Cargando…

Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging

The use of a generalized sidelobe canceler (GSC) can significantly improve the lateral resolution of medical ultrasound systems, but the contrast improvement isn’t satisfactory. Thus a new Eigenspace-based generalized sidelobe canceler (EBGSC) approach is proposed for medical ultrasound imaging, whi...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jiake, Chen, Xiaodong, Wang, Yi, Li, Wei, Yu, Daoyin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017358/
https://www.ncbi.nlm.nih.gov/pubmed/27483272
http://dx.doi.org/10.3390/s16081192
_version_ 1782452729779585024
author Li, Jiake
Chen, Xiaodong
Wang, Yi
Li, Wei
Yu, Daoyin
author_facet Li, Jiake
Chen, Xiaodong
Wang, Yi
Li, Wei
Yu, Daoyin
author_sort Li, Jiake
collection PubMed
description The use of a generalized sidelobe canceler (GSC) can significantly improve the lateral resolution of medical ultrasound systems, but the contrast improvement isn’t satisfactory. Thus a new Eigenspace-based generalized sidelobe canceler (EBGSC) approach is proposed for medical ultrasound imaging, which can improve both the lateral resolution and contrast of the system. The weight vector of the EBGSC is obtained by projecting the GSC weight vector onto a vector subspace constructed from the eigenstructure of the covariance matrix, and using the new weight vector instead of the GSC ones leads to reduced sidelobe level and improved contrast. Simulated and experimental data are used to evaluate the performance of the proposed method. The Field II software is applied to obtain the simulated echo data of scattering points and circular cysts. Imaging of scattering points show that EBGSC has the same full width at half maximum (FWHM) as GSC, while the lateral resolution improves by 35.3% and 52.7% compared with synthetic aperture (SA) and delay-and-sum (DS), respectively. Compared with GSC, SA and DS, EBGSC improves the peak sidelobe level (PSL) by 23.55, 33.11 and 50.38 dB, respectively. Also the cyst contrast increase by EBGSC was calculated as 16.77, 12.43 and 26.73 dB, when compared with GSC, SA and DS, respectively. Finally, an experiment is conducted on the basis of the complete echo data collected by a medical ultrasonic imaging system. Results show that the proposed method can produce better lateral resolution and contrast than non-adaptive beamformers.
format Online
Article
Text
id pubmed-5017358
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-50173582016-09-22 Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging Li, Jiake Chen, Xiaodong Wang, Yi Li, Wei Yu, Daoyin Sensors (Basel) Article The use of a generalized sidelobe canceler (GSC) can significantly improve the lateral resolution of medical ultrasound systems, but the contrast improvement isn’t satisfactory. Thus a new Eigenspace-based generalized sidelobe canceler (EBGSC) approach is proposed for medical ultrasound imaging, which can improve both the lateral resolution and contrast of the system. The weight vector of the EBGSC is obtained by projecting the GSC weight vector onto a vector subspace constructed from the eigenstructure of the covariance matrix, and using the new weight vector instead of the GSC ones leads to reduced sidelobe level and improved contrast. Simulated and experimental data are used to evaluate the performance of the proposed method. The Field II software is applied to obtain the simulated echo data of scattering points and circular cysts. Imaging of scattering points show that EBGSC has the same full width at half maximum (FWHM) as GSC, while the lateral resolution improves by 35.3% and 52.7% compared with synthetic aperture (SA) and delay-and-sum (DS), respectively. Compared with GSC, SA and DS, EBGSC improves the peak sidelobe level (PSL) by 23.55, 33.11 and 50.38 dB, respectively. Also the cyst contrast increase by EBGSC was calculated as 16.77, 12.43 and 26.73 dB, when compared with GSC, SA and DS, respectively. Finally, an experiment is conducted on the basis of the complete echo data collected by a medical ultrasonic imaging system. Results show that the proposed method can produce better lateral resolution and contrast than non-adaptive beamformers. MDPI 2016-07-28 /pmc/articles/PMC5017358/ /pubmed/27483272 http://dx.doi.org/10.3390/s16081192 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Jiake
Chen, Xiaodong
Wang, Yi
Li, Wei
Yu, Daoyin
Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title_full Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title_fullStr Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title_full_unstemmed Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title_short Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
title_sort eigenspace-based generalized sidelobe canceler beamforming applied to medical ultrasound imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017358/
https://www.ncbi.nlm.nih.gov/pubmed/27483272
http://dx.doi.org/10.3390/s16081192
work_keys_str_mv AT lijiake eigenspacebasedgeneralizedsidelobecancelerbeamformingappliedtomedicalultrasoundimaging
AT chenxiaodong eigenspacebasedgeneralizedsidelobecancelerbeamformingappliedtomedicalultrasoundimaging
AT wangyi eigenspacebasedgeneralizedsidelobecancelerbeamformingappliedtomedicalultrasoundimaging
AT liwei eigenspacebasedgeneralizedsidelobecancelerbeamformingappliedtomedicalultrasoundimaging
AT yudaoyin eigenspacebasedgeneralizedsidelobecancelerbeamformingappliedtomedicalultrasoundimaging