Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry

PURPOSE: To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS: The subjects included children with suspected field defects (n = 10, age 5–15 years), adults with field de...

Descripción completa

Detalles Bibliográficos
Autores principales: Murray, Ian C., Cameron, Lorraine A., McTrusty, Alice D., Perperidis, Antonios, Brash, Harry M., Fleck, Brian W., Minns, Robert A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015923/
https://www.ncbi.nlm.nih.gov/pubmed/27617181
http://dx.doi.org/10.1167/tvst.5.4.15
_version_ 1782452509396172800
author Murray, Ian C.
Cameron, Lorraine A.
McTrusty, Alice D.
Perperidis, Antonios
Brash, Harry M.
Fleck, Brian W.
Minns, Robert A.
author_facet Murray, Ian C.
Cameron, Lorraine A.
McTrusty, Alice D.
Perperidis, Antonios
Brash, Harry M.
Fleck, Brian W.
Minns, Robert A.
author_sort Murray, Ian C.
collection PubMed
description PURPOSE: To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS: The subjects included children with suspected field defects (n = 10, age 5–15 years), adults with field defects (n = 33, age 39–78 years), healthy children (n = 12, age 6–14 years), and healthy adults (n = 30, age 16–61 years). The test protocol comprised repeat suprathreshold SVOP and HFA testing with the C-40 test pattern. Feasibility was assessed by protocol completeness. Sensitivity, specificity, and accuracy of SVOP was established by comparison with reliable HFA tests in two ways: (1) visual field pattern results (normal/abnormal), and (2) individual test point outcomes (seen/unseen). Repeatability of each test type was assessed using Cohen's kappa coefficient. RESULTS: Of subjects, 82% completed a full protocol. Poor reliability of HFA testing in child patients limited the robustness of comparisons in this group. Sensitivity, specificity, and accuracy across all groups when analyzing the visual field pattern results was 90.9%, 88.5%, and 89.0%, respectively, and was 69.1%, 96.9%, and 95.0%, respectively, when analyzing the individual test points. Cohen's kappa coefficient for repeatability of SVOP and HFA was excellent (0.87 and 0.88, respectively) when assessing visual field pattern results, and substantial (0.62 and 0.74, respectively) when assessing test point outcomes. CONCLUSIONS: SVOP was accurate in this group of adults. Further studies are required to assess SVOP in child patient groups. TRANSLATIONAL RELEVANCE: SVOP technology is still in its infancy but is used in a number of centers. It will undergo iterative improvements and this study provides a benchmark for future iterations.
format Online
Article
Text
id pubmed-5015923
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-50159232016-09-09 Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry Murray, Ian C. Cameron, Lorraine A. McTrusty, Alice D. Perperidis, Antonios Brash, Harry M. Fleck, Brian W. Minns, Robert A. Transl Vis Sci Technol Articles PURPOSE: To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS: The subjects included children with suspected field defects (n = 10, age 5–15 years), adults with field defects (n = 33, age 39–78 years), healthy children (n = 12, age 6–14 years), and healthy adults (n = 30, age 16–61 years). The test protocol comprised repeat suprathreshold SVOP and HFA testing with the C-40 test pattern. Feasibility was assessed by protocol completeness. Sensitivity, specificity, and accuracy of SVOP was established by comparison with reliable HFA tests in two ways: (1) visual field pattern results (normal/abnormal), and (2) individual test point outcomes (seen/unseen). Repeatability of each test type was assessed using Cohen's kappa coefficient. RESULTS: Of subjects, 82% completed a full protocol. Poor reliability of HFA testing in child patients limited the robustness of comparisons in this group. Sensitivity, specificity, and accuracy across all groups when analyzing the visual field pattern results was 90.9%, 88.5%, and 89.0%, respectively, and was 69.1%, 96.9%, and 95.0%, respectively, when analyzing the individual test points. Cohen's kappa coefficient for repeatability of SVOP and HFA was excellent (0.87 and 0.88, respectively) when assessing visual field pattern results, and substantial (0.62 and 0.74, respectively) when assessing test point outcomes. CONCLUSIONS: SVOP was accurate in this group of adults. Further studies are required to assess SVOP in child patient groups. TRANSLATIONAL RELEVANCE: SVOP technology is still in its infancy but is used in a number of centers. It will undergo iterative improvements and this study provides a benchmark for future iterations. The Association for Research in Vision and Ophthalmology 2016-08-31 /pmc/articles/PMC5015923/ /pubmed/27617181 http://dx.doi.org/10.1167/tvst.5.4.15 Text en http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Articles
Murray, Ian C.
Cameron, Lorraine A.
McTrusty, Alice D.
Perperidis, Antonios
Brash, Harry M.
Fleck, Brian W.
Minns, Robert A.
Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title_full Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title_fullStr Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title_full_unstemmed Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title_short Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry
title_sort feasibility, accuracy, and repeatability of suprathreshold saccadic vector optokinetic perimetry
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015923/
https://www.ncbi.nlm.nih.gov/pubmed/27617181
http://dx.doi.org/10.1167/tvst.5.4.15
work_keys_str_mv AT murrayianc feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT cameronlorrainea feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT mctrustyaliced feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT perperidisantonios feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT brashharrym feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT fleckbrianw feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry
AT minnsroberta feasibilityaccuracyandrepeatabilityofsuprathresholdsaccadicvectoroptokineticperimetry