood flow were not usable for an exclusion or confirmation strategy (positive and negative likelihood ratios = 1.4–2.8 and 0.71–0.85, respectively). CONCLUSIONS: Primary screening does not have to confirm low birthweight, but should almost always categorize low birthweight as a positive result and exclude normal birthweight. Therefore, ultrasound is not suitable as a primary screening tool to detect low birthweight newborns. Wolters Kluwer Health 2016-09-02 /pmc/articles/PMC5008608/ /pubmed/27583924 http://dx.doi.org/10.1097/MD.0000000000004750 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. http://creativecommons.org/licenses/by-nc-sa/4.0
spellingShingle 5600
Goto, Eita
Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title_full Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title_fullStr Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title_full_unstemmed Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title_short Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
title_sort ultrasound as a primary screening tool for detecting low birthweight newborns: a meta-analysis
topic 5600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5008608/
https://www.ncbi.nlm.nih.gov/pubmed/27583924
http://dx.doi.org/10.1097/MD.0000000000004750
work_keys_str_mv AT gotoeita ultrasoundasaprimaryscreeningtoolfordetectinglowbirthweightnewbornsametaanalysis