Cargando…
Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules
BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The f...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015597/ https://www.ncbi.nlm.nih.gov/pubmed/27580248 http://dx.doi.org/10.12659/MSM.897011 |
_version_ | 1782452465798479872 |
---|---|
author | Liu, Yingxian Wu, Hao Zhou, Qing Gou, Jiamei Xu, Jinmei Liu, Yan Chen, Qin |
author_facet | Liu, Yingxian Wu, Hao Zhou, Qing Gou, Jiamei Xu, Jinmei Liu, Yan Chen, Qin |
author_sort | Liu, Yingxian |
collection | PubMed |
description | BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The features of conventional US and CEUS ion 102 case of thyroid micronodule samples, which were diagnosed based on pathological and clinical examination, were retrospectively analyzed. Logistic regression analysis was used to analyze the diagnostic accuracy in malignant thyroid micronodules. Receiver operator characteristic (ROC) curve was used to assess the performance of those 2 technologies. RESULTS: A significant difference in age was found between the benign and malignant groups. The benign and malignant groups showed significant differences in shape, margin, aspect ratio (A/T) ≥1, microcalcification, suspicious lymph gland, enhancement time, enhancement pattern, enhancement intensity, nodule sizes, enhancement margins, and rim-like enhancement. Logistic regression analysis of conventional US showed that A/T ≥1, irregular shape, microcalcification, and suspicious lymph glands are risk factors for thyroid micronodules, while logistic regression analysis of CEUS showed that slow enhancement time and absence of rim-like enhancement are risk factors for thyroid micronodules. Logistic regression analysis of conventional US combined with CEUS demonstrated that A/T ≥1, microcalcification, suspicious lymph gland, slow enhancement time, and absence with rim-like enhancement are risk factors. The ROC curve for conventional US, CEUS, and conventional US combined with CEUS were 90.0%, 90.7%, 99.0%, respectively. CONCLUSIONS: Our results show that conventional US combined with CEUS had superior diagnostic performance for TI-RADS 3 and 4 thyroid micronodules compared with conventional US and CEUS alone. |
format | Online Article Text |
id | pubmed-5015597 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-50155972016-09-19 Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules Liu, Yingxian Wu, Hao Zhou, Qing Gou, Jiamei Xu, Jinmei Liu, Yan Chen, Qin Med Sci Monit Diagnostic Techniques BACKGROUND: The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL/METHODS: The features of conventional US and CEUS ion 102 case of thyroid micronodule samples, which were diagnosed based on pathological and clinical examination, were retrospectively analyzed. Logistic regression analysis was used to analyze the diagnostic accuracy in malignant thyroid micronodules. Receiver operator characteristic (ROC) curve was used to assess the performance of those 2 technologies. RESULTS: A significant difference in age was found between the benign and malignant groups. The benign and malignant groups showed significant differences in shape, margin, aspect ratio (A/T) ≥1, microcalcification, suspicious lymph gland, enhancement time, enhancement pattern, enhancement intensity, nodule sizes, enhancement margins, and rim-like enhancement. Logistic regression analysis of conventional US showed that A/T ≥1, irregular shape, microcalcification, and suspicious lymph glands are risk factors for thyroid micronodules, while logistic regression analysis of CEUS showed that slow enhancement time and absence of rim-like enhancement are risk factors for thyroid micronodules. Logistic regression analysis of conventional US combined with CEUS demonstrated that A/T ≥1, microcalcification, suspicious lymph gland, slow enhancement time, and absence with rim-like enhancement are risk factors. The ROC curve for conventional US, CEUS, and conventional US combined with CEUS were 90.0%, 90.7%, 99.0%, respectively. CONCLUSIONS: Our results show that conventional US combined with CEUS had superior diagnostic performance for TI-RADS 3 and 4 thyroid micronodules compared with conventional US and CEUS alone. International Scientific Literature, Inc. 2016-08-31 /pmc/articles/PMC5015597/ /pubmed/27580248 http://dx.doi.org/10.12659/MSM.897011 Text en © Med Sci Monit, 2016 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) |
spellingShingle | Diagnostic Techniques Liu, Yingxian Wu, Hao Zhou, Qing Gou, Jiamei Xu, Jinmei Liu, Yan Chen, Qin Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title | Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title_full | Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title_fullStr | Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title_full_unstemmed | Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title_short | Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules |
title_sort | diagnostic value of conventional ultrasonography combined with contrast-enhanced ultrasonography in thyroid imaging reporting and data system (ti-rads) 3 and 4 thyroid micronodules |
topic | Diagnostic Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015597/ https://www.ncbi.nlm.nih.gov/pubmed/27580248 http://dx.doi.org/10.12659/MSM.897011 |
work_keys_str_mv | AT liuyingxian diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT wuhao diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT zhouqing diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT goujiamei diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT xujinmei diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT liuyan diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules AT chenqin diagnosticvalueofconventionalultrasonographycombinedwithcontrastenhancedultrasonographyinthyroidimagingreportinganddatasystemtirads3and4thyroidmicronodules |