Cargando…
Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems
In this paper the extended autocorrelation velocity estimator is evaluated and compared using a nondestructive ultrasonic device. For this purpose, three velocity estimators are evaluated and compared. The autocorrelation method (ACM) is the most used and well established in current ultrasonic veloc...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017415/ https://www.ncbi.nlm.nih.gov/pubmed/27517923 http://dx.doi.org/10.3390/s16081250 |
_version_ | 1782452742764101632 |
---|---|
author | Ofuchi, César Yutaka Coutinho, Fabio Rizental Neves, Flávio de Arruda, Lucia Valéria Ramos Morales, Rigoberto Eleazar Melgarejo |
author_facet | Ofuchi, César Yutaka Coutinho, Fabio Rizental Neves, Flávio de Arruda, Lucia Valéria Ramos Morales, Rigoberto Eleazar Melgarejo |
author_sort | Ofuchi, César Yutaka |
collection | PubMed |
description | In this paper the extended autocorrelation velocity estimator is evaluated and compared using a nondestructive ultrasonic device. For this purpose, three velocity estimators are evaluated and compared. The autocorrelation method (ACM) is the most used and well established in current ultrasonic velocity profiler technology, however, the technique suffers with phase aliasing (also known as the Nyquist limit) at higher velocities. The cross-correlation method (CCM) is also well known and does not suffer with phase aliasing as it relies on time shift measurements between emissions. The problem of this method is the large computational burden due to several required mathematical operations. Recently, an extended autocorrelation method (EAM) which combines both ACM and CCM was developed. The technique is not well known within the fluid engineering community, but it can measure velocities beyond the Nyquist limit without the ACM phase aliasing issues and with a lower computational cost than CCM. In this work, all three velocity estimation methods are used to measure a uniform flow of the liquid inside a controlled rotating cylinder. The root-mean-square deviation variation coefficient (CV(RMSD)) of the velocity estimate and the reference cylinder velocity was used to evaluate the three different methods. Results show that EAM correctly measures velocities below the Nyquist limit with less than 2% CV(RMSD). Velocities beyond the Nyquist limit are only measured well by EAM and CCM, with the advantage of the former of being computationally 15 times faster. Furthermore, the maximum value of measurable velocity is also investigated considering the number of times the velocity surpasses the Nyquist limit. The combination of number of pulses and number of samples, which highly affects the results, are also studied in this work. Velocities up to six times the Nyquist limit could be measurable with CCM and EAM using a set of parameters as suggested in this work. The results validate the use of the NDT tool to measure velocities even beyond Nyquist limit by using EAM. |
format | Online Article Text |
id | pubmed-5017415 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-50174152016-09-22 Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems Ofuchi, César Yutaka Coutinho, Fabio Rizental Neves, Flávio de Arruda, Lucia Valéria Ramos Morales, Rigoberto Eleazar Melgarejo Sensors (Basel) Article In this paper the extended autocorrelation velocity estimator is evaluated and compared using a nondestructive ultrasonic device. For this purpose, three velocity estimators are evaluated and compared. The autocorrelation method (ACM) is the most used and well established in current ultrasonic velocity profiler technology, however, the technique suffers with phase aliasing (also known as the Nyquist limit) at higher velocities. The cross-correlation method (CCM) is also well known and does not suffer with phase aliasing as it relies on time shift measurements between emissions. The problem of this method is the large computational burden due to several required mathematical operations. Recently, an extended autocorrelation method (EAM) which combines both ACM and CCM was developed. The technique is not well known within the fluid engineering community, but it can measure velocities beyond the Nyquist limit without the ACM phase aliasing issues and with a lower computational cost than CCM. In this work, all three velocity estimation methods are used to measure a uniform flow of the liquid inside a controlled rotating cylinder. The root-mean-square deviation variation coefficient (CV(RMSD)) of the velocity estimate and the reference cylinder velocity was used to evaluate the three different methods. Results show that EAM correctly measures velocities below the Nyquist limit with less than 2% CV(RMSD). Velocities beyond the Nyquist limit are only measured well by EAM and CCM, with the advantage of the former of being computationally 15 times faster. Furthermore, the maximum value of measurable velocity is also investigated considering the number of times the velocity surpasses the Nyquist limit. The combination of number of pulses and number of samples, which highly affects the results, are also studied in this work. Velocities up to six times the Nyquist limit could be measurable with CCM and EAM using a set of parameters as suggested in this work. The results validate the use of the NDT tool to measure velocities even beyond Nyquist limit by using EAM. MDPI 2016-08-09 /pmc/articles/PMC5017415/ /pubmed/27517923 http://dx.doi.org/10.3390/s16081250 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ofuchi, César Yutaka Coutinho, Fabio Rizental Neves, Flávio de Arruda, Lucia Valéria Ramos Morales, Rigoberto Eleazar Melgarejo Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title | Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title_full | Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title_fullStr | Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title_full_unstemmed | Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title_short | Evaluation of an Extended Autocorrelation Phase Estimator for Ultrasonic Velocity Profiles Using Nondestructive Testing Systems |
title_sort | evaluation of an extended autocorrelation phase estimator for ultrasonic velocity profiles using nondestructive testing systems |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017415/ https://www.ncbi.nlm.nih.gov/pubmed/27517923 http://dx.doi.org/10.3390/s16081250 |
work_keys_str_mv | AT ofuchicesaryutaka evaluationofanextendedautocorrelationphaseestimatorforultrasonicvelocityprofilesusingnondestructivetestingsystems AT coutinhofabiorizental evaluationofanextendedautocorrelationphaseestimatorforultrasonicvelocityprofilesusingnondestructivetestingsystems AT nevesflavio evaluationofanextendedautocorrelationphaseestimatorforultrasonicvelocityprofilesusingnondestructivetestingsystems AT dearrudaluciavaleriaramos evaluationofanextendedautocorrelationphaseestimatorforultrasonicvelocityprofilesusingnondestructivetestingsystems AT moralesrigobertoeleazarmelgarejo evaluationofanextendedautocorrelationphaseestimatorforultrasonicvelocityprofilesusingnondestructivetestingsystems |