Cargando…
Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5010276/ https://www.ncbi.nlm.nih.gov/pubmed/27442860 http://dx.doi.org/10.1097/MAT.0000000000000409 |
_version_ | 1782451658723164160 |
---|---|
author | Sibbel, Scott Hunt, Abigail Laplante, Suzanne Beck, Werner Gellens, Mary Brunelli, Steven M. |
author_facet | Sibbel, Scott Hunt, Abigail Laplante, Suzanne Beck, Werner Gellens, Mary Brunelli, Steven M. |
author_sort | Sibbel, Scott |
collection | PubMed |
description | Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations. |
format | Online Article Text |
id | pubmed-5010276 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-50102762016-09-12 Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients Sibbel, Scott Hunt, Abigail Laplante, Suzanne Beck, Werner Gellens, Mary Brunelli, Steven M. ASAIO J Renal\Extracorporeal Blood Treatment Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations. Lippincott Williams & Wilkins 2016-09 2016-08-26 /pmc/articles/PMC5010276/ /pubmed/27442860 http://dx.doi.org/10.1097/MAT.0000000000000409 Text en Copyright © 2016 by the American Society for Artificial Internal Organs This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. |
spellingShingle | Renal\Extracorporeal Blood Treatment Sibbel, Scott Hunt, Abigail Laplante, Suzanne Beck, Werner Gellens, Mary Brunelli, Steven M. Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title | Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title_full | Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title_fullStr | Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title_full_unstemmed | Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title_short | Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients |
title_sort | comparative effectiveness of dialyzers: a longitudinal, propensity score-matched study of incident hemodialysis patients |
topic | Renal\Extracorporeal Blood Treatment |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5010276/ https://www.ncbi.nlm.nih.gov/pubmed/27442860 http://dx.doi.org/10.1097/MAT.0000000000000409 |
work_keys_str_mv | AT sibbelscott comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients AT huntabigail comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients AT laplantesuzanne comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients AT beckwerner comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients AT gellensmary comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients AT brunellistevenm comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients |