Cargando…

Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients

Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1,...

Descripción completa

Detalles Bibliográficos
Autores principales: Sibbel, Scott, Hunt, Abigail, Laplante, Suzanne, Beck, Werner, Gellens, Mary, Brunelli, Steven M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5010276/
https://www.ncbi.nlm.nih.gov/pubmed/27442860
http://dx.doi.org/10.1097/MAT.0000000000000409
_version_ 1782451658723164160
author Sibbel, Scott
Hunt, Abigail
Laplante, Suzanne
Beck, Werner
Gellens, Mary
Brunelli, Steven M.
author_facet Sibbel, Scott
Hunt, Abigail
Laplante, Suzanne
Beck, Werner
Gellens, Mary
Brunelli, Steven M.
author_sort Sibbel, Scott
collection PubMed
description Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations.
format Online
Article
Text
id pubmed-5010276
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-50102762016-09-12 Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients Sibbel, Scott Hunt, Abigail Laplante, Suzanne Beck, Werner Gellens, Mary Brunelli, Steven M. ASAIO J Renal\Extracorporeal Blood Treatment Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations. Lippincott Williams & Wilkins 2016-09 2016-08-26 /pmc/articles/PMC5010276/ /pubmed/27442860 http://dx.doi.org/10.1097/MAT.0000000000000409 Text en Copyright © 2016 by the American Society for Artificial Internal Organs This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.
spellingShingle Renal\Extracorporeal Blood Treatment
Sibbel, Scott
Hunt, Abigail
Laplante, Suzanne
Beck, Werner
Gellens, Mary
Brunelli, Steven M.
Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title_full Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title_fullStr Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title_full_unstemmed Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title_short Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
title_sort comparative effectiveness of dialyzers: a longitudinal, propensity score-matched study of incident hemodialysis patients
topic Renal\Extracorporeal Blood Treatment
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5010276/
https://www.ncbi.nlm.nih.gov/pubmed/27442860
http://dx.doi.org/10.1097/MAT.0000000000000409
work_keys_str_mv AT sibbelscott comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients
AT huntabigail comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients
AT laplantesuzanne comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients
AT beckwerner comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients
AT gellensmary comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients
AT brunellistevenm comparativeeffectivenessofdialyzersalongitudinalpropensityscorematchedstudyofincidenthemodialysispatients