Cargando…

Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules

BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The f...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yingxian, Wu, Hao, Zhou, Qing, Gou, Jiamei, Xu, Jinmei, Liu, Yan, Chen, Qin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015597/
https://www.ncbi.nlm.nih.gov/pubmed/27580248
http://dx.doi.org/10.12659/MSM.897011
_version_ 1782452465798479872
author Liu, Yingxian
Wu, Hao
Zhou, Qing
Gou, Jiamei
Xu, Jinmei
Liu, Yan
Chen, Qin
author_facet Liu, Yingxian
Wu, Hao
Zhou, Qing
Gou, Jiamei
Xu, Jinmei
Liu, Yan
Chen, Qin
author_sort Liu, Yingxian
collection PubMed
description BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The features of conventional US and CEUS ion 102 case of thyroid micronodule samples, which were diagnosed based on pathological and clinical examination, were retrospectively analyzed. Logistic regression analysis was used to analyze the diagnostic accuracy in malignant thyroid micronodules. Receiver operator characteristic (ROC) curve was used to assess the performance of those 2 technologies. RESULTS: A significant difference in age was found between the benign and malignant groups. The benign and malignant groups showed significant differences in shape, margin, aspect ratio (A/T) ≥1, microcalcification, suspicious lymph gland, enhancement time, enhancement pattern, enhancement intensity, nodule sizes, enhancement margins, and rim-like enhancement. Logistic regression analysis of conventional US showed that A/T ≥1, irregular shape, microcalcification, and suspicious lymph glands are risk factors for thyroid micronodules, while logistic regression analysis of CEUS showed that slow enhancement time and absence of rim-like enhancement are risk factors for thyroid micronodules. Logistic regression analysis of conventional US combined with CEUS demonstrated that A/T ≥1, microcalcification, suspicious lymph gland, slow enhancement time, and absence with rim-like enhancement are risk factors. The ROC curve for conventional US, CEUS, and conventional US combined with CEUS were 90.0%, 90.7%, 99.0%, respectively. CONCLUSIONS: Our results show that conventional US combined with CEUS had superior diagnostic performance for TI-RADS 3 and 4 thyroid micronodules compared with conventional US and CEUS alone.
format Online
Article
Text
id pubmed-5015597
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-50155972016-09-19 Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules Liu, Yingxian Wu, Hao Zhou, Qing Gou, Jiamei Xu, Jinmei Liu, Yan Chen, Qin Med Sci Monit Diagnostic Techniques BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The features of conventional US and CEUS ion 102 case of thyroid micronodule samples, which were diagnosed based on pathological and clinical examination, were retrospectively analyzed. Logistic regression analysis was used to analyze the diagnostic accuracy in malignant thyroid micronodules. Receiver operator characteristic (ROC) curve was used to assess the performance of those 2 technologies. RESULTS: A significant difference in age was found between the benign and malignant groups. The benign and malignant groups showed significant differences in shape, margin, aspect ratio (A/T) ≥1, microcalcification, suspicious lymph gland, enhancement time, enhancement pattern, enhancement intensity, nodule sizes, enhancement margins, and rim-like enhancement. Logistic regression analysis of conventional US showed that A/T ≥1, irregular shape, microcalcification, and suspicious lymph glands are risk factors for thyroid micronodules, while logistic regression analysis of CEUS showed that slow enhancement time and absence of rim-like enhancement are risk factors for thyroid micronodules. Logistic regression analysis of conventional US combined with CEUS demonstrated that A/T ≥1, microcalcification, suspicious lymph gland, slow enhancement time, and absence with rim-like enhancement are risk factors. The ROC curve for conventional US, CEUS, and conventional US combined with CEUS were 90.0%, 90.7%, 99.0%, respectively. CONCLUSIONS: Our results show that conventional US combined with CEUS had superior diagnostic performance for TI-RADS 3 and 4 thyroid micronodules compared with conventional US and CEUS alone. International Scientific Literature, Inc. 2016-08-31 /pmc/articles/PMC5015597/ /pubmed/27580248 http://dx.doi.org/10.12659/MSM.897011 Text en © Med Sci Monit, 2016 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
spellingShingle Diagnostic Techniques
Liu, Yingxian
Wu, Hao
Zhou, Qing
Gou, Jiamei
Xu, Jinmei
Liu, Yan
Chen, Qin
Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title_full Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title_fullStr Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title_full_unstemmed Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title_short Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
title_sort diagnostic value of conventional ultrasonography combined with contrast-enhanced ultrasonography in thyroid imaging reporting and data system (ti-rads) 3 and 4 thyroid micronodules
topic Diagnostic Techniques
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015597/
https://www.ncbi.nlm.nih.gov/pubmed/27580248
http://dx.doi.org/10.12659/MSM.897011
work_keys_str_mv AT liuyingxian diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT wuhao diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT zhouqing diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT goujiamei diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT xujinmei diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT liuyan diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules
AT chenqin diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules