Cargando…

Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank

BACKGROUND: More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols opti...

Descripción completa

Detalles Bibliográficos
Autores principales: Aarem, Jeanette, Brunborg, Gunnar, Aas, Kaja K., Harbak, Kari, Taipale, Miia M., Magnus, Per, Knudsen, Gun Peggy, Duale, Nur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5009671/
https://www.ncbi.nlm.nih.gov/pubmed/27587079
http://dx.doi.org/10.1186/s13104-016-2224-y
_version_ 1782451557366759424
author Aarem, Jeanette
Brunborg, Gunnar
Aas, Kaja K.
Harbak, Kari
Taipale, Miia M.
Magnus, Per
Knudsen, Gun Peggy
Duale, Nur
author_facet Aarem, Jeanette
Brunborg, Gunnar
Aas, Kaja K.
Harbak, Kari
Taipale, Miia M.
Magnus, Per
Knudsen, Gun Peggy
Duale, Nur
author_sort Aarem, Jeanette
collection PubMed
description BACKGROUND: More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols optimized for simultaneous isolation of all blood-RNA species (MagMAX RNA Isolation Kit, both manual and semi-automated protocols; and Norgen Preserved Blood RNA kit I); and two protocols optimized for large RNAs only (Tempus Spin RNA, and Tempus 6-port isolation kit). We estimated the following parameters: RNA quality, RNA yield, processing time, cost per sample, and RNA transcript stability of six selected mRNAs and 13 miRNAs using real-time qPCR. FINDINGS: Whole blood samples from adults (n = 59 tubes) and umbilical cord blood (n = 18 tubes) samples collected in Tempus tubes were analyzed. High-quality blood-RNAs with average RIN-values above seven were extracted using all five RNA isolation protocols. The transcript levels of the six selected genes showed minimal variation between the five protocols. Unexplained differences within the transcript levels of the 13 miRNA were observed; however, the 13 miRNAs had similar expression direction and they were within the same order of magnitude. Some differences in the RNA processing time and cost were noted. CONCLUSIONS: Sufficient amounts of high-quality RNA were obtained using all five protocols, and the Tempus blood RNA system therefore seems not to be dependent on one specific RNA isolation method. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13104-016-2224-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5009671
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50096712016-09-03 Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank Aarem, Jeanette Brunborg, Gunnar Aas, Kaja K. Harbak, Kari Taipale, Miia M. Magnus, Per Knudsen, Gun Peggy Duale, Nur BMC Res Notes Short Report BACKGROUND: More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols optimized for simultaneous isolation of all blood-RNA species (MagMAX RNA Isolation Kit, both manual and semi-automated protocols; and Norgen Preserved Blood RNA kit I); and two protocols optimized for large RNAs only (Tempus Spin RNA, and Tempus 6-port isolation kit). We estimated the following parameters: RNA quality, RNA yield, processing time, cost per sample, and RNA transcript stability of six selected mRNAs and 13 miRNAs using real-time qPCR. FINDINGS: Whole blood samples from adults (n = 59 tubes) and umbilical cord blood (n = 18 tubes) samples collected in Tempus tubes were analyzed. High-quality blood-RNAs with average RIN-values above seven were extracted using all five RNA isolation protocols. The transcript levels of the six selected genes showed minimal variation between the five protocols. Unexplained differences within the transcript levels of the 13 miRNA were observed; however, the 13 miRNAs had similar expression direction and they were within the same order of magnitude. Some differences in the RNA processing time and cost were noted. CONCLUSIONS: Sufficient amounts of high-quality RNA were obtained using all five protocols, and the Tempus blood RNA system therefore seems not to be dependent on one specific RNA isolation method. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13104-016-2224-y) contains supplementary material, which is available to authorized users. BioMed Central 2016-09-01 /pmc/articles/PMC5009671/ /pubmed/27587079 http://dx.doi.org/10.1186/s13104-016-2224-y Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Short Report
Aarem, Jeanette
Brunborg, Gunnar
Aas, Kaja K.
Harbak, Kari
Taipale, Miia M.
Magnus, Per
Knudsen, Gun Peggy
Duale, Nur
Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title_full Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title_fullStr Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title_full_unstemmed Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title_short Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank
title_sort comparison of blood rna isolation methods from samples stabilized in tempus tubes and stored at a large human biobank
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5009671/
https://www.ncbi.nlm.nih.gov/pubmed/27587079
http://dx.doi.org/10.1186/s13104-016-2224-y
work_keys_str_mv AT aaremjeanette comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT brunborggunnar comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT aaskajak comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT harbakkari comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT taipalemiiam comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT magnusper comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT knudsengunpeggy comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank
AT dualenur comparisonofbloodrnaisolationmethodsfromsamplesstabilizedintempustubesandstoredatalargehumanbiobank