Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements

[Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images cap...

Descripción completa

Detalles Bibliográficos
Autores principales: Tozawa, Ryosuke, Katoh, Munenori, Aramaki, Hidefumi, Kawasaki, Tsubasa, Nishikawa, Yuichi, Kumamoto, Tsuneo, Fujinawa, Osamu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5011563/
https://www.ncbi.nlm.nih.gov/pubmed/27630399
http://dx.doi.org/10.1589/jpts.28.2210
_version_ 1782451849662562304
author Tozawa, Ryosuke
Katoh, Munenori
Aramaki, Hidefumi
Kawasaki, Tsubasa
Nishikawa, Yuichi
Kumamoto, Tsuneo
Fujinawa, Osamu
author_facet Tozawa, Ryosuke
Katoh, Munenori
Aramaki, Hidefumi
Kawasaki, Tsubasa
Nishikawa, Yuichi
Kumamoto, Tsuneo
Fujinawa, Osamu
author_sort Tozawa, Ryosuke
collection PubMed
description [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person.
format Online
Article
Text
id pubmed-5011563
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-50115632016-09-14 Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements Tozawa, Ryosuke Katoh, Munenori Aramaki, Hidefumi Kawasaki, Tsubasa Nishikawa, Yuichi Kumamoto, Tsuneo Fujinawa, Osamu J Phys Ther Sci Original Article [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person. The Society of Physical Therapy Science 2016-08-31 2016-08 /pmc/articles/PMC5011563/ /pubmed/27630399 http://dx.doi.org/10.1589/jpts.28.2210 Text en 2016©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original Article
Tozawa, Ryosuke
Katoh, Munenori
Aramaki, Hidefumi
Kawasaki, Tsubasa
Nishikawa, Yuichi
Kumamoto, Tsuneo
Fujinawa, Osamu
Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title_full Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title_fullStr Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title_full_unstemmed Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title_short Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
title_sort absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5011563/
https://www.ncbi.nlm.nih.gov/pubmed/27630399
http://dx.doi.org/10.1589/jpts.28.2210
work_keys_str_mv AT tozawaryosuke absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT katohmunenori absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT aramakihidefumi absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT kawasakitsubasa absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT nishikawayuichi absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT kumamototsuneo absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements
AT fujinawaosamu absoluteandrelativereliabilityoflumbarinterspinousprocessultrasoundimagingmeasurements