Pulse pressure variation shows a direct linear correlation with tidal volume in anesthetized healthy patients
BACKGROUND: The settings of mechanical ventilation, like tidal volume (VT), occasionally need to be adjusted in the process of anesthesia for some special reasons. The aim of this study was therefore to assess the relationship between pulse pressure variations (PPVs) in different settings of VT in a...
Autores principales: | Liu, Yi, Lou, Jing-sheng, Mi, Wei-dong, Yuan, Wei-xiu, Fu, Qiang, Wang, Min, Qu, Jing |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017055/ https://www.ncbi.nlm.nih.gov/pubmed/27609188 http://dx.doi.org/10.1186/s12871-016-0233-y |
Ejemplares similares
-
Should pulse pressure variation be indexed to tidal volume?
por: Vistisen, S, et al.
Publicado: (2009) -
Use of ‘tidal volume challenge’ to improve the reliability of pulse pressure variation
por: Myatra, Sheila Nainan, et al.
Publicado: (2017) -
Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension
por: Díaz, F., et al.
Publicado: (2015) -
Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
por: de Oliveira-Costa, Clarice Daniele Alves, et al.
Publicado: (2012) -
Does tidal volume challenge improve the feasibility of pulse pressure variation in patients mechanically ventilated at low tidal volumes? A systematic review and meta-analysis
por: Wang, Xiaoying, et al.
Publicado: (2023)