Cargando…

External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia

Tuberculosis (TB) is still a public health problem in sub Saharan African countries. In resource-limited settings, TB diagnosis relies on sputum smear microscopy, with low and variable sensitivities, especially in paucibacillary pediatric and HIV-associated TB patients. Tuberculosis microscopy cente...

Descripción completa

Detalles Bibliográficos
Autores principales: Mosissa, Lemi, Kebede, Abebaw, Mindaye, Tedla, Getahun, Muluwork, Tulu, Sisay, Desta, Kassu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The African Field Epidemiology Network 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012771/
https://www.ncbi.nlm.nih.gov/pubmed/27642463
http://dx.doi.org/10.11604/pamj.2016.24.125.7459
_version_ 1782452047836086272
author Mosissa, Lemi
Kebede, Abebaw
Mindaye, Tedla
Getahun, Muluwork
Tulu, Sisay
Desta, Kassu
author_facet Mosissa, Lemi
Kebede, Abebaw
Mindaye, Tedla
Getahun, Muluwork
Tulu, Sisay
Desta, Kassu
author_sort Mosissa, Lemi
collection PubMed
description Tuberculosis (TB) is still a public health problem in sub Saharan African countries. In resource-limited settings, TB diagnosis relies on sputum smear microscopy, with low and variable sensitivities, especially in paucibacillary pediatric and HIV-associated TB patients. Tuberculosis microscopy centers have several weaknesses like overworking, insufficiently trained personnel, inconsistent reagent supplies, and poorly maintained equipments; thus, there is a critical need for investments in laboratory infrastructure, capacity building, and quality assurance schemes. The performance of TB microscopy centers in the private health facilities in Addis Ababa is not known so far. The main objective of the study was to assess laboratory performance of acid fast bacilli (AFB) smear microscopy and its associated factors in selected private health facilities in Addis Ababa, Ethiopia. A cross-sectional study was conducted in 33 selected private health facilities of Addis Ababa, Ethiopia comprising 7 hospitals, 2 NGO health centers, 23 higher clinics and 1 diagnostic laboratory that provide AFB smear microscopy services. The study was conducted from January to April 2014. A total of 283 stained sputum smears were randomly collected from participant laboratories for blinded rechecking, 320 panel slides were sent to 32 microscopy centers to evaluate their performance on AFB reading, staining and reporting. Checklists were used to assess quality issues of laboratories. Data were captured, cleaned, and analyzed using SPSS version 16.0; χ(2) tests, kappa statistics were used for comparison purpose. P value < 0.05 considered statistically significant. Among the 32 participant laboratories, 2-scored 100%, 15 scored 80-95% & the remaining 15 scored 50-75% for overall proficiency test performance. There were 10 (3.15%) major errors and 121 (37.8%) minor errors. The sensitivity, specificity, PPV and NPV of panel reading by microscopy centers were 89%, 96%, 96%, and 90% respectively. Out of 283 randomly selected slides for blind rechecking, 11 (3.9%) slides interpreted falsely for AFB, with overall agreement of 97.5%, sensitivity of 88.4% and specificity of 99.3%. In terms of slide quality assessment, 71.6% of AFB slides were graded as good for evenness, cleanness, thickness, size, staining and labeling. The performance score for AFB slide evenness was 56.9% (161 slides) and for labeling quality was 90.8% (257 slides); having significant difference in slide quality (p value < 0.05). On-site evaluation indicated problems in terms of infrastructure, standard operating procedure, reagent quality; equipment maintenance, data management and training issues. Most of the health facilities had poor maintenance scheme for microscope (53.5%) and poor inventory management (25.0%) system. Microscopy centers that scored a proficiency of 75.5%; which is below the acceptable minimum score of 80% and an overall error rate of 3.9% for blinded rechecking needs attention. Moreover, there are gaps identified through on site assessment including poor SOP, reagent quality, equipment maintenance, data management & lack of updated training on AFB microscopy techniques, requiring a concerted effort to alleviate the bottle neck problems and strengthening the public private partnership to control TB.
format Online
Article
Text
id pubmed-5012771
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The African Field Epidemiology Network
record_format MEDLINE/PubMed
spelling pubmed-50127712016-09-16 External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia Mosissa, Lemi Kebede, Abebaw Mindaye, Tedla Getahun, Muluwork Tulu, Sisay Desta, Kassu Pan Afr Med J Case Series Tuberculosis (TB) is still a public health problem in sub Saharan African countries. In resource-limited settings, TB diagnosis relies on sputum smear microscopy, with low and variable sensitivities, especially in paucibacillary pediatric and HIV-associated TB patients. Tuberculosis microscopy centers have several weaknesses like overworking, insufficiently trained personnel, inconsistent reagent supplies, and poorly maintained equipments; thus, there is a critical need for investments in laboratory infrastructure, capacity building, and quality assurance schemes. The performance of TB microscopy centers in the private health facilities in Addis Ababa is not known so far. The main objective of the study was to assess laboratory performance of acid fast bacilli (AFB) smear microscopy and its associated factors in selected private health facilities in Addis Ababa, Ethiopia. A cross-sectional study was conducted in 33 selected private health facilities of Addis Ababa, Ethiopia comprising 7 hospitals, 2 NGO health centers, 23 higher clinics and 1 diagnostic laboratory that provide AFB smear microscopy services. The study was conducted from January to April 2014. A total of 283 stained sputum smears were randomly collected from participant laboratories for blinded rechecking, 320 panel slides were sent to 32 microscopy centers to evaluate their performance on AFB reading, staining and reporting. Checklists were used to assess quality issues of laboratories. Data were captured, cleaned, and analyzed using SPSS version 16.0; χ(2) tests, kappa statistics were used for comparison purpose. P value < 0.05 considered statistically significant. Among the 32 participant laboratories, 2-scored 100%, 15 scored 80-95% & the remaining 15 scored 50-75% for overall proficiency test performance. There were 10 (3.15%) major errors and 121 (37.8%) minor errors. The sensitivity, specificity, PPV and NPV of panel reading by microscopy centers were 89%, 96%, 96%, and 90% respectively. Out of 283 randomly selected slides for blind rechecking, 11 (3.9%) slides interpreted falsely for AFB, with overall agreement of 97.5%, sensitivity of 88.4% and specificity of 99.3%. In terms of slide quality assessment, 71.6% of AFB slides were graded as good for evenness, cleanness, thickness, size, staining and labeling. The performance score for AFB slide evenness was 56.9% (161 slides) and for labeling quality was 90.8% (257 slides); having significant difference in slide quality (p value < 0.05). On-site evaluation indicated problems in terms of infrastructure, standard operating procedure, reagent quality; equipment maintenance, data management and training issues. Most of the health facilities had poor maintenance scheme for microscope (53.5%) and poor inventory management (25.0%) system. Microscopy centers that scored a proficiency of 75.5%; which is below the acceptable minimum score of 80% and an overall error rate of 3.9% for blinded rechecking needs attention. Moreover, there are gaps identified through on site assessment including poor SOP, reagent quality, equipment maintenance, data management & lack of updated training on AFB microscopy techniques, requiring a concerted effort to alleviate the bottle neck problems and strengthening the public private partnership to control TB. The African Field Epidemiology Network 2016-06-09 /pmc/articles/PMC5012771/ /pubmed/27642463 http://dx.doi.org/10.11604/pamj.2016.24.125.7459 Text en © Lemi Mosissa et al. http://creativecommons.org/licenses/by/2.0/ The Pan African Medical Journal - ISSN 1937-8688. This is an Open Access article distributed under the terms of the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Series
Mosissa, Lemi
Kebede, Abebaw
Mindaye, Tedla
Getahun, Muluwork
Tulu, Sisay
Desta, Kassu
External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title_full External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title_fullStr External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title_full_unstemmed External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title_short External quality assessment of AFB smear microscopy performances and its associated factors in selected private health facilities in Addis Ababa, Ethiopia
title_sort external quality assessment of afb smear microscopy performances and its associated factors in selected private health facilities in addis ababa, ethiopia
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012771/
https://www.ncbi.nlm.nih.gov/pubmed/27642463
http://dx.doi.org/10.11604/pamj.2016.24.125.7459
work_keys_str_mv AT mosissalemi externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia
AT kebedeabebaw externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia
AT mindayetedla externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia
AT getahunmuluwork externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia
AT tulusisay externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia
AT destakassu externalqualityassessmentofafbsmearmicroscopyperformancesanditsassociatedfactorsinselectedprivatehealthfacilitiesinaddisababaethiopia