Cargando…

Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus

OBJECTIVES: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. METHODS: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakista...

Descripción completa

Detalles Bibliográficos
Autores principales: Zulqarnain, Arif, Younas, Muhammad, Waqar, Tariq, Beg, Ahsan, Asma, Touseef, Baig, Mirza Ahmad Raza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017114/
https://www.ncbi.nlm.nih.gov/pubmed/27648051
http://dx.doi.org/10.12669/pjms.324.10048
_version_ 1782452686310866944
author Zulqarnain, Arif
Younas, Muhammad
Waqar, Tariq
Beg, Ahsan
Asma, Touseef
Baig, Mirza Ahmad Raza
author_facet Zulqarnain, Arif
Younas, Muhammad
Waqar, Tariq
Beg, Ahsan
Asma, Touseef
Baig, Mirza Ahmad Raza
author_sort Zulqarnain, Arif
collection PubMed
description OBJECTIVES: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. METHODS: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. RESULTS: There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. CONCLUSION: The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.
format Online
Article
Text
id pubmed-5017114
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Professional Medical Publications
record_format MEDLINE/PubMed
spelling pubmed-50171142016-09-19 Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus Zulqarnain, Arif Younas, Muhammad Waqar, Tariq Beg, Ahsan Asma, Touseef Baig, Mirza Ahmad Raza Pak J Med Sci Original Article OBJECTIVES: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. METHODS: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. RESULTS: There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. CONCLUSION: The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation. Professional Medical Publications 2016 /pmc/articles/PMC5017114/ /pubmed/27648051 http://dx.doi.org/10.12669/pjms.324.10048 Text en Copyright: © Pakistan Journal of Medical Sciences http://creativecommons.org/licenses/by/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zulqarnain, Arif
Younas, Muhammad
Waqar, Tariq
Beg, Ahsan
Asma, Touseef
Baig, Mirza Ahmad Raza
Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title_full Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title_fullStr Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title_full_unstemmed Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title_short Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
title_sort comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017114/
https://www.ncbi.nlm.nih.gov/pubmed/27648051
http://dx.doi.org/10.12669/pjms.324.10048
work_keys_str_mv AT zulqarnainarif comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus
AT younasmuhammad comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus
AT waqartariq comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus
AT begahsan comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus
AT asmatouseef comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus
AT baigmirzaahmadraza comparisonofeffectivenessandcostofpatentductusarteriosusdeviceocclusionversussurgicalligationofpatentductusarteriosus