Cargando…

Surgical, functional and audiological evaluation of new Baha(®) Attract system implantations

Bone-anchored hearing aids are well-established solutions for treatment of hearing-impaired patients. However, classical systems with percutaneous abutments have disadvantages concerning aesthetics, hygiene and adverse soft tissue reactions. The study aimed to evaluate surgical, functional and audio...

Descripción completa

Detalles Bibliográficos
Autores principales: Gawęcki, Wojciech, Stieler, Olgierd Maciej, Balcerowiak, Andrzej, Komar, Dariusz, Gibasiewicz, Renata, Karlik, Michał, Szyfter-Harris, Joanna, Wróbel, Maciej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5014880/
https://www.ncbi.nlm.nih.gov/pubmed/26899281
http://dx.doi.org/10.1007/s00405-016-3917-5
Descripción
Sumario:Bone-anchored hearing aids are well-established solutions for treatment of hearing-impaired patients. However, classical systems with percutaneous abutments have disadvantages concerning aesthetics, hygiene and adverse soft tissue reactions. The study aimed to evaluate surgical, functional and audiological results of a new Baha(®) Attract system, in which the sound processor is attached by magnetic force. Twenty patients implanted with a Baha(®) Attract system were divided into two groups: A—bilateral mixed and conductive hearing loss, B—single-sided deafness, and evaluated during a 6-month follow-up. Parameters analysed comprised: (1) surgery and wound healing, (2) postoperative functional results (GBI, APHAB and BAHU questionnaires), (3) audiological results (free field speech in noise audiometry in two situations: with signal from implant side and from contralateral side). Obtained results revealed: mean time of surgery—44 min, soft tissue reduction—30 %, bone polishing—20 %, haematoma—10 %. Functional results showed: GBI total score—29.6 points, APHAB global score mean gain—23.5 %, BAHU ‘good or very good’ score for: aesthetic—85 %, hygiene—100 %, ease of placing the processor—100 %, stability of attraction—75 %. Audiological results—mean gain for the two analysed situations: 32.9 % (group A—36.5 %, group B—27.5 %). To conclude, the data obtained prove the safety and effectiveness of the Baha(®) Attract system in patients with conductive and mixed hearing loss as well as in patients with single-sided deafness. Cosmetic aspects are highly acceptable and the idea of Attract itself is important for patients with limited manual dexterity.