Cargando…
The histological and elemental characterisation of corrosion particles from taper junctions
OBJECTIVES: This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS: The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017139/ https://www.ncbi.nlm.nih.gov/pubmed/27608650 http://dx.doi.org/10.1302/2046-3758.59.2000507 |
_version_ | 1782452691954302976 |
---|---|
author | Munir, S. Oliver, R. A. Zicat, B. Walter, W. L. Walter, W. K. Walsh, W. R. |
author_facet | Munir, S. Oliver, R. A. Zicat, B. Walter, W. L. Walter, W. K. Walsh, W. R. |
author_sort | Munir, S. |
collection | PubMed |
description | OBJECTIVES: This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS: The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS: The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION: This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage. Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370–378. DOI: 10.1302/2046-3758.59.2000507. |
format | Online Article Text |
id | pubmed-5017139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
record_format | MEDLINE/PubMed |
spelling | pubmed-50171392016-09-23 The histological and elemental characterisation of corrosion particles from taper junctions Munir, S. Oliver, R. A. Zicat, B. Walter, W. L. Walter, W. K. Walsh, W. R. Bone Joint Res Hip OBJECTIVES: This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS: The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS: The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION: This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage. Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370–378. DOI: 10.1302/2046-3758.59.2000507. 2016-09-09 /pmc/articles/PMC5017139/ /pubmed/27608650 http://dx.doi.org/10.1302/2046-3758.59.2000507 Text en © 2016 Munir et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Hip Munir, S. Oliver, R. A. Zicat, B. Walter, W. L. Walter, W. K. Walsh, W. R. The histological and elemental characterisation of corrosion particles from taper junctions |
title | The histological and elemental characterisation of corrosion particles from taper junctions |
title_full | The histological and elemental characterisation of corrosion particles from taper junctions |
title_fullStr | The histological and elemental characterisation of corrosion particles from taper junctions |
title_full_unstemmed | The histological and elemental characterisation of corrosion particles from taper junctions |
title_short | The histological and elemental characterisation of corrosion particles from taper junctions |
title_sort | histological and elemental characterisation of corrosion particles from taper junctions |
topic | Hip |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017139/ https://www.ncbi.nlm.nih.gov/pubmed/27608650 http://dx.doi.org/10.1302/2046-3758.59.2000507 |
work_keys_str_mv | AT munirs thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT oliverra thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT zicatb thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walterwl thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walterwk thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walshwr thehistologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT munirs histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT oliverra histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT zicatb histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walterwl histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walterwk histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions AT walshwr histologicalandelementalcharacterisationofcorrosionparticlesfromtaperjunctions |