Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System

OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optica...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Young Seop, Yang, Kyung Yong, Youn, Kibum, Yoon, Chiyul, Yeom, Jiwoon, Hwang, Hyeoncheol, Lee, Jehee, Kim, Keewon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Rehabilitation Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012967/
https://www.ncbi.nlm.nih.gov/pubmed/27606262
http://dx.doi.org/10.5535/arm.2016.40.4.568
_version_ 1782452076993839104
author Song, Young Seop
Yang, Kyung Yong
Youn, Kibum
Yoon, Chiyul
Yeom, Jiwoon
Hwang, Hyeoncheol
Lee, Jehee
Kim, Keewon
author_facet Song, Young Seop
Yang, Kyung Yong
Youn, Kibum
Yoon, Chiyul
Yeom, Jiwoon
Hwang, Hyeoncheol
Lee, Jehee
Kim, Keewon
author_sort Song, Young Seop
collection PubMed
description OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). RESULTS: MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. CONCLUSION: Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.
format Online
Article
Text
id pubmed-5012967
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Korean Academy of Rehabilitation Medicine
record_format MEDLINE/PubMed
spelling pubmed-50129672016-09-07 Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System Song, Young Seop Yang, Kyung Yong Youn, Kibum Yoon, Chiyul Yeom, Jiwoon Hwang, Hyeoncheol Lee, Jehee Kim, Keewon Ann Rehabil Med Original Article OBJECTIVE: To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). METHODS: Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). RESULTS: MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. CONCLUSION: Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range. Korean Academy of Rehabilitation Medicine 2016-08 2016-08-24 /pmc/articles/PMC5012967/ /pubmed/27606262 http://dx.doi.org/10.5535/arm.2016.40.4.568 Text en Copyright © 2016 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Song, Young Seop
Yang, Kyung Yong
Youn, Kibum
Yoon, Chiyul
Yeom, Jiwoon
Hwang, Hyeoncheol
Lee, Jehee
Kim, Keewon
Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title_full Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title_fullStr Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title_full_unstemmed Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title_short Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System
title_sort validation of attitude and heading reference system and microsoft kinect for continuous measurement of cervical range of motion compared to the optical motion capture system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5012967/
https://www.ncbi.nlm.nih.gov/pubmed/27606262
http://dx.doi.org/10.5535/arm.2016.40.4.568
work_keys_str_mv AT songyoungseop validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT yangkyungyong validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT younkibum validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT yoonchiyul validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT yeomjiwoon validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT hwanghyeoncheol validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT leejehee validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem
AT kimkeewon validationofattitudeandheadingreferencesystemandmicrosoftkinectforcontinuousmeasurementofcervicalrangeofmotioncomparedtotheopticalmotioncapturesystem