Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors

Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link param...

Descripción completa

Detalles Bibliográficos
Autores principales: Schormans, Matthew, Valente, Virgilio, Demosthenous, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017394/
https://www.ncbi.nlm.nih.gov/pubmed/27527174
http://dx.doi.org/10.3390/s16081229
_version_ 1782452738028732416
author Schormans, Matthew
Valente, Virgilio
Demosthenous, Andreas
author_facet Schormans, Matthew
Valente, Virgilio
Demosthenous, Andreas
author_sort Schormans, Matthew
collection PubMed
description Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link parameters, including coil distance, alignment, shape, and load conditions. The optimum drive frequency of an inductive link varies depending on the coil spacing and load. This paper presents an optimum frequency tracking (OFT) method, in which an inductive power link is driven at a frequency that is maintained at an optimum value to ensure that the link is working at resonance, and the output voltage is maximised. The method is shown to provide significant improvements in maintained secondary voltage and system efficiency for a range of loads when the link is overcoupled. The OFT method does not require the use of variable capacitors or inductors. When tested at frequencies around a nominal frequency of 5 MHz, the OFT method provides up to a twofold efficiency improvement compared to a fixed frequency drive. The system can be readily interfaced with passive implants or implantable biosensors, and lends itself to interfacing with designs such as distributed implanted sensor networks, where each implant is operating at a different frequency.
format Online
Article
Text
id pubmed-5017394
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-50173942016-09-22 Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors Schormans, Matthew Valente, Virgilio Demosthenous, Andreas Sensors (Basel) Article Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link parameters, including coil distance, alignment, shape, and load conditions. The optimum drive frequency of an inductive link varies depending on the coil spacing and load. This paper presents an optimum frequency tracking (OFT) method, in which an inductive power link is driven at a frequency that is maintained at an optimum value to ensure that the link is working at resonance, and the output voltage is maximised. The method is shown to provide significant improvements in maintained secondary voltage and system efficiency for a range of loads when the link is overcoupled. The OFT method does not require the use of variable capacitors or inductors. When tested at frequencies around a nominal frequency of 5 MHz, the OFT method provides up to a twofold efficiency improvement compared to a fixed frequency drive. The system can be readily interfaced with passive implants or implantable biosensors, and lends itself to interfacing with designs such as distributed implanted sensor networks, where each implant is operating at a different frequency. MDPI 2016-08-04 /pmc/articles/PMC5017394/ /pubmed/27527174 http://dx.doi.org/10.3390/s16081229 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schormans, Matthew
Valente, Virgilio
Demosthenous, Andreas
Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title_full Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title_fullStr Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title_full_unstemmed Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title_short Frequency Splitting Analysis and Compensation Method for Inductive Wireless Powering of Implantable Biosensors
title_sort frequency splitting analysis and compensation method for inductive wireless powering of implantable biosensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017394/
https://www.ncbi.nlm.nih.gov/pubmed/27527174
http://dx.doi.org/10.3390/s16081229
work_keys_str_mv AT schormansmatthew frequencysplittinganalysisandcompensationmethodforinductivewirelesspoweringofimplantablebiosensors
AT valentevirgilio frequencysplittinganalysisandcompensationmethodforinductivewirelesspoweringofimplantablebiosensors
AT demosthenousandreas frequencysplittinganalysisandcompensationmethodforinductivewirelesspoweringofimplantablebiosensors