Cargando…

Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection

Temperature variations have significant effects on propagation of Lamb wave and therefore can severely limit the damage detection for Lamb wave. In order to mitigate the temperature effect, a temperature compensation method based on baseline signal reconstruction is developed for Lamb wave-based dam...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Guoqiang, Xiao, Yingchun, Zhang, Hua, Ren, Gexue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017438/
https://www.ncbi.nlm.nih.gov/pubmed/27529245
http://dx.doi.org/10.3390/s16081273
_version_ 1782452748051021824
author Liu, Guoqiang
Xiao, Yingchun
Zhang, Hua
Ren, Gexue
author_facet Liu, Guoqiang
Xiao, Yingchun
Zhang, Hua
Ren, Gexue
author_sort Liu, Guoqiang
collection PubMed
description Temperature variations have significant effects on propagation of Lamb wave and therefore can severely limit the damage detection for Lamb wave. In order to mitigate the temperature effect, a temperature compensation method based on baseline signal reconstruction is developed for Lamb wave-based damage detection. The method is a reconstruction of a baseline signal at the temperature of current signal. In other words, it compensates the baseline signal to the temperature of current signal. The Hilbert transform is used to compensate the phase of baseline signal. The Orthogonal matching pursuit (OMP) is used to compensate the amplitude of baseline signal. Experiments were conducted on two composite panels to validate the effectiveness of the proposed method. Results show that the proposed method could effectively work for temperature intervals of at least 18 °C with the baseline signal temperature as the center, and can be applied to the actual damage detection.
format Online
Article
Text
id pubmed-5017438
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-50174382016-09-22 Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection Liu, Guoqiang Xiao, Yingchun Zhang, Hua Ren, Gexue Sensors (Basel) Article Temperature variations have significant effects on propagation of Lamb wave and therefore can severely limit the damage detection for Lamb wave. In order to mitigate the temperature effect, a temperature compensation method based on baseline signal reconstruction is developed for Lamb wave-based damage detection. The method is a reconstruction of a baseline signal at the temperature of current signal. In other words, it compensates the baseline signal to the temperature of current signal. The Hilbert transform is used to compensate the phase of baseline signal. The Orthogonal matching pursuit (OMP) is used to compensate the amplitude of baseline signal. Experiments were conducted on two composite panels to validate the effectiveness of the proposed method. Results show that the proposed method could effectively work for temperature intervals of at least 18 °C with the baseline signal temperature as the center, and can be applied to the actual damage detection. MDPI 2016-08-11 /pmc/articles/PMC5017438/ /pubmed/27529245 http://dx.doi.org/10.3390/s16081273 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Guoqiang
Xiao, Yingchun
Zhang, Hua
Ren, Gexue
Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title_full Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title_fullStr Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title_full_unstemmed Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title_short Baseline Signal Reconstruction for Temperature Compensation in Lamb Wave-Based Damage Detection
title_sort baseline signal reconstruction for temperature compensation in lamb wave-based damage detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017438/
https://www.ncbi.nlm.nih.gov/pubmed/27529245
http://dx.doi.org/10.3390/s16081273
work_keys_str_mv AT liuguoqiang baselinesignalreconstructionfortemperaturecompensationinlambwavebaseddamagedetection
AT xiaoyingchun baselinesignalreconstructionfortemperaturecompensationinlambwavebaseddamagedetection
AT zhanghua baselinesignalreconstructionfortemperaturecompensationinlambwavebaseddamagedetection
AT rengexue baselinesignalreconstructionfortemperaturecompensationinlambwavebaseddamagedetection