Cargando…
Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optica...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012967/ https://www.ncbi.nlm.nih.gov/pubmed/27606262 http://dx.doi.org/10.5535/arm.2016.40.4.568 |
_version_ | 1782452076993839104 |
---|---|
author | Song, Young Seop Yang, Kyung Yong Youn, Kibum Yoon, Chiyul Yeom, Jiwoon Hwang, Hyeoncheol Lee, Jehee Kim, Keewon |
author_facet | Song, Young Seop Yang, Kyung Yong Youn, Kibum Yoon, Chiyul Yeom, Jiwoon Hwang, Hyeoncheol Lee, Jehee Kim, Keewon |
author_sort | Song, Young Seop |
collection | PubMed |
description | OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). RESULTS: MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. CONCLUSION: Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range. |
format | Online Article Text |
id | pubmed-5012967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-50129672016-09-07 Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System Song, Young Seop Yang, Kyung Yong Youn, Kibum Yoon, Chiyul Yeom, Jiwoon Hwang, Hyeoncheol Lee, Jehee Kim, Keewon Ann Rehabil Med Original Article OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). RESULTS: MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. CONCLUSION: Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range. Korean Academy of Rehabilitation Medicine 2016-08 2016-08-24 /pmc/articles/PMC5012967/ /pubmed/27606262 http://dx.doi.org/10.5535/arm.2016.40.4.568 Text en Copyright © 2016 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Song, Young Seop Yang, Kyung Yong Youn, Kibum Yoon, Chiyul Yeom, Jiwoon Hwang, Hyeoncheol Lee, Jehee Kim, Keewon Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title | Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title_full | Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title_fullStr | Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title_full_unstemmed | Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title_short | Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System |
title_sort | validation of attitude and heading reference system and microsoft kinect for continuous measurement of cervical range of motion compared to the optical motion capture system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012967/ https://www.ncbi.nlm.nih.gov/pubmed/27606262 http://dx.doi.org/10.5535/arm.2016.40.4.568 |
work_keys_str_mv | AT songyoungseop validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT yangkyungyong validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT younkibum validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT yoonchiyul validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT yeomjiwoon validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT hwanghyeoncheol validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT leejehee validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem AT kimkeewon validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem |